Lenze 13189772 E82MV152_4B001 8200 Motec 1.5kW Inverter

New 
On request
Refurbished   
2 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 motec | Series: 8200 motec

The Lenze 13189772, model E82MV152_4B001, is a 1.5 kW decentralized frequency inverter belonging to the Lenze 8200 motec series. Built with a heavy-duty IP65-rated enclosure, this speed controller is designed for direct motor terminal box or machine wall mounting without requiring a protective control cabinet. The drive operates on a 3-phase AC mains supply from 320 V AC to 550 V AC at 45 Hz to 65 Hz, delivering a rated output current of 3.9 A with an adjustable switching frequency up to 16 kHz (8 kHz nominal) and an output frequency range from 0 to 480 Hz. Motor control is maintained through either V/f characteristic control or sensorless vector control, making it suitable for field placement in conveyor drives, pump and fan automation, and overhead crane positioning systems.

Commissioning a replacement drive requires careful alignment of communication modules and configuration data. The drive features a modular structure where the power unit is separated from pluggable function module slots, accommodating interface cards such as CANopen (E82ZAFPC), PROFIBUS DP (E82ZAFDP), INTERBUS (E82ZAFIB), or AS-Interface (E82ZAFAS). Standard spares are rarely plug-and-run; parameter sets must be transferred from the original unit or loaded from backup files into the non-volatile EEPROM memory. Parameters can be modified and uploaded using Lenze Global Drive Control (GDC) software or the pluggable XT Keypad E82ZBC. Technical support from ABC Industrial Parts can assist maintenance teams with parameter extraction and transfer from original units during drive replacement.

System health and operational states are reported via dual LED status indicators, with dedicated fault codes visible through the XT Keypad E82ZBC or GDC diagnostic interface. When troubleshooting operational trips, technicians should verify input supply levels, check output wiring on terminals U, V, and W, inspect motor PTC connections on terminals T1 and T2, and confirm fieldbus termination resistors (120 Ohm). Critical fault codes such as H05 or EEr indicate internal control circuit or memory corruption, which are non-field-serviceable defects. In these cases, sourcing a tested exchange unit or utilizing professional repair through ABC Industrial Parts ensures rapid restoration of operational throughput.

Technical Specifications

ManufacturerLenze
Part Number13189772
Model / TypeE82MV152_4B001
Product Family8200 motec
Component TypeFrequency Inverter
Rated Power1.5 kW
Supply Voltage Range320 - 550 V AC (3-phase)
Nominal Supply Voltage400 V AC
Rated Input Current3.8 A
Rated Output Current3.9 A
Output Voltage Range0 - 400 V AC
Output Frequency Range0 - 480 Hz
Nominal Switching Frequency8 kHz (up to 16 kHz)
Control MethodsV/f characteristic control, sensorless vector control
Protection RatingIP65
Mounting TypeDecentralized motor-mounted / wall-mounted

Programming and Configuration

Parameterization of the Lenze 13189772 frequency inverter is conducted using Lenze Global Drive Control (GDC) software or via the pluggable XT Keypad E82ZBC. The drive internal memory contains non-volatile EEPROM storage capable of holding dual parameter sets. This allows operators to maintain primary and secondary application profiles directly within the unit without data loss during main power outages.

When commissioning or reconfiguring the unit, parameters can be transferred directly between drives using the XT Keypad or loaded via software link. Parameter C0002 provides a dedicated reset path to restore factory default settings, while parameter C0168 serves as a diagnostic buffer holding active and past fault codes. Ensuring exact matching of parameter values between old and new drives is essential for maintaining correct motor acceleration ramps, thermal protection limits, and fieldbus node parameters.

Communication and System Integration

The Lenze 8200 motec architecture utilizes a modular interface concept separating power electronics from network communication. The inverter includes a dedicated slot for fieldbus function modules, allowing seamless connection to decentralized industrial fieldbuses. Supported module options include PROFIBUS DP (E82ZAFDP), CANopen system bus (E82ZAFPC), INTERBUS (E82ZAFIB), and AS-Interface (E82ZAFAS).

When integrating the drive into a fieldbus network, node addresses and communication speeds must be properly matched to the host network controller. For CANopen networks, physical installation requires installing 120 Ohm termination resistors at both bus end points. Secure mechanical locking of the plugged function module onto the inverter chassis is required to maintain the overall IP65 ingress rating and prevent communication dropouts caused by field vibration.

Diagnostics and Status Indication

Real-time diagnostic feedback on the Lenze 13189772 is provided through integrated status LEDs located on the housing alongside numerical codes displayed via connected keypads or software. The drive features dual LED indicators representing active mains operation and fault conditions. Detailed diagnostic records, including historical fault codes, can be retrieved directly from the C0168 fault buffer.

Status LED Indicators

LEDColor/StatusMeaning
Red LEDRed - Solid / FlashingFault / TRIP indicator
Green LEDGreen - Solid / FlashingOperation / Power status indicator

Replacement and Spare Part Considerations

When replacing an existing Lenze 13189772 E82MV152_4B001 drive, physical mounting, power ratings, and installed communication hardware must match the original machine specifications. Because the drive is built with an IP65 protection rating for decentralized field placement, ensure that seals and cable glands are intact during installation to maintain environmental protection.

Function modules must be moved from the existing drive to the replacement unit or configured identically if installing new modules. Transfer the parameter set stored in the EEPROM using either the XT Keypad E82ZBC or Lenze Global Drive Control software to match application-specific motor parameters, acceleration ramps, and fieldbus address settings.

In cases where internal hardware failure codes like H05 or persistent memory corruption codes like EEr occur, field repairs on circuit boards are not feasible. Replacing the entire inverter module or sending the unit for factory-level board repair is required to bring the equipment back into service.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short Circuit / Earth Fault / OvercurrentInstantaneous overcurrent during acceleration or power stage output short circuit / earth faultShort circuit in motor cable, earth fault in motor winding, motor power rating too large for inverter, acceleration ramp too shortCheck motor and motor cable for short circuit or insulation fault; extend acceleration time; verify motor match
OC2Overcurrent DecelerationOvercurrent during deceleration phaseDeceleration time too short, regenerative energy too high without braking resistorIncrease deceleration ramp time or check braking module configuration
OC5Drive Overload (I x t)Continuous overload threshold reachedMechanical overload on motor, drive undersized for dynamic duty cycleReduce mechanical load; check motor sizing and drive continuous current rating
OUOvervoltage DC BusIntermediate circuit DC bus voltage exceeded upper limitMains supply voltage too high, regenerative energy during deceleration without chopperCheck mains voltage; extend deceleration time; install external braking resistor/module if applicable
LUUndervoltage DC BusIntermediate circuit DC bus voltage dropped below minimum operating limitMains voltage too low, mains phase failure, power supply interruptionCheck mains voltage supply and input fuses
OHHeatsink OvertemperatureDrive heatsink temperature exceeds maximum allowed limitAmbient temperature too high, cooling fins clogged, insufficient ventilation, fan failureClean heatsink cooling fins, improve ambient ventilation, replace unit if internal thermal sensor damaged
OH3Motor OvertemperatureMotor temperature sensor triggered thermal shutdownMotor thermal overload, PTC sensor wire disconnected or faultyCheck motor load and cooling; verify PTC sensor connection at terminal T1/T2
OH4Internal Drive OvertemperatureInternal enclosure or control board temperature exceeds thresholdAmbient temperature too high, internal ventilation blockedCheck ambient temperature and mounting space around inverter
CE0Communication Error Function ModuleInterruption of data transmission between frequency inverter and plugged function moduleFunction module loose, loose connection or hardware fault on control moduleCheck function module seats properly; power cycle drive; replace function module if issue persists
CE1CANbus Communication ErrorSystem bus (CAN) communication monitoring faultBus cable broken, improper termination, baud rate mismatch, CAN master failureCheck CANbus wiring, termination resistors (120 Ohm), and node ID/baud rate settings
EErEEPROM Data FaultInternal EEPROM memory failure or corruption during reading/writingInternal memory corruption, power interrupt during parameter save, hardware defectInternal hardware fault — reset parameters to factory default; if error persists, return unit for repair or replace drive
H05Internal Hardware FaultInternal control circuit or power board diagnostic defect detectedBoard-level failure in gate drive or micro-controller circuitInternal board-level failure — non-field-serviceable; return unit for repair or replace frequency inverter
P12Parameter Set Checksum ErrorInconsistent parameter set detected in memoryParameter transfer interrupted or invalid parameter loadedReload valid parameter set or restore factory default settings (C0002)
LP1Motor Phase LossLoss of one output phase to the motorLoose connection in output terminals, motor winding open circuitCheck wiring between drive output terminals U, V, W and motor terminals

Frequently Asked Questions

What engineering software is used to configure the Lenze 13189772 inverter?

The inverter is configured using Lenze Global Drive Control (GDC) software or manually using the pluggable XT Keypad E82ZBC.

What mounting styles are supported by the E82MV152_4B001 drive?

The unit features an IP65 enclosure designed for decentralized installation directly on motor terminal boxes or adjacent machine walls without a control cabinet.

How are parameter backups transferred to a spare drive?

Parameters stored in the non-volatile EEPROM memory can be copied using the XT Keypad E82ZBC module or uploaded/downloaded using GDC software.

Which communication fieldbuses are compatible with this drive?

The drive supports pluggable function modules for PROFIBUS DP (E82ZAFDP), CANopen (E82ZAFPC), INTERBUS (E82ZAFIB), and AS-Interface (E82ZAFAS).

What does a fault code H05 indicate on the drive?

Fault code H05 indicates an internal hardware failure on the control or power board. This fault is non-field-serviceable and requires drive repair or replacement.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.