Lenze 00399420 EVD4906-E Frequency Inverter Drive

New 
On request
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: EVD4900 Series | Series: EVD4900 Series

The Lenze 00399420, model EVD4906-E, is a 7.5 kW frequency inverter drive controller within the Lenze EVD4900 Series designed for precise speed, torque, and positioning control of three-phase AC motors. Operating across a mains voltage input range from 320 V AC to 550 V AC, this unit delivers a rated continuous output current of 16.5 A at 400 V AC with an output frequency range up to 480 Hz. Housed in an IP20 rated enclosure intended for vertical panel mounting inside electrical control cabinets, the drive provides dynamic motor regulation across automated packaging machinery, material handling conveyors, and industrial processing equipment.

For communication and motion synchronization, the EVD4906-E comes equipped with an integrated onboard CAN system bus interface alongside a modular expansion slot supporting option modules such as LECOM 2102IB/2111IB for RS-232, RS-485, or fiber-optic links, or PROFIBUS-DP module 2131IB. Placing a spare unit into service requires transferring device parameters, as drive settings stored in internal EEPROM memory must align with the target machine's operational requirements. Parameter backup and restoration can be completed using Lenze Global Drive Control (GDC) PC software or a pluggable 4900 series operating keypad. Maintenance teams often turn to ABC Industrial Parts for pre-tested spare drives and parameter transfer assistance to minimize production downtime.

Diagnostic monitoring is provided directly on the front panel through status LEDs: a solid Green LED indicates power stage operational readiness, while a Red LED signals an active TRIP fault condition. Detailed status reporting and historical fault logging are accessible through GDC software or keypad parameters C008 (TRIP fault memory) and C018 (actual status), as well as via a digital TRIP status relay output. When fault conditions such as an OC1 overcurrent fault or H05 internal hardware error persist after verifying motor insulation and external wiring, internal power stage or control board damage is indicated. In cases where field servicing is not possible, sourcing a tested replacement module through ABC Industrial Parts ensures a quick return to full operation.

Technical Specifications

ManufacturerLenze
Part Number00399420
Model / TypeEVD4906-E
Product FamilyEVD4900 Series
Component TypeFrequency Inverter Drive Controller
Rated Power Output7.5 kW
Rated Output Current16.5 A
Supply Voltage Range320 V AC - 550 V AC
Output Voltage400 V AC
Max Output Frequency480 Hz
Switching Frequency8 kHz
Integrated Fieldbus InterfaceSystem Bus (CAN)
Enclosure RatingIP20
Mounting TypeControl Cabinet Panel Mount

Programming and Configuration

Configuring the Lenze 00399420 EVD4906-E drive controller relies on Lenze Global Drive Control (GDC) software or a pluggable 4900 series operating keypad. Through the GDC PC interface, commissioning engineers can adjust parameter settings, create drive backups, and observe real-time operational variables. Adjusted parameter values are saved directly into the onboard EEPROM storage, preserving configuration settings when control power is cycled.

Specific keypad code parameters facilitate system setup, parameter transfer, and system resets. Parameter C002 resets the inverter to factory default values, while parameter C003 executes a manual parameter write to the EEPROM. Diagnostic code C018 provides continuous display of live operating status, and parameter C008 records the TRIP fault log to aid in systematic system troubleshooting.

Communication and System Integration

The EVD4906-E model variant features an integrated onboard CAN system bus interface designed for high-speed multi-axis motion synchronization. Operating without requiring extra communication modules, this built-in bus enables peer-to-peer inter-drive synchronization across multi-axis automated packaging machinery and conveyor systems.

For higher-level network integration, the drive controller includes an expansion slot accommodating various plug-in communication modules. Supported options include Lenze LECOM modules 2102IB and 2111IB for RS-232, RS-485, or fiber-optic connections, as well as the PROFIBUS-DP module 2131IB. Integrating these modules requires setting node addresses, confirming proper bus termination resistors, and ensuring correct cable shield grounding.

Diagnostics and Status Indication

Real-time diagnostic feedback on the Lenze EVD4906-E is provided by onboard front status LEDs, a digital TRIP relay output, and internal parameter monitoring tools. A solid Green LED indicates that the drive power stage is active and ready for operation, whereas a Red LED illuminates or flashes during an active TRIP fault condition. The TRIP relay output triggers immediately upon a drive fault to alert master control systems.

Comprehensive diagnostic routines can be conducted using Lenze GDC software or the operating keypad. Keypad parameter C008 stores historical TRIP fault events for review, while parameter C018 provides real-time status code readouts to help identify issues ranging from mains undervoltage to communication timeouts.

Status LED Indicators

LEDColor/StatusMeaning
Red LED (TRIP / Error)Red - Illuminated or FlashingDrive fault condition or active TRIP
Green LED (Ready / Operation)Green - SolidNormal drive ready state / power stage active

Replacement and Spare Part Considerations

When replacing an existing drive, verify that the replacement part number matches 00399420 and carries the exact EVD4906-E model designation. The '-E' suffix identifies the inclusion of the onboard CAN system bus interface, which is required for applications utilizing inter-drive synchronization across multi-axis production equipment.

A replacement EVD4906-E drive is not pre-configured out of the box and requires parameter transfer before operating the machine. Parameter profiles stored on the original unit must be backed up using Lenze GDC software or an operating keypad, written to the replacement unit, and permanently stored to EEPROM using keypad code C003. Any installed LECOM or PROFIBUS-DP expansion modules must be transferred to the spare unit, and node address settings and fieldbus termination must be verified prior to applying line power.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuit / Earth faultInstantaneous overcurrent during power-up or operation due to motor short circuit or earth fault.Short circuit in motor cable, motor winding fault, earth fault, or internal inverter power stage defect.Check motor and wiring for short circuits and insulation faults. If motor and cable are intact, internal hardware failure requires repair or unit replacement.
OC2Overcurrent during accelerationDrive exceeded maximum current threshold while accelerating.Acceleration time too short, motor too large, mechanical blockage or binding.Increase acceleration time, check mechanical load for binding, verify motor parameters.
OC5Overload during constant operationContinuous motor overload during steady-state operation.Mechanical overload, motor undersized, incorrect V/f or current limit parameter settings.Reduce mechanical load, verify motor sizing and parameter values.
OUOvervoltage in DC busDC bus voltage exceeds maximum upper safety limit.Excessive regenerative energy during deceleration, deceleration time too short, brake resistor open or missing.Extend deceleration time, install or check dynamic braking resistor and chopper.
LUUndervoltage in DC busDC bus voltage dropped below minimum operating threshold.Mains supply failure, supply phase loss, input line voltage too low, blown input fuse.Check AC supply line voltage, fuses, contactors, and input connections.
OHHeatsink overtemperatureDrive heat sink temperature exceeded maximum safe operating threshold.Insufficient cabinet cooling, cooling fan failure, heatsink fins clogged with dirt, ambient temperature too high.Clean heat sink, check cabinet ventilation and cooling fan function, reduce ambient temperature.
OH4Motor thermal overload (I2t)Calculated thermal overload of the motor based on continuous current monitoring.Motor operated at high load at low speed without external cooling, continuous overload.Allow motor to cool, check motor loading, verify I2t motor protection parameter settings.
CE0 / C009Communication error / System bus errorLoss of fieldbus or system bus communication timed out.Bus cable disconnected, termination missing, incorrect node address, master device offline.Check CAN / system bus wiring, shield grounding, termination resistors, and master controller status.
EErEEPROM memory faultChecksum or read/write failure in internal EEPROM parameter storage.Power interruption during parameter save operation, internal EEPROM failure.Reload factory default parameters (C002) and write parameters back to EEPROM (C003). If fault persists, replace unit (internal hardware failure).
H05Internal hardware faultInternal control board self-test or microcontroller error.Internal electronic failure, board degradation.Cycle power to reset. Internal hardware fault requiring factory service or unit replacement.

Frequently Asked Questions

What is the continuous power and current rating of the Lenze 00399420 drive?

The Lenze 00399420 (model EVD4906-E) is rated for 7.5 kW continuous power output with a continuous output current of 16.5 A at 400 V AC.

How are parameter settings transferred to a replacement EVD4906-E drive?

Parameter settings can be backed up and transferred using Lenze Global Drive Control (GDC) PC software or a pluggable 4900 series operating keypad. Once loaded on the new drive, parameters must be saved to EEPROM using keypad code C003.

What fieldbus and communication interfaces does the Lenze EVD4906-E support?

The EVD4906-E features a built-in onboard CAN system bus interface. It also includes an expansion slot supporting plug-in LECOM modules (2102IB / 2111IB) for RS-232, RS-485, or fiber optics, as well as the PROFIBUS-DP module 2131IB.

What do the status LEDs on the Lenze 00399420 drive indicate?

A solid Green LED indicates that the drive power stage is active and ready for operation. An illuminated or flashing Red LED signals an active TRIP fault condition or drive error.

What action should be taken if the drive displays an OC1 fault code?

An OC1 code indicates an instantaneous overcurrent or short circuit. Inspect the motor and field wiring for short circuits or earth faults. If external components are intact, an OC1 error points to an internal power stage failure requiring unit repair or replacement.

What input supply voltage range is supported by the Lenze 00399420 drive?

The drive operates on a wide three-phase AC input voltage range from 320 V AC to 550 V AC.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.