Lenze 13318988 E84AVBDE5512SX0 0.55 kW Frequency Inverter
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze 13318988, model designation E84AVBDE5512SX0, is a 0.55 kW panel-mount frequency inverter within the 8400 StateLine C family designed for precise motor control in automated machinery. Built with an IP20 protection rating for control cabinet mounting, this variable frequency drive operates on single-phase or three-phase 230 V to 240 V AC supply networks across an allowable voltage range of 180 V to 264 V AC. The inverter delivers a nominal output current of 3 A at an 8 kHz switching frequency and provides a dynamic 150% overload rating of 4.5 A for up to 60 seconds. Flexible motor control is achieved using V/f characteristic control with linear or square-law curves or sensorless vector control (SLVC) over an output frequency range of 0 to 599 Hz.
Field integration and replacement procedures are streamlined through plug-in control terminal strips and an integrated CANopen system bus. For setups requiring broader fieldbus connectivity, open slot architecture supports extension modules for PROFINET, PROFIBUS-DP, EtherCAT, and EtherNet/IP. Putting a replacement drive into operation does not require onsite software configuration when using the hot-swappable E84AYM256K memory module, which transfers complete parameter sets between devices without special tools. Parameter adjustments and project setups can also be conducted using Lenze EASY Starter or L-force Engineer engineering tools, alongside the optional Keypad XT operator module, with technical assistance available from ABC Industrial Parts for parameter extraction and drive commissioning.
Real-time diagnostic status is displayed through four dedicated LEDs on the front panel: DRV-READY, DRV-ERR, CAN-RUN, and CAN-ERR. Internal fault conditions, including overcurrent, DC-bus overvoltage, undervoltage, and thermal warnings, are logged in device registers C00168 and C00170. First-line troubleshooting should verify input power stability, motor cable integrity, shield connections, line termination resistors, and extension module seating. When internal hardware errors such as code H05 occur, field repairs are not feasible, and unit replacement or repair through ABC Industrial Parts provides the fastest path to restoring operational productivity.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | 13318988 |
| Model / Type | E84AVBDE5512SX0 |
| Product Family | 8400 StateLine C |
| Component Type | Frequency Inverter |
| Rated Power | 0.55 kW |
| Supply Voltage | 230 / 240 V AC |
| Supply Voltage Range | 180 - 264 V AC |
| Input Phase Configuration | 1-Phase / 3-Phase |
| Rated Output Current | 3 A |
| Maximum Output Current (60s) | 4.5 A |
| Output Frequency Range | 0 - 599 Hz |
| Switching Frequency | 8 kHz |
| Control Method | V/f characteristic control, Sensorless Vector Control (SLVC) |
| Digital Inputs | 5 |
| Digital Outputs | 1 HTL (50 mA) + 1 Relay (changeover) |
| Analog Inputs | 2 |
| Analog Outputs | 1 |
| Protection Rating | IP20 |
| Mounting Type | Panel Mount |
Programming and Configuration
Drive setup and parameterization for the Lenze 13318988 inverter can be performed using Lenze EASY Starter or L-force Engineer software. These PC-based engineering tools allow technicians to adjust motor parameters, manage dynamic ramp times, configure V/f curves, and monitor real-time operating variables via oscilloscope views and diagnostic screens.
Parameter management is highly accessible through the removable Lenze E84AYM256K Memory Module. Entire parameter datasets are retained directly on this plug-in module, allowing configurations to be replicated across identical drives or restored to replacement units without requiring software installations or cable connections.
For manual parameterization and on-site operation, the drive supports the optional Lenze Keypad XT (E84EZKAX000). The keypad attaches directly to the front interface slot, enabling local parameter modification, manual speed overrides, and direct access to diagnostic fault logs during routine maintenance.
Communication and System Integration
The E84AVBDE5512SX0 inverter features a built-in CANopen system bus interface. This embedded fieldbus connection provides deterministic communication for multi-axis coordination, remote parameter access, and system-wide diagnostic monitoring across industrial automation networks.
To accommodate centralized PLC architectures, the drive includes an extension slot that accepts optional fieldbus modules. Supported fieldbus options include PROFINET, PROFIBUS-DP, EtherCAT, and EtherNet/IP, allowing seamless integration into higher-level control systems without changing the core inverter hardware.
Control wiring connects via detachable terminal strips designed for simple maintenance. The I/O topology provides 5 digital inputs, 1 HTL digital output (50 mA), 1 changeover relay output, 2 analog inputs, and 1 analog output, giving plant engineers full flexibility for local control switches, speed reference signals, and status feedback.
Diagnostics and Status Indication
Direct visual status monitoring is provided by four LED indicators located on the front of the drive. These indicators report the operating status of the power section and the integrated CANopen fieldbus interface, allowing maintenance technicians to quickly isolate system issues without external tools.
Advanced diagnostic analysis can be performed by reading the active error memory stored in registers C00168 and C00170. Connecting via EASY Starter software or the Keypad XT module grants access to recorded fault history, operational hours, and historical trip conditions for rapid root-cause analysis.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| DRV-READY | Green - Solid / Flashing / Off | Solid green indicates drive is ready for operation; flashing green indicates drive operation is active; off indicates not ready. |
| DRV-ERR | Red - Solid / Flashing | Solid or flashing red indicates a drive fault, warning, or error. Fast blinking indicates critical fault or hardware failure. |
| CAN-RUN | Green - Solid / Flashing | Indicates operational state of the integrated CANopen bus (Pre-Operational, Operational, or Stopped). |
| CAN-ERR | Red - Solid / Flashing | Indicates CANopen communication fault (Bus Off, Error Warning, or Node Guarding fault). |
Replacement and Spare Part Considerations
When selecting a spare drive, confirm that the model designation E84AVBDE5512SX0 matches the failed unit. Matching the exact part number 13318988 ensures identical electrical characteristics, including the 0.55 kW power rating, 3 A output current, and 230 V input configuration.
Replacing a damaged unit in the field requires minimal downtime when transferring the existing E84AYM256K memory module to the replacement drive. Swapping the memory module and control terminal block carries over all parameter settings and wire connections without forcing software downloads.
The Lenze 8400 StateLine series is in phase-out status. While direct spare units remain supported for existing installations, Lenze i550 series cabinet frequency inverters serve as the recommended successor path for new machine designs or full system retrofits.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short circuit / Earth fault | Short circuit at the motor terminals or earth fault in motor power cable. | Short circuit in motor winding, damaged motor cable, cable length too long, ground fault in motor lead. | Check motor and motor cable for short circuit or ground contact. Check motor cable length and shield connection. |
| OC5 | Overcurrent during acceleration / operation | Drive current exceeded the dynamic current limit. | Acceleration time set too short, excessive mechanical load or block, motor wrongly sized. | Extend acceleration time, check mechanics for stiffness or jam, check motor parameters. |
| OU | Overvoltage DC bus | DC-bus voltage has exceeded the upper shutdown threshold. | Regenerative energy from overhauling load or decelerating too fast without brake resistor; brake resistor defective or not connected. | Extend deceleration time (decel ramp), install or check braking resistor and brake chopper configuration. |
| LU | Undervoltage DC bus | DC-bus voltage fell below the lower operation threshold. | Mains supply voltage too low, supply phase loss, mains power failure, brief line drop. | Check supply line voltage, inspect power wiring, fuse and line switch. |
| OH1 | Heatsink temperature overtemperature | Heatsink temperature exceeded the maximum allowed limit. | Ambient temperature too high, fan obstructed or defective, insufficient ventilation space in control cabinet, heavy overload. | Clean heatsink cooling fins, check control cabinet cooling and fan, lower switching frequency or reduce load. |
| OH3 | Motor overtemperature | Motor temperature sensor (PTC/TK) detected excess motor thermal condition. | Motor overloaded, extended operation at low speed without forced cooling fan, defective thermal sensor wiring. | Allow motor to cool down, reduce load, check motor fan, verify sensor connection at terminals. |
| OH4 | Inside temperature overtemperature | Internal air temperature inside the drive housing exceeded permissible limit. | Control cabinet internal temperature too high, poor air circulation around drive. | Improve control cabinet ventilation, check cabinet fan and filter mats. |
| CE0 | CANopen communication fault | Communication failure or timeout on the integrated CANopen system bus. | Interrupted bus cable, wrong terminating resistor, baud rate mismatch, CAN master node offline. | Check CAN cabling and shielding, verify 120 Ohm termination resistors at bus ends, check node address and baud rate settings. |
| CE1 | Communication module fault | Communication timeout or error between inverter and optional fieldbus module. | Module improperly inserted, fieldbus connection broken, master PLC in stop state. | Check seating of extension module in drive slot, inspect fieldbus cable and PLC master status. |
| PIE | Parameter set error / Memory module fault | Invalid or corrupt parameter dataset on the inserted Memory Module or internal memory. | Memory module removed while powered on, damaged memory card, corrupted file parameter header. | Re-insert memory module securely, re-download parameter set using EASY Starter, or replace memory module if unrecoverable. |
| NMAX | Maximum speed exceeded | Actual motor speed exceeded the defined threshold value C00596. | Incorrect motor parameterization, drive overspeeding due to external overhauling load. | Verify motor nameplate data and speed limits, check mechanical load conditions. |
| H05 | Internal hardware fault | Internal board error or component failure detected during self-test. | Control board or power section failure, corrupted internal firmware. | Internal hardware fault — return unit for repair or replace inverter. |
Frequently Asked Questions
How do I transfer parameters to a replacement Lenze 13318988 drive?
You can transfer parameters directly by removing the E84AYM256K Memory Module from the original drive and inserting it into the replacement unit. Alternatively, parameter sets can be uploaded and downloaded using Lenze EASY Starter software or the optional Keypad XT.
What power supply is required for the E84AVBDE5512SX0 inverter?
The drive operates on either single-phase or three-phase 230 V / 240 V AC supply networks, with an acceptable line voltage range of 180 V to 264 V AC.
Can I connect this drive to networks other than CANopen?
Yes. While CANopen is built into the unit, an optional extension slot allows installation of fieldbus modules for PROFINET, PROFIBUS-DP, EtherCAT, and EtherNet/IP.
What does fault code H05 indicate on the drive display?
Fault code H05 indicates an internal hardware failure detected during internal self-tests. This error cannot be cleared by field adjustment and requires unit repair or replacement.
What is the official migration path if the 8400 StateLine series is phased out?
Lenze recommends the i550 series of cabinet frequency inverters as the official migration path for new panel designs or system upgrades.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.