Lenze 13267644 EVS9329-EP 45kW 9300 Servo Drive

New 
1 available for direct collection
Refurbished   
On request
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo | Series: 9300

The Lenze 13267644 EVS9329-EP is a 45 kW servo drive belonging to the Lenze 9300 Servo series, engineered for high-power dynamic positioning and speed regulation in industrial motion applications. Operating on a three-phase supply voltage ranging from 320 V AC to 528 V AC at 45 Hz to 65 Hz, the drive delivers a rated continuous output current of 89 A with a peak output capability of 133.5 A and a maximum output frequency of 480 Hz. Featuring built-in Extended Positioning (EP) control, this servo inverter allows positioning programs, point-to-point sequences, and homing routines to run directly on the drive without requiring a separate PLC positioning controller.

System connectivity is provided through an integrated CANopen system bus interface, 6 digital inputs, 4 digital outputs, 2 analog inputs, and 2 analog outputs, along with dedicated terminal connections for resolver (X7) and encoder feedback (X8). An optional Automation Interface (AIF) slot accepts fieldbus modules such as EMF2133IB PROFIBUS or EMF2191IB Ethernet cards. Commissioning a replacement unit involves transferring the machine-specific parameter set (PAR1 through PAR4) and positioning profile data onto the replacement drive using Lenze Global Drive Control (GDC) software V4.x+ or an EMZ9371BC Keypad XT module. When replacing a failed unit, matching parameter configurations and firmware requirements is essential to restore proper operational state, and ABC Industrial Parts can assist with tested replacement drives and configuration transfers.

The drive features three front status LEDs indicating operational readiness (solid green Power/Ready), active TRIP fault conditions (solid or blinking red Fault), and current limiting or warning thresholds (solid yellow Warning). Diagnostic codes can be retrieved on the Keypad XT via parameter C0003 or monitored in real time using GDC software. Fault conditions such as OC1 (short circuit), OU (DC bus overvoltage), LU (DC bus undervoltage), CE0/CE1 (communication errors), and EE0 (EEPROM memory error) highlight clear diagnostic paths, whereas internal logic failures such as H05 signal board-level errors that are not field-serviceable. For hardware failures requiring immediate action, ABC Industrial Parts provides tested exchange units and repair options to bring production machinery back online quickly.

Technical Specifications

Rated Power45 kW
Supply Voltage Range320 - 528 V AC
Supply Frequency45 - 65 Hz
Rated Output Current89 A
Maximum Output Current133.5 A
Maximum Output Frequency480 Hz
Switching Frequency8 kHz
Digital Inputs6
Digital Outputs4
Analog Inputs2
Analog Outputs2
Integrated Fieldbus InterfaceCANopen / Lenze System Bus

Programming and Configuration

The EVS9329-EP features integrated Extended Positioning (EP) firmware that allows motion block commands, positioning targets, homing reference routines, and sequence profiles to be configured directly within the drive. Motion parameters and parameter sets (PAR1 through PAR4) are managed using Lenze Global Drive Control (GDC) PC software version 4.x or higher, connected via fieldbus or direct communication interfaces.

Commissioning or replacing a drive requires loading stored parameter files into the replacement unit to ensure matching acceleration profiles, velocity loop gain settings, and positioning block tables. Alternatively, parameter replication can be completed using the plug-in EMZ9371BC Keypad XT module, which allows direct parameter set cloning without requiring a PC connection on the factory floor.

Communication and System Integration

Inter-drive communication and control system integration are supported via the built-in CANopen / Lenze System Bus interface accessible at connector X4. Operating with configurable baud rates and standard 120-ohm termination resistors, this bus enables high-speed synchronization across multiple drive axes and real-time parameter exchange.

Expansion for high-level fieldbus architectures is accomplished through the integrated Automation Interface (AIF) slot. The drive accepts optional AIF communication cards, including EMF2133IB PROFIBUS-DP, EMF2191IB Ethernet, and Interbus modules, integrating the drive into diverse PLC-driven automation networks.

Diagnostics and Status Indication

Diagnostic evaluation on the EVS9329-EP is facilitated by three status LEDs located on the front panel, providing immediate status feedback for power, active TRIP conditions, and thermal or current warnings. Detailed fault diagnostics and trip history memory are accessible via Keypad XT code C0003, or through real-time oscilloscope and monitoring tools within Lenze Global Drive Control (GDC) software.

Status LED Indicators

LEDColor/StatusMeaning
Ready / PowerGreen - SolidReady for operation / Power ON
FaultRed - Solid / BlinkingFault active (TRIP condition)
WarningYellow - SolidWarning active / current limit reached

Replacement and Spare Part Considerations

When replacing an existing Lenze 13267644 EVS9329-EP drive, ensure that the incoming three-phase supply (320–528 V AC) and motor feedback connections at terminals X7 (resolver) or X8 (encoder) match the original wiring configuration. Check that optional plug-in modules, such as AIF fieldbus cards (EMF2133IB or EMF2191IB), are correctly transferred to the replacement drive's expansion slot.

A replacement drive will not operate in the machine until parameter sets PAR1 through PAR4 and positioning profile sequences are copied from the original unit or backup repository. Verify that parameter memory (EEPROM) is correctly written and perform a homing routine to confirm target positioning boundaries before resuming automatic operation.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short CircuitShort circuit or extreme overcurrent detected at motor output terminalsShort circuit in motor cable, winding ground fault, motor cable too long, or power transistor stage faultCheck motor wiring and insulation; check motor windings for short circuit; if error persists without motor connected, internal power stage failure requires return for repair.
OC2Earth FaultGround fault / earth leakage current detected on output phaseGround fault in motor lead or motor winding insulation breakdownCheck motor and motor cables for insulation breakdown to ground.
OC5Overload AccelerationOvercurrent condition during acceleration phaseAcceleration time ramp too short, mechanical blockage, or excessive motor loadIncrease acceleration ramp time; verify load mechanics move freely; check motor sizing.
OUOvervoltage DC BusDC bus voltage exceeds upper threshold limit (> 770 V DC / 800 V DC)Regenerative energy during deceleration too high, braking resistor missing/defective, or deceleration ramp too fastIncrease deceleration ramp time; verify braking chopper operation and external braking resistor value/connection.
LUUndervoltage DC BusDC bus voltage fell below lower threshold limit (< 400 V DC)Mains supply failure, supply line voltage drop, or missing input phaseCheck 3-phase mains supply voltage and fuses; check DC link connections.
OHHeatsink OvertemperatureDrive heatsink temperature exceeded maximum safety threshold (> 85°C / 90°C)Inadequate control cabinet cooling, clogged heatsink/fan, ambient temperature too high, or continuous drive overloadClean heatsink cooling fins; verify operation of internal enclosure fan; lower ambient temperature or reduce continuous switching frequency/load.
OH3Motor Overtemperature PTCMotor temperature sensor trip via T1/T2 terminalsMotor thermal overload, clogged motor cooling fans, or open circuit on PTC sensor terminalsAllow motor to cool down; check thermal sensor wiring (PTC/TK) at terminals T1/T2; verify motor fan functionality.
OH4Drive Thermal Load ContinuousCalculated thermal load of power stage exceeds allowed continuous limitExtended operation in high overload zone (I > rated I_N)Reduce duty cycle or continuous output load.
OH7Motor Temperature ModelCalculated motor overload via internal I2t motor protection algorithmExcessive continuous low-speed operation with high load currentCheck motor dimensioning; allow cooling; check motor thermal time constant settings.
LP1Mains Phase FailureOne of the incoming AC supply phases is missingBlown supply fuse, loose line connection, or phase imbalanceMeasure input voltage on terminals L1, L2, L3; check supply fuses and contactors.
CE0AIF Communication ErrorCommunication interruption between drive control board and optional plug-in AIF fieldbus cardLoose module seat, defective bus card, or fieldbus master timeoutVerify proper mechanical seating of AIF card; check fieldbus cable, bus termination, and PLC status.
CE1System Bus CAN ErrorSystem bus (CAN) communication error or bus-off stateInterrupted CAN line, incorrect baud rate, missing 120 ohm termination resistors, or noisy electrical groundCheck CAN wiring at X4, verify baud rate matching across all nodes, and check termination resistors.
EE0EEPROM Memory ErrorData corruption detected during EEPROM access or checksum mismatchInterrupted parameter write process or non-volatile EEPROM failureReload factory default settings (C0002 = 1); re-download parameter file; if error persists, internal control board fault requires repair/replacement.
Sd1Resolver FaultResolver signal open circuit or track fault detected on X7Defective resolver cable, loose Sub-D connector, or damaged resolver sensorInspect cable and shielding connected to X7; replace resolver cable or motor feedback sensor.
Sd2Encoder Signal ErrorIncremental / SinCos encoder track error or loss of signal on X8Encoder cable fault, missing supply voltage, or damaged encoderCheck connector X8, check encoder supply voltage, verify encoder cable shield ground.
NMAXOverspeedMotor actual speed exceeded max speed safety setting (C0596)Feedback polarity reversed, gain tuning instability, or external pulling loadCheck feedback encoder/resolver phase sequence and mechanical coupling; adjust velocity loop gain settings.
H05Internal Hardware ErrorInternal control board logic fault or micro-controller hardware failureBoard hardware damage or component failureInternal hardware fault — return unit for repair or replace complete drive controller.
PR0Program Sequence ErrorInvalid motion block command or sequence error in Extended Positioning profilePositioning program error, out-of-range position target, or improper homing statusCheck target position limits, homing reference execution, and positioning profile sequence program in GDC.

Frequently Asked Questions

What software is required to configure the Lenze 13267644 EVS9329-EP servo drive?

The drive is configured using Lenze Global Drive Control (GDC) PC software version 4.x or higher, or directly on the unit using an EMZ9371BC Keypad XT module.

Can the EVS9329-EP execute positioning routines without an external PLC positioning card?

Yes, the integrated Extended Positioning (EP) firmware manages point-to-point positioning profiles, homing reference sequences, and motion block commands directly on the drive.

How do I transfer parameters from a failed drive to a replacement unit?

Parameters can be backed up and reloaded using Lenze GDC software or cloned directly between drive units using the EMZ9371BC Keypad XT module.

Which fieldbus networks can be connected to the EVS9329-EP?

The drive includes an integrated CANopen system bus and an AIF expansion slot that supports optional cards for PROFIBUS-DP (EMF2133IB), Ethernet (EMF2191IB), and Interbus.

What action should be taken if fault code H05 appears?

Fault code H05 indicates an internal control board logic or micro-controller hardware failure, which cannot be serviced in the field and requires drive repair or replacement.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.