The Lenze 00386351 (type EVF8102-A, ordering designation 33.8102A.2A.60) is a compact 0.75 kW frequency inverter from the Lenze 8100 Series, engineered for speed regulation of standard three-phase AC induction motors. Designed for cabinet panel mounting, this drive operates on a single-phase or three-phase 230 V AC mains connection within an acceptable voltage window of 180 V AC to 264 V AC. It provides a continuous output current of 4.0 A at 230 V AC, supporting motor output frequencies from 0 Hz up to 480 Hz with an adjustable switching frequency up to 8 kHz to minimize motor noise. The drive is widely deployed across packaging machinery, material handling systems, textile equipment, conveyor drives, pumps, fans, and machine tool spindles.
Control integration is supported by four programmable digital inputs, one transistor digital output, one analog setpoint input supporting 0-10 V or 0/4-20 mA signals, and one 0-10 V analog monitor output. Built-in network connectivity is expandable via a dedicated communication slot that accepts modular LECOM fieldbus adapters for RS232, RS485, or fiber optic interfaces. Commissioning a spare drive requires restoring the application parameter set stored in non-volatile internal EEPROM memory. Parameter transfers and drive setup can be accomplished using the plug-in EMF2101IB operating keypad module or Lenze Global Drive Control (GDC) engineering software. ABC Industrial Parts can assist maintenance teams with pre-tested replacement units and parameter backup migration to minimize installation downtime.
Front-panel status LEDs provide immediate operational status, featuring a green LED for mains voltage and drive readiness alongside a red TRIP LED indicating active fault states. Detailed diagnostic codes and parameter monitoring are accessible through the optional EMF2101IB keypad or via GDC software over a LECOM communication link. Recommended maintenance checks include verifying mains voltage, checking motor winding resistance and cable insulation, ensuring heatsink airflow, and inspecting fieldbus cabling. Persistent hardware faults or unrecoverable EEPROM checksum errors require specialized repair or unit exchange, where ABC Industrial Parts provides efficient replacement options to keep production lines running.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | 00386351 |
| Model / Type | EVF8102-A (33.8102A.2A.60) |
| Product Family | 8100 Series |
| Component Type | Frequency Inverter |
| Rated Power Output | 0.75 kW |
| Nominal Supply Voltage | 230 V AC (1-phase / 3-phase) |
| Supply Voltage Range | 180 V AC to 264 V AC |
| Continuous Output Current | 4.0 A |
| Output Voltage Range | 0 to 230 V AC |
| Output Frequency Range | 0 Hz to 480 Hz |
| Maximum Switching Frequency | 8 kHz |
| Digital Inputs | 4 programmable |
| Digital Outputs | 1 transistor output |
| Analog Inputs | 1 (0-10 V or 0/4-20 mA) |
| Analog Outputs | 1 (0-10 V) |
Programming and Configuration
Parameterization of the Lenze 00386351 EVF8102-A frequency inverter is carried out using Lenze Global Drive Control (GDC) software or the optional EMF2101IB plug-in keypad module. Operating parameters control motor acceleration ramps, current limits, switching frequency adjustments up to 8 kHz, and I/O signal mapping. Drive configurations are held securely in non-volatile internal EEPROM memory, safeguarding parameters against power supply loss.
When commissioning a spare inverter, the stored parameter set must be transferred to match the operational settings of the driven equipment. Users can upload parameter files via GDC software using a LECOM communication adapter or directly save and copy parameters using the memory function on the EMF2101IB operating keypad module. This eliminates manual parameter entry and reduces replacement errors.
Communication and System Integration
The EVF8102-A provides onboard hardwired control terminals and a modular communication slot for direct integration into machine control architectures. Physical connections include four digital inputs, one digital transistor output, one analog setpoint input supporting voltage (0-10 V) or current (0/4-20 mA) modes, and one 0-10 V analog monitor output.
For serial fieldbus communications, the dedicated interface slot accommodates LECOM modular communication adapters. Depending on the installed LECOM module, the drive can interface over RS232, RS485, or optical fiber communication lines, enabling direct connections to higher-level controllers or monitoring PCs running Global Drive Control software.
Diagnostics and Status Indication
The front face of the EVF8102-A frequency inverter features status LEDs for quick visually accessible system status checks. A solid green Ready/Mains LED indicates that mains voltage is present within the valid 180 V to 264 V AC operating window and the inverter is ready for operation. A solid red Fault (TRIP) LED indicates that an active protection or fault condition has triggered a drive shutdown.
Detailed fault codes and operational diagnostics can be monitored using the plug-in EMF2101IB keypad module or via LECOM communication connected to GDC software. Transistor and relay trip outputs can also be wired to upstream controllers to signal fault states automatically.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Ready / Mains | Green - Solid | Mains voltage present and drive is ready for operation |
| Fault (TRIP) | Red - Solid | Drive active fault condition detected |
Replacement and Spare Part Considerations
When selecting a spare unit for the Lenze 00386351 EVF8102-A drive, match both the part number 00386351 and model type EVF8102-A (or 33.8102A.2A.60) to ensure exact mechanical and electrical interchangeability. Confirm that the replacement drive rated output matches 0.75 kW and 4.0 A continuous output current.
Because the EVF8102-A relies on stored configuration parameters in EEPROM memory, a replacement drive will not operate correctly out of the box without parameter transfer. Always backup settings from the failed unit using the EMF2101IB keypad or Global Drive Control software prior to decommissioning, then download the backup file into the replacement inverter.
While Lenze has introduced modern drive families such as the i510 and i550 series as long-term replacement paths, utilizing an exact Lenze 8100 Series replacement drive avoids control cabinet retrofits, rewiring, or PLC communication modifications.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short circuit | Short circuit on motor side or excessive acceleration current | Short circuit in motor cable, short circuit in motor windings, acceleration time set too short | Check motor and motor cables for short circuit or earth fault; increase acceleration ramp time. |
| OC2 | Earth fault | Ground fault detected on inverter output | Earth fault in motor cable or motor, excessive cable capacitance | Check motor cable insulation and motor winding resistance to ground. |
| OU | Overvoltage | DC bus overvoltage | Regenerative energy from motor during deceleration too high, deceleration ramp time set too short, mains voltage too high | Increase deceleration ramp time; check mains voltage; connect braking transistor/resistor if supported. |
| LU | Undervoltage | DC bus voltage dropped below minimum threshold | Mains supply voltage too low, supply power fault, mains phase loss | Check mains voltage and line fuses. |
| OH | Heatsink overtemperature | Inverter heatsink temperature exceeds limit | Ambient temperature too high, cooling fan failure, blocked heatsink, continuous overload | Clean heatsink, ensure adequate cabinet ventilation, reduce load or switching frequency. |
| OFL | Motor Overload | Motor overload condition detected (I2t limitation active) | Mechanical overload on motor, incorrect motor parameter settings | Check motor load and drive dimensioning; verify motor current setting. |
| CE | Communication error | Interrupted communication on fieldbus interface | Loose connector, damaged cable, baud rate mismatch, missing termination | Check serial connection cable, interface module seating, and bus parameter settings. |
| EE | EEPROM error | Internal non-volatile memory checksum fault | Electrical interference during parameter write operation, internal hardware defect | Perform factory reset and reload parameters. If error persists, internal hardware fault — return unit for repair. |
Frequently Asked Questions
What tools are needed to program a replacement Lenze 00386351 EVF8102-A inverter?
Programming can be completed using Lenze Global Drive Control (GDC) software via a LECOM adapter (RS232, RS485, or fiber optic) or directly at the drive using an optional EMF2101IB plug-in keypad module.
Can the EVF8102-A drive accept both 1-phase and 3-phase mains input?
Yes, the EVF8102-A accepts either single-phase or three-phase 230 V AC mains input within an allowable voltage range of 180 V AC to 264 V AC.
How are parameter settings transferred from a failed drive to a replacement unit?
Parameter sets stored in non-volatile EEPROM memory can be copied into an EMF2101IB keypad module and downloaded directly onto the new unit, or saved and restored electronically using Global Drive Control (GDC) software.
What does fault code EE mean on the Lenze EVF8102-A display?
Fault code EE indicates an EEPROM checksum memory fault, caused by electrical noise during parameter saving or internal component failure. If clearing the fault and reloading parameters fails, internal hardware damage has occurred.
What fieldbus module options fit into the EVF8102-A communication slot?
The dedicated communication slot accepts modular LECOM interfaces supporting serial communications over RS232, RS485, or optical fiber cables.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.