Lenze 13435816 E82EV251_2C 8200 Vector Frequency Inverter 0.25kW

New 
On request
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 Vector | Series: 8200 Vector

The Lenze 13435816 E82EV251_2C is a compact 0.25 kW variable frequency drive from the 8200 Vector series, engineered to provide controlled speed and torque regulation for three-phase AC motors. Designed with an IP20 open chassis form factor, this drive accommodates supply voltages from 180 to 264 V AC across single-phase or three-phase power connections. It delivers a continuous output current of 1.7 A and supports up to 2.55 A for short peak load durations of up to 60 seconds, utilizing either V/f characteristic control or sensorless vector control across output frequencies from 0 to 480 Hz.

Integrating a spare drive into an existing control system requires matching both the hardware interface and the specific parameter set. The unit features a plug-in slot that accepts various function modules, enabling flexible terminal connections or direct fieldbus communication. When swapping an existing drive, parameters must be transferred from the original unit to the replacement using the optional Keypad XT module or software tools such as Lenze Global Drive Control or EASY Starter. Parameter sets can be backed up and cloned across units to replicate ramp times, switching frequencies, and control settings, while technical support from ABC Industrial Parts can assist maintenance teams with parameter extraction or pre-configuring spare units prior to installation.

Diagnostic information is displayed directly on the unit via status indicators and parameter registers. Dual LEDs provide immediate operational status, distinguishing between active drive operation, inhibited states, warning conditions, and trip faults. Detailed operational history can be queried through parameter C0013, while real-time drive status is monitored in register C0183 or through connected software. In the event of a rapid-flashing red LED indicating an internal memory checksum failure or EEPROM error, resetting the drive to factory defaults via parameter C0002 may clear the state; if hardware faults persist, ABC Industrial Parts provides tested exchange units and repair services to minimize system downtime.

Technical Specifications

ManufacturerLenze
Part Number13435816
Model / TypeE82EV251_2C
Product Family8200 Vector
Component TypeFrequency Inverter
Rated Power0.25 kW
Supply Voltage Range180 - 264 V AC
Input Phases1-phase / 3-phase 230 V AC
Continuous Output Current1.7 A
Max Output Current (60s Overload)2.55 A
Output Voltage Range0 - Supply Voltage (3-phase)
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz (adjustable 2 to 16 kHz)
Control ModeV/f Characteristic Control / Sensorless Vector Control
Power Loss20 W
Protection RatingIP20

Programming and Configuration

Drive commissioning and parameter management for the Lenze E82EV251_2C are managed through the optional Keypad XT module (E82ZBC) or PC-based software packages including Lenze Global Drive Control (GDC) version 4.0 or higher and Lenze EASY Starter. Parameter settings dictate motor acceleration ramps, switching frequencies between 2 kHz and 16 kHz, and control mode selections such as V/f characteristic curves or sensorless vector control.

To duplicate parameters during unit replacement, the Keypad XT module can copy and transfer complete parameter files directly from one drive to another without requiring a PC connection. When using GDC software, saved project files can be uploaded and written to replacement units over a direct programming connection. If a replacement drive exhibits unexpected behavior or parameter corruption, restoring default factory settings via parameter C0002 prepares the unit for clean parameter transfer.

Communication and System Integration

The E82EV251_2C basic unit relies on replaceable function modules attached to its front interface slot to establish control connections and network protocols. Supported options include the Standard I/O Function Module (E82ZAFSC) for discrete terminal control, as well as dedicated communication modules such as CANopen (E82ZAFCC) and PROFIBUS-DP (E82ZAFPC). The drive also supports Interbus and DeviceNet function modules to integrate seamlessly into broader industrial automation architecture.

Communication integrity is continuously monitored by the drive hardware. If fieldbus communication drops or experiences network interruptions, the drive flags a process data monitoring fault (CE1). Addressing bus faults requires verifying module seating on the basic unit connector, checking network cabling and termination, and confirming node addressing and baud rate parameters match the master controller configuration.

Diagnostics and Status Indication

Real-time monitoring on the E82EV251_2C frequency inverter is provided through visual LED indicators and accessible memory registers. The drive features dual-color status LEDs that signal operational modes, warnings, and trip conditions. Further diagnostic evaluation can be conducted via the Keypad XT interface, parameter C0013 fault history memory, status register C0183, or the online diagnostic window in Global Drive Control software.

First-line troubleshooting should include checking DC bus voltage status, motor phase wiring, and function module attachment. Internal errors such as memory failure or EEPROM checksum corruption are indicated by a rapidly flashing red LED, signalling that parameter restoration or hardware servicing is required.

Status LED Indicators

LEDColor/StatusMeaning
Green LEDGreen - SolidInverter operation enabled / drive running
Green LEDGreen - Flashing slowlyInverter inhibited (Inhibit active)
Red LEDRed - FlashingWarning state active
Red LEDRed - SolidFault state active (Trip condition)
Red LEDRed - Flashing rapidlyInternal hardware error / EEPROM fault (Service or repair required)

Replacement and Spare Part Considerations

When replacing a Lenze 8200 Vector drive model E82EV251_2C, the replacement unit must match the power output rating of 0.25 kW and supply voltage specifications of 180 to 264 V AC. Because the basic unit does not include built-in terminal blocks or fieldbus interfaces, the installed function module from the original drive—such as a Standard I/O or CANopen module—must be transferred directly to the replacement unit.

Before putting a spare drive into service, parameter configuration must be aligned with the machine's operating parameters. A blank or factory-default replacement unit will not operate correctly until the parameter set is transferred via Keypad XT or loaded using Global Drive Control software. Ensure that motor parameters, acceleration/deceleration times, and communication node settings are verified prior to starting motor operation.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short Circuit / Overcurrent during AccelerationShort circuit at the output or excess current acceleration spike exceeding maximum limit.Short circuit or earth fault in motor cable, acceleration time parameter set too short, motor dimensioned incorrectly.Check motor and wiring for short circuit / earth fault, increase acceleration time (C0012), check motor load.
OC2Overcurrent during DecelerationExcess output current during deceleration ramp.Deceleration time set too short, brake chopper not functioning or missing.Increase deceleration time (C0013), fit external brake resistor or brake module if required.
OC5Overcurrent at Constant SpeedOvercurrent condition detected during constant speed operation.Sudden load change, motor stalled, mechanical overload, earth fault.Check mechanical drive train for jamming, verify motor sizing, inspect motor cable insulation.
OUOvervoltage in DC BusDC bus voltage exceeded upper limit threshold.Regenerative energy from motor during deceleration, mains supply voltage too high.Increase deceleration time, install brake resistor or brake module, check mains supply voltage.
LUUndervoltage in DC BusDC bus voltage dropped below minimum threshold during operation.Mains supply voltage too low, mains phase failure, power supply interruption.Check supply voltage, verify mains fuses and supply cable connections.
OHHeatsink OvertemperatureInverter heatsink temperature exceeded allowable operating limit.Ambient temperature too high, cooling fan defective or blocked, inadequate ventilation, heatsink dirty.Clean heatsink fins, ensure adequate cabinet ventilation and clearances, check fan operation.
OH4Inverter Thermal Overload (I x t)Calculated thermal load of the inverter power section exceeded safety threshold.Continuous overload operation above rated output current.Reduce drive load, verify motor and drive sizing.
LP1Motor Phase FailureInterruption in one of the motor output phases detected.Loose motor cable terminal, open circuit in motor winding, motor contactor opened during operation.Check wiring between inverter and motor, check motor winding resistance, check motor contactor status.
EERInternal EEPROM FaultEEPROM memory checksum error or internal non-volatile memory failure.Data corruption in non-volatile memory, hardware fault on control board.Internal hardware/memory fault — reload factory default settings (C0002). If fault persists, unit requires repair or replacement.
CE0Communication Error with Function ModuleCommunication failure between inverter basic unit and attached function module.Function module loose or improperly seated on interface connector, module hardware failure.Turn off power, re-seat function module firmly onto basic unit, replace function module if error persists.
CE1Process Data Monitoring (CAN/Fieldbus Timeout)Timeout error in fieldbus communication process data reception.Interrupted fieldbus cabling, master PLC stopped or offline, bus configuration error.Check fieldbus cable and connectors, check master status, verify baud rate and node address settings.
NMAXSpeed Limit ExceededMotor speed exceeded maximum configured threshold (C0032).Incorrect motor parameter setting, field weakening setup incorrect, active load driving motor.Verify speed limit parameter settings, check load torque conditions.
P13Parameter Set ErrorInvalid parameter combination or corrupted parameter set loaded.Incomplete parameter transfer or incompatible firmware parameter set restore.Restore factory default setting (C0002) and re-commission parameters.

Frequently Asked Questions

What software is used to program and configure the Lenze 13435816 E82EV251_2C drive?

The drive can be configured using Lenze Global Drive Control (GDC) software version 4.0 or higher and Lenze EASY Starter. Alternatively, parameters can be adjusted directly on the drive using the plug-in Keypad XT module (E82ZBC).

How do I transfer parameters from a failed drive to a replacement unit?

Parameters can be copied onto a Keypad XT plug-in module from the active drive and transferred directly into the replacement unit. Alternatively, parameter projects can be saved and downloaded using Global Drive Control software over a PC interface connection.

What does a rapidly flashing red LED on the E82EV251_2C inverter indicate?

A rapidly flashing red LED indicates an internal hardware error or EEPROM memory fault. You can attempt to clear the fault by restoring factory default settings via parameter C0002; if the fault persists, internal board repair or unit replacement is required.

Can the Lenze E82EV251_2C operate on both single-phase and three-phase supply lines?

Yes, the E82EV251_2C supports dual input voltage options across a 180 to 264 V AC range, operating on either a single-phase 230V AC or three-phase 230V AC power supply.

How do I clear a communication error fault code such as CE0 or CE1?

For CE0 (module communication fault), power down the drive and firmly re-seat the function module on the basic unit connector. For CE1 (fieldbus timeout), inspect network cabling, verify master PLC status, and confirm node address and baud rate parameter settings.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.