Lenze 00355565 33.8104-E 8100 Series Frequency Inverter 2.2kW 230V

New 
On request
Refurbished   
2 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8100 Series | Series: 8100 Series

The Lenze 00355565 (model designation 33.8104-E) is a 2.2 kW AC frequency inverter engineered for precise motor speed control within the Lenze 8100 Series. Powered by either a single-phase or three-phase 230 V AC supply (180 to 264 V AC), the drive provides a three-phase output up to 9.5 A continuous current across an adjustable output frequency range of 0 to 480 Hz. Housed in an IP20 enclosure, the 33.8104-E integrates a Class E EMC filter that provides internal radio interference suppression to meet European electromagnetic compatibility requirements without requiring external filter modules.

Integration into automated machinery relies on terminal I/O combined with serial communication options. The drive features four programmable digital inputs, one digital status output, a multi-function analog input (0–10 V or 0–20 mA), and one analog output (0–10 V). To put a spare inverter into service, operational parameters stored in non-volatile EEPROM memory must be matched to the system using front keypad programming or transferred via Lenze Global Drive Control (GDC) software over an optional LECOM-A (RS232 module 2102IB / 33.2102) or LECOM-B (RS485) module. ABC Industrial Parts supports parameter backup extraction and spare-part commissioning to ensure smooth replacement in operating production lines.

System status monitoring and fault isolation are handled via an onboard 4-digit 7-segment LED display, which shows operational frequency, parameter numbers, and active TRIP error codes. Fault codes indicate specific trip conditions such as power stage short circuits (OC1), ground faults (OC2), overloads (OC5), DC link overvoltage (OU), DC link undervoltage (LU), heat sink overtemperature (OH), and serial communication faults (CE0). Initial troubleshooting involves verifying line voltages, checking motor insulation, cleaning heat sink cooling fins, and validating interface connections. When power stage or internal controller failures occur, field repair is not feasible, making a fully tested replacement or repair through ABC Industrial Parts the most practical solution to restore operation.

Technical Specifications

ManufacturerLenze
Part Number00355565
Model / Type33.8104-E
Product Family8100 Series
Component TypeFrequency Inverter
Rated Power2.2 kW
Supply Voltage230 V AC
Supply Voltage Range180 - 264 V AC
Output Voltage230 V AC
Output Current9.5 A
Output Frequency Range0 - 480 Hz
Control MethodV/f Control
Integrated EMC FilterBuilt-in Class E Filter
Digital Inputs4
Digital Outputs1
Analog Inputs1 (0-10 V / 0-20 mA)
Analog Outputs1 (0-10 V)
Protection RatingIP20

Programming and Configuration

Parameterization of the Lenze 00355565 inverter is executed directly using the front keypad or through Lenze Global Drive Control (GDC) software. Key configurable parameters include V/f characteristic curve selection (linear or quadratic), slip compensation, torque boost, acceleration/deceleration ramp times, and terminal I/O assignments.

The drive utilizes non-volatile EEPROM memory to preserve parameter configurations permanently, even during power interruptions. When installing a replacement unit, parameter sets can be entered manually via the keypad or extracted and uploaded via GDC software to ensure identical operation to the original drive.

Communication and System Integration

The 33.8104-E frequency inverter integrates with control hardware through dedicated control terminals and serial interface accessories. Hardwired control relies on four programmable digital inputs, one digital status output, a multi-function analog input (0–10 V or 0–20 mA), and an analog output (0–10 V).

To enable network integration or software diagnostics, optional plug-in communication adapters are available. The LECOM-A RS232 module (2102IB / 33.2102) connects directly to diagnostic computers, while the LECOM-B RS485 adapter supports multi-drop serial networking with supervisory PLCs and host controllers.

Diagnostics and Status Indication

Real-time operational monitoring is provided by the integrated 4-digit 7-segment display located on the front panel. During standard operation, the display outputs the active output frequency and selected parameter values. When a fault occurs, the display automatically switches to display active TRIP codes for rapid error identification.

Status LED Indicators

LEDColor/StatusMeaning
4-digit 7-segment LED displayActive DisplayDisplays output frequency, current parameter numbers/values, and active TRIP error codes.

Replacement and Spare Part Considerations

When replacing a Lenze 00355565 drive, verify that the replacement match matches the 33.8104-E model designation. It is vital to confirm the 2.2 kW power rating, 9.5 A current output, 230 V AC supply range, and the Class E filter designation to ensure compliance with system wiring and EMC standards.

Replacement drives are not plug-and-play. Parameter settings stored in the original unit's EEPROM memory must be loaded into the spare drive before running the motor. If the faulty unit allows communication, parameter sets can be downloaded using Global Drive Control software via a LECOM adapter; otherwise, parameter parameters must be manually entered according to machine records.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuitShort circuit on motor output or earth fault detected during operation or acceleration.Short circuit in motor winding or motor cable, insulation breakdown to ground.Check motor cable and motor insulation resistance. If fault occurs without motor connected, internal power stage is damaged and unit must be returned for repair or replaced.
OC2Earth faultGround fault on motor side.Motor cable or motor winding has ground contact.Check motor cabling and motor for ground faults.
OC5Overload / I x t limitationDrive current overload threshold exceeded.Acceleration time too short, motor mechanically overloaded or blocked.Increase acceleration time, reduce load, check motor sizing.
OUDC link overvoltageDC bus voltage exceeds maximum limit.Deceleration time too short, excessive regenerative energy from motor, supply voltage too high.Extend deceleration time, fit external brake module/resistor, check line voltage.
LUDC link undervoltageDC bus voltage dropped below minimum threshold.Mains supply voltage too low, phase failure, power interruption.Check mains line voltage, line fuses, and wiring connections.
OHHeat sink overtemperatureHeat sink temperature exceeded limit (> 85 °C).Ambient temperature too high, cooling fan defective or clogged, insufficient clearance.Clean heat sink fins, check cooling fan, ensure adequate cabinet ventilation.
OH4Motor overtemperatureMotor thermistor (PTC) triggered.Motor overloaded, motor cooling insufficient.Allow motor to cool down, reduce load, check motor ventilation.
EErEEPROM memory faultChecksum error in non-volatile parameter memory.EEPROM corruption or hardware failure.Perform factory parameter reset. If fault persists, non-volatile memory hardware failure requires unit repair or replacement.
ErControl electronics errorInternal hardware or micro-controller fault.Internal electronic component failure.Cycle mains power. If fault persists, internal hardware defect requires returning unit for service or replacement.
LPMains phase failureLoss of one phase on AC input supply.Blown fuse on input phase, loose supply wire.Check input power fuses and line supply wiring.
CE0Communication errorInterruption in serial LECOM interface communication.Communication cable disconnected, baud rate error, master offline.Check LECOM cable connections, baud rate parameters, and master controller status.

Frequently Asked Questions

How are parameters transferred to a replacement Lenze 00355565 inverter?

Parameters can be entered manually using the keypad or downloaded electronically using Lenze Global Drive Control (GDC) software via a LECOM-A (RS232) or LECOM-B (RS485) communication module. Settings are saved in non-volatile EEPROM memory.

What does the -E suffix signify in the model number 33.8104-E?

The -E suffix signifies that the drive contains an integrated Class E EMC filter, providing internal radio interference suppression without requiring external filter components.

What causes an OC1 fault code and how should it be resolved?

An OC1 fault indicates a short circuit or earth fault on the motor output. Inspect motor cables and winding insulation. If the OC1 code persists with the motor disconnected, internal power stage damage is present, requiring repair or drive replacement.

What AC supply voltage range does the 33.8104-E support?

The inverter accepts single-phase or three-phase 230 V AC input across an operational range of 180 V AC to 264 V AC.

Which software and communication modules are used for PC connection?

Lenze Global Drive Control (GDC) software is used for PC parameterization. Physical connection is made using either the LECOM-A RS232 module (2102IB / 33.2102) or the LECOM-B RS485 adapter.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.