Lenze 13187847 E82MV751_4B001 – 8200 Motec Frequency Inverter
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze 13187847 (model E82MV751_4B001) is a 0.75 kW frequency inverter from the 8200 motec and 8200 vector drive family designed for decentralized motor control. Engineered with an IP65 protection rating, this frequency inverter mounts directly onto motor terminal boxes, machine frames, or nearby surfaces, eliminating the space requirements and cabling complexity of centralized control cabinets. Operating on a 3-phase AC input from 320 V to 528 V AC at 45 to 65 Hz, the unit provides a rated output current of 2.4 A and an output frequency range up to 480 Hz. Motor speed and torque are managed using sensorless vector control, standard linear V/f, or quadratic V/f characteristic curves, with adjustable switching frequencies between 2 kHz and 16 kHz to optimize acoustic noise and thermal efficiency.
Connecting and commissioning a replacement Lenze E82MV751_4B001 drive relies on a modular architecture that pairs the base power unit with pluggable function modules. Network integration is supported via option modules including the E82ZAFCC010 CANopen module, E82ZAFPC010 PROFIBUS-DP module, E82ZAFAC010 AS-Interface module, and E82ZAFSC010 RS-232/485 serial module. Drive commissioning and parameter cloned transfer are streamlined by swapping the removable E82ZEM memory chip from the existing drive directly into the spare unit, enabling full parameter restoration without requiring a programming PC. Before re-energizing the system, hardware address settings, fieldbus cabling, and communication card seating must be verified. ABC Industrial Parts can assist in sourcing compatible spare units and parameter memory modules to ensure minimal interruption to operations.
Diagnostics are provided on the unit via dual-color LED indicators and internal software monitors. A solid green light indicates active drive operation and readiness, while a blinking green light signifies a active controller inhibit state. A blinking red light warns of non-permissible operating conditions, whereas a solid red light indicates an active TRIP fault condition. Detailed diagnostic records are stored in the TRIP history buffer under parameter C0168 and can be extracted using the E82ZBC operating keypad or Lenze Global Drive Control (GDC) software. Common field trip events include output short circuits (OC1, OC2), earth faults (OC3), DC bus overvoltage (OU), and motor thermal overload (OH3, OH4). Internal hardware processing faults such as C09 reflect component-level faults that cannot be serviced in the field; resolving these conditions requires power cycling, complete drive replacement, or unit evaluation with ABC Industrial Parts.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | 13187847 |
| Model / Type | E82MV751_4B001 |
| Product Family | 8200 motec / 8200 vector |
| Component Type | Frequency Inverter |
| Rated Power | 0.75 kW |
| Supply Voltage Range | 320 - 528 V AC |
| Rated Output Current | 2.4 A |
| Output Voltage Range | 0 - 400 V AC |
| Output Frequency Range | 0 - 480 Hz |
| Switching Frequency | 8 kHz (Adjustable 2 - 16 kHz) |
| Control Method | Sensorless Vector Control / V/f linear / V/f quadratic |
| Protection Rating | IP65 |
| Mounting Style | Motor-Mounted or Wall-Mounted |
Programming and Configuration
The Lenze E82MV751_4B001 frequency inverter is programmed and configured using the Lenze Global Drive Control (GDC) software tool or the pluggable E82ZBC operating keypad. Through GDC, engineers can adjust motor parameters, set acceleration and deceleration ramps, configure custom V/f characteristic curves, and monitor real-time operating signals using the built-in oscilloscope function.
Parameter management and drive replacement are simplified by the removable E82ZEM memory module. Application parameter sets stored on the E82ZEM memory chip can be transferred directly to a replacement unit without establishing a software connection. If a memory checksum error occurs, represented by error code EER, reloading factory default settings or replacing the E82ZEM module restores normal parameter storage functionality.
Communication and System Integration
Network integration for the Lenze 13187847 drive is managed via modular plug-in cards fitted into the unit's function slot. Fieldbus compatibility includes CANopen via the E82ZAFCC010 module, PROFIBUS-DP via the E82ZAFPC010 module, AS-Interface via the E82ZAFAC010 module, and RS-232/485 serial communications using the E82ZAFSC010 module.
When installing or swapping communication modules, proper mounting alignment and screw torque are necessary to ensure electrical contact and maintain IP65 environmental sealing. Communication loss or interface timeout errors generate fault code CE0, requiring inspection of module seating, bus wiring, and network termination.
Diagnostics and Status Indication
Drive status is indicated on the housing via dual-color LEDs. The green LED indicates drive operational state and controller availability, while the red LED indicates active TRIP fault conditions or operating warnings.
Advanced diagnostic tools include the TRIP history memory buffer accessed via parameter C0168, which logs historic fault records. System status monitoring, error evaluation, and oscilloscope functions can also be performed via an attached E82ZBC Keypad or GDC online software connection.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Red LED | Red - Solid / Flashing | Continuous ON indicates active TRIP fault state; blinking indicates warning or impermissible operating condition. |
| Green LED | Green - Solid / Flashing | Continuous ON indicates drive operation / ready for operation; blinking indicates controller inhibit active. |
Replacement and Spare Part Considerations
When replacing an E82MV751_4B001 frequency inverter, verify that the replacement hardware matches the 0.75 kW power rating and IP65 enclosure specification to maintain environmental protection in washdown or outdoor installations.
To complete a parameter transfer without a PC, remove the E82ZEM memory module from the original drive unit and install it into the replacement inverter prior to powering on. Re-attach any installed fieldbus communication modules, ensuring that DIP switch address settings and terminal connections match the original installation.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short circuit / Overcurrent during acceleration | Output current exceeded peak limit threshold during acceleration phase. | Short circuit or earth fault on motor side; motor cable too long; acceleration time ramp too short. | Check motor wiring and insulation; increase acceleration ramp time; check motor size matching. |
| OC2 | Short circuit / Overcurrent during deceleration | Output current exceeded peak limit threshold during deceleration phase. | Deceleration ramp time too short; short circuit on motor output. | Increase deceleration ramp time; check motor and cable for short circuits. |
| OC3 | Earth fault | Ground fault detected on output phase lines. | Phase-to-ground isolation breakdown in motor winding or output cable. | Measure motor insulation resistance; check cable shield and grounding. |
| OC5 | I x t Overload | Thermal drive overload limit reached due to continuous high current output. | Mechanical overload on driven load; motor undersized for application. | Check drive loading and mechanical system for binding or excessive torque requirement. |
| OU | Overvoltage DC bus | DC bus voltage exceeded safe maximum limit. | Regenerative energy from motor during deceleration; supply voltage transient spike. | Extend deceleration time; install brake chopper / braking resistor if required. |
| LU | Undervoltage DC bus | DC bus voltage fell below minimum operation threshold. | Mains supply drop or phase loss; supply voltage under minimum requirement. | Check incoming AC power supply voltage and fuses. |
| OH | Overtemperature Heatsink | Heatsink temperature exceeded upper limit. | Inadequate cooling / airflow obstruction; ambient cooling surface dirty or covered. | Clean heatsink cooling fins; verify adequate clearance around unit. |
| OH3 | Motor Over-temperature (PTC) | Motor thermistor/PTC sensor triggered high temperature fault. | Motor thermal overload; motor fan clogged or defective. | Allow motor to cool down; check motor ventilation and load requirements. |
| OH4 | Motor I2t Overload | Calculated motor I2t thermal model exceeded limit. | Continuous high motor current operation at low speed. | Check motor current setting; verify forced ventilation if operating at low speeds. |
| C09 | System fault | Internal micro-controller or hardware control processing fault. | Internal electronic board-level fault; severe electro-magnetic interference. | Internal hardware fault — power cycle drive unit; if fault persists, unit requires repair or replacement. |
| CE0 | Communication error to function module | Time-out or error on communication interface between basic inverter unit and attached function/fieldbus module. | Function module loose or unseated; fieldbus communication loss. | Check module seating and mounting screws; inspect fieldbus cabling. |
| EER | EEPROM memory error | Read/write checksum failure when accessing non-volatile EEPROM memory. | Defective memory chip or corrupted parameter storage. | Reload factory default parameter set; replace E82ZEM memory module if persistent. |
| LP1 | Motor phase failure | Interruption detected in one of the output motor phases. | Motor cable broken or disconnected; motor winding open circuit. | Check output cable connections and motor terminal box connections. |
| P12 | Process variable loss | Feedback signal error in PID process controller mode. | Feedback sensor broken or wire disconnected. | Inspect analog feedback sensor and wiring. |
Frequently Asked Questions
How do I transfer parameters to a replacement Lenze E82MV751_4B001 drive?
Parameters can be transferred without a computer by swapping the pluggable E82ZEM memory chip from the existing drive into the replacement unit before powering up.
What power supply voltage is required for the Lenze 13187847 inverter?
The inverter operates on a 3-phase AC input supply ranging from 320 V AC to 528 V AC at 45 to 65 Hz, supplying an output current of 2.4 A.
What do the status LEDs on the front panel indicate?
A solid green LED indicates normal operation, while a flashing green LED indicates controller inhibit. A flashing red LED signals a warning condition, and a solid red LED indicates an active TRIP fault.
Which fieldbus modules are compatible with this drive?
The E82MV751_4B001 supports optional plug-in modules including CANopen (E82ZAFCC010), PROFIBUS-DP (E82ZAFPC010), AS-Interface (E82ZAFAC010), and RS-232/485 (E82ZAFSC010).
What action should be taken if error code C09 appears?
Fault code C09 indicates an internal microcontroller or hardware processing fault. Power cycle the drive; if the fault persists, internal hardware evaluation or drive replacement is required.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.