Lenze 13267644 EVS9329-EP 45kW 9300 Servo Drive
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze 13267644 EVS9329-EP is a 45 kW servo drive belonging to the Lenze 9300 Servo series, engineered for high-power dynamic positioning and speed regulation in industrial motion applications. Operating on a three-phase supply voltage ranging from 320 V AC to 528 V AC at 45 Hz to 65 Hz, the drive delivers a rated continuous output current of 89 A with a peak output capability of 133.5 A and a maximum output frequency of 480 Hz. Featuring built-in Extended Positioning (EP) control, this servo inverter allows positioning programs, point-to-point sequences, and homing routines to run directly on the drive without requiring a separate PLC positioning controller.
System connectivity is provided through an integrated CANopen system bus interface, 6 digital inputs, 4 digital outputs, 2 analog inputs, and 2 analog outputs, along with dedicated terminal connections for resolver (X7) and encoder feedback (X8). An optional Automation Interface (AIF) slot accepts fieldbus modules such as EMF2133IB PROFIBUS or EMF2191IB Ethernet cards. Commissioning a replacement unit involves transferring the machine-specific parameter set (PAR1 through PAR4) and positioning profile data onto the replacement drive using Lenze Global Drive Control (GDC) software V4.x+ or an EMZ9371BC Keypad XT module. When replacing a failed unit, matching parameter configurations and firmware requirements is essential to restore proper operational state, and ABC Industrial Parts can assist with tested replacement drives and configuration transfers.
The drive features three front status LEDs indicating operational readiness (solid green Power/Ready), active TRIP fault conditions (solid or blinking red Fault), and current limiting or warning thresholds (solid yellow Warning). Diagnostic codes can be retrieved on the Keypad XT via parameter C0003 or monitored in real time using GDC software. Fault conditions such as OC1 (short circuit), OU (DC bus overvoltage), LU (DC bus undervoltage), CE0/CE1 (communication errors), and EE0 (EEPROM memory error) highlight clear diagnostic paths, whereas internal logic failures such as H05 signal board-level errors that are not field-serviceable. For hardware failures requiring immediate action, ABC Industrial Parts provides tested exchange units and repair options to bring production machinery back online quickly.
Technical Specifications
| Rated Power | 45 kW |
| Supply Voltage Range | 320 - 528 V AC |
| Supply Frequency | 45 - 65 Hz |
| Rated Output Current | 89 A |
| Maximum Output Current | 133.5 A |
| Maximum Output Frequency | 480 Hz |
| Switching Frequency | 8 kHz |
| Digital Inputs | 6 |
| Digital Outputs | 4 |
| Analog Inputs | 2 |
| Analog Outputs | 2 |
| Integrated Fieldbus Interface | CANopen / Lenze System Bus |
Programming and Configuration
The EVS9329-EP features integrated Extended Positioning (EP) firmware that allows motion block commands, positioning targets, homing reference routines, and sequence profiles to be configured directly within the drive. Motion parameters and parameter sets (PAR1 through PAR4) are managed using Lenze Global Drive Control (GDC) PC software version 4.x or higher, connected via fieldbus or direct communication interfaces.
Commissioning or replacing a drive requires loading stored parameter files into the replacement unit to ensure matching acceleration profiles, velocity loop gain settings, and positioning block tables. Alternatively, parameter replication can be completed using the plug-in EMZ9371BC Keypad XT module, which allows direct parameter set cloning without requiring a PC connection on the factory floor.
Communication and System Integration
Inter-drive communication and control system integration are supported via the built-in CANopen / Lenze System Bus interface accessible at connector X4. Operating with configurable baud rates and standard 120-ohm termination resistors, this bus enables high-speed synchronization across multiple drive axes and real-time parameter exchange.
Expansion for high-level fieldbus architectures is accomplished through the integrated Automation Interface (AIF) slot. The drive accepts optional AIF communication cards, including EMF2133IB PROFIBUS-DP, EMF2191IB Ethernet, and Interbus modules, integrating the drive into diverse PLC-driven automation networks.
Diagnostics and Status Indication
Diagnostic evaluation on the EVS9329-EP is facilitated by three status LEDs located on the front panel, providing immediate status feedback for power, active TRIP conditions, and thermal or current warnings. Detailed fault diagnostics and trip history memory are accessible via Keypad XT code C0003, or through real-time oscilloscope and monitoring tools within Lenze Global Drive Control (GDC) software.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Ready / Power | Green - Solid | Ready for operation / Power ON |
| Fault | Red - Solid / Blinking | Fault active (TRIP condition) |
| Warning | Yellow - Solid | Warning active / current limit reached |
Replacement and Spare Part Considerations
When replacing an existing Lenze 13267644 EVS9329-EP drive, ensure that the incoming three-phase supply (320–528 V AC) and motor feedback connections at terminals X7 (resolver) or X8 (encoder) match the original wiring configuration. Check that optional plug-in modules, such as AIF fieldbus cards (EMF2133IB or EMF2191IB), are correctly transferred to the replacement drive's expansion slot.
A replacement drive will not operate in the machine until parameter sets PAR1 through PAR4 and positioning profile sequences are copied from the original unit or backup repository. Verify that parameter memory (EEPROM) is correctly written and perform a homing routine to confirm target positioning boundaries before resuming automatic operation.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short Circuit | Short circuit or extreme overcurrent detected at motor output terminals | Short circuit in motor cable, winding ground fault, motor cable too long, or power transistor stage fault | Check motor wiring and insulation; check motor windings for short circuit; if error persists without motor connected, internal power stage failure requires return for repair. |
| OC2 | Earth Fault | Ground fault / earth leakage current detected on output phase | Ground fault in motor lead or motor winding insulation breakdown | Check motor and motor cables for insulation breakdown to ground. |
| OC5 | Overload Acceleration | Overcurrent condition during acceleration phase | Acceleration time ramp too short, mechanical blockage, or excessive motor load | Increase acceleration ramp time; verify load mechanics move freely; check motor sizing. |
| OU | Overvoltage DC Bus | DC bus voltage exceeds upper threshold limit (> 770 V DC / 800 V DC) | Regenerative energy during deceleration too high, braking resistor missing/defective, or deceleration ramp too fast | Increase deceleration ramp time; verify braking chopper operation and external braking resistor value/connection. |
| LU | Undervoltage DC Bus | DC bus voltage fell below lower threshold limit (< 400 V DC) | Mains supply failure, supply line voltage drop, or missing input phase | Check 3-phase mains supply voltage and fuses; check DC link connections. |
| OH | Heatsink Overtemperature | Drive heatsink temperature exceeded maximum safety threshold (> 85°C / 90°C) | Inadequate control cabinet cooling, clogged heatsink/fan, ambient temperature too high, or continuous drive overload | Clean heatsink cooling fins; verify operation of internal enclosure fan; lower ambient temperature or reduce continuous switching frequency/load. |
| OH3 | Motor Overtemperature PTC | Motor temperature sensor trip via T1/T2 terminals | Motor thermal overload, clogged motor cooling fans, or open circuit on PTC sensor terminals | Allow motor to cool down; check thermal sensor wiring (PTC/TK) at terminals T1/T2; verify motor fan functionality. |
| OH4 | Drive Thermal Load Continuous | Calculated thermal load of power stage exceeds allowed continuous limit | Extended operation in high overload zone (I > rated I_N) | Reduce duty cycle or continuous output load. |
| OH7 | Motor Temperature Model | Calculated motor overload via internal I2t motor protection algorithm | Excessive continuous low-speed operation with high load current | Check motor dimensioning; allow cooling; check motor thermal time constant settings. |
| LP1 | Mains Phase Failure | One of the incoming AC supply phases is missing | Blown supply fuse, loose line connection, or phase imbalance | Measure input voltage on terminals L1, L2, L3; check supply fuses and contactors. |
| CE0 | AIF Communication Error | Communication interruption between drive control board and optional plug-in AIF fieldbus card | Loose module seat, defective bus card, or fieldbus master timeout | Verify proper mechanical seating of AIF card; check fieldbus cable, bus termination, and PLC status. |
| CE1 | System Bus CAN Error | System bus (CAN) communication error or bus-off state | Interrupted CAN line, incorrect baud rate, missing 120 ohm termination resistors, or noisy electrical ground | Check CAN wiring at X4, verify baud rate matching across all nodes, and check termination resistors. |
| EE0 | EEPROM Memory Error | Data corruption detected during EEPROM access or checksum mismatch | Interrupted parameter write process or non-volatile EEPROM failure | Reload factory default settings (C0002 = 1); re-download parameter file; if error persists, internal control board fault requires repair/replacement. |
| Sd1 | Resolver Fault | Resolver signal open circuit or track fault detected on X7 | Defective resolver cable, loose Sub-D connector, or damaged resolver sensor | Inspect cable and shielding connected to X7; replace resolver cable or motor feedback sensor. |
| Sd2 | Encoder Signal Error | Incremental / SinCos encoder track error or loss of signal on X8 | Encoder cable fault, missing supply voltage, or damaged encoder | Check connector X8, check encoder supply voltage, verify encoder cable shield ground. |
| NMAX | Overspeed | Motor actual speed exceeded max speed safety setting (C0596) | Feedback polarity reversed, gain tuning instability, or external pulling load | Check feedback encoder/resolver phase sequence and mechanical coupling; adjust velocity loop gain settings. |
| H05 | Internal Hardware Error | Internal control board logic fault or micro-controller hardware failure | Board hardware damage or component failure | Internal hardware fault — return unit for repair or replace complete drive controller. |
| PR0 | Program Sequence Error | Invalid motion block command or sequence error in Extended Positioning profile | Positioning program error, out-of-range position target, or improper homing status | Check target position limits, homing reference execution, and positioning profile sequence program in GDC. |
Frequently Asked Questions
What software is required to configure the Lenze 13267644 EVS9329-EP servo drive?
The drive is configured using Lenze Global Drive Control (GDC) PC software version 4.x or higher, or directly on the unit using an EMZ9371BC Keypad XT module.
Can the EVS9329-EP execute positioning routines without an external PLC positioning card?
Yes, the integrated Extended Positioning (EP) firmware manages point-to-point positioning profiles, homing reference sequences, and motion block commands directly on the drive.
How do I transfer parameters from a failed drive to a replacement unit?
Parameters can be backed up and reloaded using Lenze GDC software or cloned directly between drive units using the EMZ9371BC Keypad XT module.
Which fieldbus networks can be connected to the EVS9329-EP?
The drive includes an integrated CANopen system bus and an AIF expansion slot that supports optional cards for PROFIBUS-DP (EMF2133IB), Ethernet (EMF2191IB), and Interbus.
What action should be taken if fault code H05 appears?
Fault code H05 indicates an internal control board logic or micro-controller hardware failure, which cannot be serviced in the field and requires drive repair or replacement.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.