Danfoss 178B2093 FCD311PT4P66EXR1D0T00C0 VLT FCD 300 Frequency Inverter

New 
On request
Refurbished   
On request
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: VLT Decentral Drive | Series: FCD 300

The Danfoss 178B2093 (model FCD311PT4P66EXR1D0T00C0) is a 1.1 kW decentralized frequency inverter belonging to the VLT Decentral Drive FCD 300 series. Designed for mounting directly on or near the motor in demanding industrial environments, this unit features a heavy-duty IP66 aluminum enclosure that eliminates the need for bulky central control panels. Operating on a 3-phase supply voltage range of 380 V AC to 480 V AC, the drive delivers a continuous output current of 3.0 A with an output frequency range from 0 Hz to 132 Hz. It is engineered for decentralized automation applications such as conveyor systems, washdown pumps, fans, and material handling machinery.

For seamless control architecture integration, the drive features a built-in PROFIBUS DP fieldbus interface supporting high-speed communication up to 12 Mbit/s, alongside an RS-485 serial interface supporting Modbus RTU and FC protocol. Its onboard control terminals include 4 programmable digital inputs, 2 analog inputs, and relay output options for status signaling and dynamic speed reference adjustments. Commissioning a replacement unit requires transferring parameter settings, which can be extracted or loaded using the optional LCP2 handheld control panel or Danfoss MCT 10 setup software. The drive contains non-volatile internal EEPROM memory capable of saving up to four independent parameter setups, facilitating fast configuration clone transfers when replacing an operational unit with support from ABC Industrial Parts.

Diagnostic feedback is provided on the front interface via dedicated status LEDs: a green BUS LED for PROFIBUS state, a yellow WARN LED for active warning conditions during operation, and a red ALARM LED for trip conditions. Additional status codes and fault history logs are accessible using the LCP2 handheld panel or MCT 10 software. Initial site checks should verify mains supply line voltages, input phase integrity, fieldbus cable connections, and active termination resistors. If an alarm condition persists immediately upon power-up without external wiring defects, or if a short circuit alarm remains active when motor cables are disconnected, internal power module hardware damage is indicated, requiring a tested exchange unit or professional repair services through ABC Industrial Parts.

Technical Specifications

ManufacturerDanfoss
Part Number178B2093
Model / TypeFCD311PT4P66EXR1D0T00C0
Product FamilyVLT Decentral Drive
SeriesFCD 300
Component TypeFrequency Inverter
Rated Power1.1 kW
Supply Voltage Range380 - 480 V AC
Continuous Output Current3.0 A
Output Frequency Range0 - 132 Hz
Enclosure RatingIP66
Integrated FieldbusPROFIBUS DP
Serial InterfaceRS-485 (Modbus RTU / FC Protocol)
Control I/O4 Digital Inputs, 2 Analog Inputs, Relay Outputs
Internal MemoryNon-volatile EEPROM (4 parameter setups)
Motor ProtectionElectronic Thermal Relay (ETR) & Ex-motor thermistor protection

Programming and Configuration

Drive parameterization and commissioning are managed using Danfoss MCT 10 setup software via the RS-485 serial port or by attaching an optional LCP2 handheld control panel. The drive's internal non-volatile EEPROM memory stores up to four complete, independent parameter setups. This multi-setup capability allows operators to store alternate operating profiles or back up production parameters directly on the drive hardware.

When deploying a replacement inverter, configuration clone files created in MCT 10 can be transferred directly to the unit. Alternatively, the pluggable LCP2 panel enables quick parameter upload from an existing drive and download to the replacement unit without needing a laptop on the factory floor. Proper parameter alignment ensures motor protection curves, digital input functions, and fieldbus communication settings match machine requirements.

Communication and System Integration

The Danfoss 178B2093 drive integrates into centralized PLC automation architectures via a built-in PROFIBUS DP fieldbus interface supporting communication speeds up to 12 Mbit/s. For point-to-point or fieldbus networking, an RS-485 serial port supports both Modbus RTU and the standard Danfoss FC protocol.

The onboard control terminals accommodate external sensors and control signals, featuring 4 programmable digital inputs, 2 analog inputs, and flexible relay outputs. The analog inputs accept speed reference signals, with configurable monitoring logic such as live zero error detection on terminal 53 or 54 to identify broken sensor wiring.

Diagnostics and Status Indication

Visual monitoring of the drive status is provided through three front-panel status LEDs. The green BUS LED indicates PROFIBUS fieldbus communication state, the yellow WARN LED signals an active warning while the drive continues running, and the red ALARM LED indicates a trip condition that halts output power.

Detailed diagnostics, active alarm codes, and fault history logs are retrievable using the pluggable LCP2 handheld keypad or through the MCT 10 setup software connected over RS-485. These tools allow maintenance technicians to isolate external line or wiring issues from internal drive hardware faults quickly.

Status LED Indicators

LEDColor/StatusMeaning
Yellow LED (WARN.)Yellow - Solid/FlashingIndicates a warning condition in the frequency converter; drive continues operating but requires attention.
Red LED (ALARM)Red - Solid/FlashingIndicates a trip or alarm condition; output power is suspended. If persistent on power-up without external cause, indicates internal hardware error.
Green LED (BUS)Green - Solid/FlashingIndicates state of the PROFIBUS fieldbus communication interface.

Replacement and Spare Part Considerations

Replacing a Danfoss 178B2093 inverter requires verifying both mechanical and electrical compatibility. The heavy-duty IP66 aluminum enclosure allows direct drop-in replacement on motor frames or nearby mounting structures. Ensure that the replacement unit shares the exact 1.1 kW rating and 380-480 V AC input specification to prevent thermal overload or line tripping.

Because the legacy VLT FCD 300 series has been succeeded by the VLT Decentral Drive FCD 302 line, maintaining identical 178B2093 spare units ensures direct physical and network replacement without altering mechanical mountings or PLC hardware configurations. Before applying power to a replacement drive, ensure the PROFIBUS node address and termination switches match the original node setup, and transfer the parameter set using an LCP2 handheld panel or MCT 10 software.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
2Live Zero ErrorSignal on input terminal 53 or 54 is below 50% of the set minimum current limit.Broken signal wire or disconnected analog sensor.Check input connections and sensor signal wiring.
4Mains Phase LossMissing phase on the AC line supply side.Blown supply fuse, missing supply phase, or supply voltage unbalance.Check supply line voltages and mains power input fuses.
7DC OvervoltageIntermediate circuit voltage exceeds the maximum limit.Motor regenerating power due to short deceleration time or high inertia load.Extend deceleration time, connect brake resistor, or enable overvoltage control.
8DC UndervoltageIntermediate circuit voltage drops below the minimum limit.Mains supply drop, power outage, or faulty input bridge.Check supply voltage and line fuses. If line voltage is correct, internal power circuit hardware fault — replace drive.
9Inverter OverloadedThermal load on the frequency converter exceeds 100% allowed limits.Continuous operation above continuous output current rating.Reduce motor load or verify drive sizing against motor power rating.
10Motor ETR OvertemperatureElectronic Thermal Relay calculated motor overtemperature.Motor running under heavy load at reduced speed for extended duration.Check motor cooling, lower load, or adjust ETR parameter settings.
11Motor Thermistor OvertemperatureMotor thermistor connected to motor protection input triggered.Motor overheated, lack of cooling, or damaged thermistor sensor.Allow motor to cool, check fan/cooling, verify thermistor wiring.
13OvercurrentPeak output current limit was exceeded.Sudden load surge, short circuit on motor output, or mechanical shock.Check motor wiring for ground fault/short circuit, check mechanical load for jamming.
14Earth FaultCurrent discharge from output phases to ground.Ground fault in output motor cable or motor windings.Check motor cable insulation and motor windings for short to ground.
16Short CircuitShort circuit between output terminals or internal inverter failure.Direct phase-to-phase short in motor wiring or defective power module (IGBT).Disconnect motor cables and test drive. If short circuit alarm persists with cables disconnected, internal hardware module failure — return unit for repair.
34HPFB Fault / Fieldbus TimeoutPROFIBUS communication timeout between PLC controller and drive.Disconnected fieldbus cable, incorrect bus termination, or invalid node address.Verify PROFIBUS cabling, active bus termination resistors, and PLC communication status.
37Phase U MissingMissing output motor phase U.Loose motor terminal connection or broken motor lead wire.Check connections between drive output terminals and motor terminal box.

Frequently Asked Questions

What software is used to program and configure the Danfoss 178B2093 drive?

The drive is configured using Danfoss MCT 10 setup software connected over the RS-485 serial port, or manually using an optional pluggable LCP2 handheld control panel. Up to four parameter setups can be stored directly in the unit's non-volatile EEPROM.

How do I transfer parameters from a failed 178B2093 drive to a replacement unit?

Parameters can be uploaded to an optional LCP2 handheld keypad or saved as a configuration file in MCT 10 software, then downloaded into the replacement inverter. Parameter extraction from non-volatile EEPROM storage can also be performed prior to commissioning.

What fieldbus protocols are supported by this VLT FCD 300 drive?

The drive features an integrated PROFIBUS DP interface supporting communication speeds up to 12 Mbit/s, as well as an RS-485 interface supporting Modbus RTU and Danfoss FC protocol.

What does a persistent Red ALARM LED on power-up indicate?

A red ALARM LED indicates a trip condition where output power is suspended. If the red LED remains illuminated upon power-up without an external cause, it indicates an internal hardware error within the frequency converter.

What action should be taken if the drive displays Fault Code 16 (Short Circuit)?

Disconnect the motor cables from the drive terminals and test the unit. If Fault Code 16 persists with motor cables disconnected, an internal power module (IGBT) failure has occurred, requiring repair or drive replacement.

Is the Danfoss 178B2093 suitable for washdown environments?

Yes, the drive is built with a robust IP66 aluminum enclosure designed for direct mounting on or near motors in harsh, dusty, or washdown industrial facilities.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.