Lenze 00375586 33.8218-E Keypad Operating Module

New 
On request
Refurbished   
2 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 / 9300 Inverter Accessories | Series: 8200 / 9300 Series

The Lenze 00375586 keypad operating module, model 33.8218-E, is an operator interface unit designed for parameterization, local control, and diagnostic monitoring of Lenze frequency inverters. Built for use across multiple Lenze drive families—including the 8200 series, 8200 vector series, 8200 motec, and 9300 series drive controllers—this module provides direct physical access to inverter parameters without external interfaces. It mounts directly into the host drive's front panel slot via a multi-pin direct plug connector, establishing serial communication and drawing operational power directly from the inverter controller.

Putting a replacement keypad into service is a straightforward procedure due to its plug-and-play slot mounting design. The 33.8218-E contains non-volatile internal EEPROM memory capable of storing one full drive parameter set. This integrated memory enables service engineers to back up parameter configurations from an active inverter and clone them directly to a donor or replacement drive without requiring programming software, external PC links, or interface cables. When commissioning a spare drive or migrating settings, parameter extraction directly through the keypad simplifies machine restoration. Technical guidance from ABC Industrial Parts can help maintenance teams verify drive compatibility and source reliable tested replacement units.

For daily operation and troubleshooting, the module features a clear LCD display that provides real-time visibility into key operating parameters, including output frequency, motor current, and DC bus voltage. Technicians can navigate the keypad menu to inspect operational states such as IMP and RUN, as well as historical TRIP fault codes. When fault conditions occur—such as short circuits (OC1), DC overvoltage (OU), or communication faults (CE0)—the LCD displays the exact code for fast diagnosis. If a CE0 communication error arises, re-seating the module and checking interface connector contacts is recommended before considering hardware repair or unit replacement via ABC Industrial Parts.

Technical Specifications

ManufacturerLenze
Part Number00375586
Model / Type33.8218-E
Component TypeKeypad Operating Module
Product Family8200 / 9300 Inverter Accessories
Display TypeLCD display
Mounting TypePlug-in front panel interface slot
Host InterfaceMulti-pin direct plug connector
Parameter Memory Capacity1 parameter set
Memory TechnologyInternal EEPROM

Programming and Configuration

The Lenze 00375586 (33.8218-E) operating module allows direct parameterization and local drive setup using its integrated keypad menu. Maintenance personnel can adjust drive parameters, speed setpoints, acceleration/deceleration ramps, and operational modes directly at the drive without connecting an external PC or running engineering software.

Featuring an internal non-volatile EEPROM, the keypad holds one complete inverter parameter set. This built-in memory enables fast drive cloning by allowing users to upload a parameter profile from a running drive and download it directly into a replacement drive controller on the plant floor.

Communication and System Integration

The 33.8218-E keypad operating module establishes direct serial communication with the host drive controller via a multi-pin connector on the rear of the module. Inserting the module into the front interface slot of the inverter creates an immediate mechanical and electrical connection.

Power for the keypad is supplied directly by the drive controller through the interface connector. The module is fully compatible across a wide spectrum of drive families, including Lenze 8200 series, 8200 vector series, 8200 motec, and 9300 series drive controllers.

Diagnostics and Status Indication

The integrated LCD display serves as the primary diagnostic tool, presenting real-time operational data such as output frequency, motor current, and DC link voltage. Drive operating states, including pulse inhibit (IMP) and normal running state (RUN), are displayed clearly during drive operation.

Technicians can access the fault history menu through the keypad controls to review active and historical TRIP codes. This diagnostic readout simplifies identifying root causes for drive shutdowns and system trips.

Replacement and Spare Part Considerations

When swapping a host drive or replacing an operating module, utilizing the keypad's internal EEPROM parameter backup ensures that exact operational settings—such as ramps, limits, and fieldbus configurations—are preserved without manual re-entry.

Ensure that the multi-pin connector on the rear of the keypad and the front slot on the drive controller are clean and free of physical damage prior to installation. Firm seating ensures proper pin contact and prevents communication failures such as code CE0.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuit / OvercurrentShort circuit on motor output or severe overcurrent conditionShort circuit in motor cable, motor winding fault, acceleration time set too shortCheck motor and motor cable for short circuits/earth faults; check drive ramp settings
OC2Earth faultGround fault on output phaseEarth fault in motor cable or motor insulation failureCheck insulation resistance of motor and connecting cable
OC5Ixt overloadDrive continuous overload limit exceededExcessive mechanical load, motor size mismatched to driveReduce mechanical load, verify motor sizing and acceleration parameters
OUOvervoltage DC linkDC bus voltage exceeded maximum allowable thresholdExcessive regenerative energy from motor during deceleration, deceleration time too shortIncrease deceleration time or install braking resistor / brake chopper
LUUndervoltage DC linkDC bus voltage fell below lower operating limitMains supply voltage too low, line phase failure, main power supply interruptionCheck mains voltage input and line fuses/fusing
OHHeatsink overtemperatureDrive heatsink temperature exceeded maximum safety thresholdInadequate cooling, fan failure, ambient temperature too high, clogged heat sinkClean heatsink fins, verify control cabinet ventilation and fan function
OH4Motor overtemperatureMotor thermistor / PTC sensor triggered overtemperature signalMotor overload, insufficient motor cooling at low speedsCheck motor loading and forced cooling fan operation
EEREEPROM faultInternal EEPROM memory read/write failureEEPROM checksum error, hardware memory corruptionReload factory default settings; if fault persists, replace drive controller unit
CE0Communication errorCommunication breakdown between keypad/option module and drive controllerLoose connector contact, damaged keypad socket or corrupted serial busRe-seat keypad operating module in drive slot; inspect pins for damage

Frequently Asked Questions

How do I duplicate parameter settings between drives using the 00375586 keypad?

The keypad contains an internal EEPROM memory that holds one full drive parameter set. You can save the configuration from an active drive into the keypad memory and then transfer it directly into another drive without using external software or cables.

Which drive families support the Lenze 33.8218-E keypad?

The module is compatible with Lenze 8200 series, 8200 vector series, 8200 motec, and 9300 series drive controllers.

What does fault code CE0 mean on the keypad display?

Code CE0 indicates a communication failure between the keypad module and the drive controller. This is typically caused by a loose connection or damaged contacts in the front interface slot.

Does the 00375586 module require a separate power supply or cable?

No. The keypad inserts directly into the front panel interface slot of the inverter using its multi-pin connector and draws power directly from the host drive.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.