Lenze 00411352 EVF8213-E 8200 Vector Frequency Inverter
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze 00411352 EVF8213-E is a 5.5 kW frequency inverter from the Lenze 8200 vector product family, engineered to deliver precise speed and torque regulation for three-phase AC induction motors. Operating across an input voltage range of 320 V AC to 528 V AC, this AC drive delivers a rated continuous output current of 13 A at an 8 kHz default switching frequency and can handle temporary dynamic loads up to 19.5 A, representing a 150% overload capacity for 60 seconds. Equipped with an integrated Class A/B radio frequency interference filter designated by the -E suffix, the unit provides effective electromagnetic compatibility without requiring additional external line filters inside the control cabinet.
Interfacing the EVF8213-E into an existing machine installation relies on its modular plug-in architecture, which accommodates various 8200 vector function modules for digital and analog I/O or fieldbus communication. To put a replacement drive into service, operational parameter sets must be loaded into the drive non-volatile EEPROM memory, which stores up to four complete configurations. System commissioning and parameter transfer can be executed using Lenze Global Drive Control software or via the plug-in E82ZTK XT Keypad module, which allows keying in values or duplicating parameters directly between drives. When replacing an existing unit in a machine control panel, technical personnel can migrate saved parameter files and swap the plug-in function module, while ABC Industrial Parts can support speed-critical parameter extraction or replacement hardware preparation.
System status and drive conditions are monitored through front cover and function module LEDs, where solid or flashing green indicates normal operation and red indicates active error states. Detailed fault information is made available through the drive fault history register, accessible using the XT Keypad readout or PC-based diagnostics in Global Drive Control software. Fault indications cover critical operating events such as motor short circuits (OC1), ground leaks (OC2), DC bus overvoltage (OU), undervoltage (LU), and internal hardware errors (H10). While external issues like cabling short circuits, load blockages, or improper deceleration ramps can be resolved directly on the machine line, internal control board or power component failures require bench-level service, where ABC Industrial Parts provides tested exchange drives or repair options to restore production promptly.
Technical Specifications
| Rated Power | 5.5 kW |
| Supply Voltage Range | 320 - 528 V AC |
| Rated Output Current | 13 A |
| Maximum Output Current | 19.5 A |
| Switching Frequency | 8 kHz |
| Output Frequency Range | 0 - 480 Hz |
| Overload Capacity | 150% for 60 seconds |
| Control Method | V/f linear, V/f quadratic, sensorless flux-vector control |
| Integrated EMC Filter | Class A/B RFI Filter (-E designation) |
| Supported Protocols | CANopen, PROFIBUS-DP, INTERBUS, DeviceNet, RS232/RS485 (via optional function modules) |
Programming and Configuration
The Lenze 00411352 EVF8213-E frequency inverter features structured parameter management designed for fast setup and flexible drive control. Up to four complete parameter sets can be stored internally within non-volatile EEPROM memory, enabling a single inverter to execute multiple predefined operating profiles or motor control schemes without requiring external reprogramming.
Drive configuration and commissioning are carried out using the PC-based Lenze Global Drive Control software suite or through the optional plug-in E82ZTK XT Keypad module. Global Drive Control software connects via serial communication interfaces to provide diagnostic monitoring, parameter editing, and offline project archiving. Alternatively, the XT Keypad plugs directly onto the front interface of the inverter to provide a clear readout for local parameter modification and direct parameter copy functionality between identical drive units.
Communication and System Integration
Designed around a flexible modular concept, the Lenze 00411352 EVF8213-E integrates into modern industrial automation architectures using plug-in function modules from the 8200 vector series. The underlying drive hardware accommodates standard fieldbus interfaces, enabling seamless networking with higher-level programmable logic controllers and industrial network masters.
Supported communication protocols include CANopen, PROFIBUS-DP, INTERBUS, DeviceNet, and serial RS232 or RS485 LECOM interfaces. Dedicated communication modules, such as the Lenze E82ZAFCC for CANopen and the E82ZAFPC for PROFIBUS-DP, attach directly to the front slot of the drive. This modularity allows technicians to adapt or swap network interfaces without altering the main power terminal wiring or base inverter chassis.
Diagnostics and Status Indication
Drive condition and active system states on the Lenze 00411352 EVF8213-E are monitored via status LEDs on the front cover and installed function modules. Green LED illumination signifies steady operational state or active runtime, while red LED indications signal active error conditions, trips, or protective shutdowns.
For detailed diagnostics, the inverter maintains an internal fault history register that records specific error trip codes alongside corresponding operating metrics at the time of the event. System operators and technicians can view these diagnostic trip records using the E82ZTK XT Keypad module or by establishing a diagnostic connection with Lenze Global Drive Control software on a PC.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Front Cover / Function Module LEDs | Red / Green - Solid / Flashing | Indicates operational status (Green LED) and active error/fault state (Red LED) |
Replacement and Spare Part Considerations
When installing a replacement Lenze 00411352 EVF8213-E frequency inverter, maintenance teams must confirm that the power stage rating of 5.5 kW and the 320 V AC to 528 V AC input supply range match the original machine specifications. Reusing the original plug-in function modules, such as digital or analog I/O cards or fieldbus network modules, ensures full physical and functional continuity with existing control panel wiring.
A newly installed spare inverter will not operate correctly until the application-specific parameter set is transferred into its non-volatile memory. Parameter backup files saved in Lenze Global Drive Control software should be written to the replacement unit, or stored parameters can be copied directly using an E82ZTK XT Keypad module. Verifying motor control mode settings, acceleration and deceleration ramps, and fieldbus node addresses prior to enabling the drive stage prevents mechanical damage and unexpected motion during restart.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short Circuit | Short circuit on motor outputs | Short circuit in motor cable or motor winding; acceleration time too short. | Check motor cable and motor windings for short circuits; check power stage. If fault remains disconnected from motor, internal hardware failure requires repair or replacement. |
| OC2 | Earth Fault | Ground fault on motor output side | Earth fault in motor cable or motor winding; ground leakage current too high. | Check motor insulation and motor cable for earth leaks. |
| OC5 | Ixt Overload | Frequent or continuous overload condition | Drive overloaded; machine mechanically blocked; acceleration ramp too fast. | Check load mechanics, extend acceleration ramp time, check drive sizing. |
| OH | Heatsink Overtemperature | Inverter heatsink temperature exceeds limit | Ambient temperature too high; cooling fan defective or blocked; heatsink dirty; insufficient cabinet airflow. | Clean heatsink, ensure adequate cabinet ventilation, inspect internal fan operation. |
| OH4 | Motor Overtemperature | Motor temperature switch / PTC activated | Motor thermal overload; PTC sensor tripped. | Allow motor to cool down; inspect motor cooling and load conditions. |
| OU | Overvoltage | DC bus voltage exceeds upper threshold | Braking energy too high during deceleration; deceleration time set too short; mains voltage too high. | Extend deceleration time (decel ramp); install external brake resistor / brake chopper. |
| LU | Undervoltage | DC bus voltage falls below lower threshold | Mains supply voltage too low; input supply phase failure; power failure. | Check main power supply voltage and input supply fuses. |
| LP1 | Mains Phase Failure | One phase missing from 3-phase mains supply | Phase loss or severe main voltage imbalance. | Check incoming supply lines, fuses, and line contactor. |
| CEE | Communication Error | System bus or function module communication timeout / error | Faulty module connection, noise interference, loose bus connection. | Check fieldbus wiring, shield grounding, and function module seating. |
| EE | EEPROM Fault | Internal non-volatile memory checksum failure | Memory corrupted during saving or hardware fault on control board. | Reset parameters to factory defaults. If error persists, internal control board fault — replace unit. |
| H10 | Hardware Error | Internal controller hardware component fault | Failed internal power supply, ASIC fault, or power unit feedback failure. | Internal hardware fault — repair or return unit for replacement. |
| NMAX | Speed Limit Exceeded | Motor speed feedback exceeds parameter C0596 limit | Encoder feedback fault or overspeed condition. | Check speed feedback sensor wiring, scaling parameters, and load mechanics. |
Frequently Asked Questions
What software is used to configure the Lenze 00411352 EVF8213-E?
The drive is configured using Lenze Global Drive Control (GDC) software via a PC serial connection, or locally using the plug-in E82ZTK XT Keypad module.
How are parameter settings transferred to a replacement EVF8213-E inverter?
Parameters can be transferred by uploading a saved parameter file from Lenze Global Drive Control (GDC) software or by using an E82ZTK XT Keypad module to copy parameter sets directly from one drive to another.
What does the -E suffix in the model number EVF8213-E indicate?
The -E designation indicates that the drive includes an integrated Class A/B radio frequency interference (RFI) EMC filter, which suppresses electromagnetic noise without requiring external line filters in standard industrial panels.
Which communication protocols are supported by the Lenze 8200 vector series?
Through optional plug-in function modules such as the E82ZAFCC or E82ZAFPC, the drive supports CANopen, PROFIBUS-DP, INTERBUS, DeviceNet, and serial RS232/RS485 LECOM protocols.
What does fault code H10 indicate on the EVF8213-E inverter?
Fault code H10 indicates an internal hardware component error, such as a failure in the internal power supply, ASIC fault, or power stage feedback loop, requiring bench-level repair or drive replacement.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.