Lenze E84AVSCE5512SX0 8400 StateLine C 0.55 kW Frequency Inverter
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze E84AVSCE5512SX0 is a 0.55 kW frequency inverter from the 8400 StateLine C series within the L-force 8400 product family. Designed for control cabinet installation with an IP20 protection rating, this drive operates on a 1-phase or 3-phase AC input supply ranging from 180 V AC to 264 V AC, producing a 0 to 230 V AC output with a continuous rated output current of 3.0 A and a maximum short-term output current of 4.5 A. It supports linear V/f, square-law V/f, sensorless vector control (VFCplus), and sensorless synchronous motor control (SLVC) modes across an output frequency range of 0 to 599 Hz with an 8 kHz switching frequency. Integrated Safe Torque Off (STO) functionality conforming to SIL 3 according to EN IEC 62061 and Performance Level e according to EN ISO 13849-1 provides certified safety suppression directly in the drive hardware.
For integration and commissioning, the unit features built-in CANopen system bus connectivity alongside control terminals providing 5 digital inputs, 1 digital output, 1 relay output, 1 analog input, and 1 analog output. Machine parameter settings are stored on the plug-in L-force Memory Module E84AYM01S, enabling tool-free parameter replication and rapid drive swapping without needing a PC connection. When software configuration or online monitoring is required, the front X400 diagnostic port accepts the EZAEBK100 keypad or the EZAEAG0001 USB diagnostic adapter for direct connection to Lenze EASY Starter software V2.0 or higher. When preparing a spare inverter, configuration extraction or parameter alignment can be verified with support from ABC Industrial Parts before restoring the drive to production service.
Diagnostic monitoring is handled through front panel status LEDs and internal parameter C00160 for active error reading. The DRV-READY and DRV-ERR LEDs communicate drive operating states and error conditions, while CAN-RUN and CAN-ERR report CANopen system bus activity. Common operational faults include OC1 for output short circuits or earth faults, OC2 for overcurrent during deceleration, OU for DC bus overvoltage, LU for undervoltage, OH for heatsink overtemperature, and CE0 for CAN communication errors. A persistent H05 code or solid red DRV-ERR indication indicates an internal hardware fault that cannot be cleared through field parameter adjustment. In these scenarios, replacing the unit or sourcing a fully tested exchange drive through ABC Industrial Parts offers a fast resolution to minimize process downtime.
Technical Specifications
| Manufacturer | Lenze |
| Part number | E84AVSCE5512SX0 |
| Model / Type | 8400 StateLine C |
| Product family | L-force 8400 |
| Component type | Frequency Inverter |
| Rated power | 0.55 kW |
| Supply voltage range | 180 - 264 V AC |
| Input phases | 1-phase / 3-phase |
| Rated output current | 3.0 A |
| Maximum output current | 4.5 A |
| Output voltage | 0 - 230 V AC |
| Output frequency range | 0 - 599 Hz |
| Switching frequency | 8 kHz |
| Control method | V/f linear, V/f square-law, VFCplus, SLVC |
| Safety function | Safe Torque Off (STO) SIL 3 / PL e |
| Onboard fieldbus | CANopen |
| Digital inputs | 5 |
| Digital outputs | 1 |
| Relay outputs | 1 |
| Analog inputs | 1 |
| Analog outputs | 1 |
| Protection rating | IP20 |
Programming and Configuration
Drive configuration for the Lenze E84AVSCE5512SX0 is performed using Lenze EASY Starter software version 2.0 or higher. Interfacing between a PC and the inverter is established via the EZAEAG0001 USB diagnostic adapter connected directly to the front X400 diagnostic port. Alternatively, basic parameter adjustments, state monitoring, and manual control can be handled without a computer using the EZAEBK100 plug-in keypad.
All parameter settings are stored externally on the removable L-force Memory Module E84AYM01S. This memory architecture allows complete dataset duplication across multiple drives and permits parameter sets to be transferred to a replacement unit instantly. If a drive parameter set becomes corrupted or requires initialization to a baseline state, writing value C00002 resets the inverter parameters to factory default settings.
Communication and System Integration
The Lenze E84AVSCE5512SX0 features an integrated CANopen system bus interface directly on the main control unit. This onboard interface facilitates real-time velocity commands, drive control words, cyclic status feedback, and parameterization across the machine network without requiring an optional fieldbus card.
For integration into broader automation networks, the inverter includes an expansion slot that accepts optional plug-in communication modules. Supported options include the E84AYCPM module for PROFIBUS, E84AYCER for PROFINET, E84AYCEO for EtherNet/IP, and E84AYCET for EtherCAT, allowing connection to central controllers while retaining native diagnostic and parameter capabilities.
Diagnostics and Status Indication
Status monitoring on the Lenze E84AVSCE5512SX0 is provided by four front-mounted LED indicators: DRV-READY, DRV-ERR, CAN-RUN, and CAN-ERR. These indicators give immediate visual feedback on drive execution state, fault conditions, and CANopen network status. Advanced fault inquiry can be performed by reading parameter C00160 (Current error) using EASY Starter software or via the EZAEBK100 keypad connected to the X400 port.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| DRV-READY | Green - Solid / Flashing | Green ON: Drive is ready for operation / active. Green flashing: Drive enabled/running. |
| DRV-ERR | Red - Solid / Flashing | Red flashing: Warning active. Red ON: Fault / Error condition active (drive inhibited). Permanently red: Internal hardware fault. |
| CAN-RUN | Green - Solid / Flashing | Green ON: CANopen Operational state. Flashing: Pre-Operational / Stopped state. |
| CAN-ERR | Red - Solid / Flashing | Red ON / Flashing: CANopen bus error / Bus off state. |
Replacement and Spare Part Considerations
When replacing an existing Lenze E84AVSCE5512SX0 frequency inverter, hardware installation requires matching the 0.55 kW rating and checking that incoming power is within 180 to 264 V AC. Parameter transfer is completed without a PC by transferring the L-force Memory Module E84AYM01S from the failed unit directly into the replacement inverter prior to powering on.
Ensure that the safety control wiring to the Safe Torque Off (STO) terminals is reconnected correctly to preserve certified SIL 3 / PL e operation. If planning system modernization or migrating away from the 8400 StateLine C series, Lenze provides a direct migration route to the Lenze i550 cabinet inverter series, specifically model i55AE155B1001000S.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short circuit / Earth fault | Excessive motor output current detected during acceleration or steady operation. | Short circuit in motor cable, earth fault in motor winding, motor power rating too large for drive, acceleration ramp too short. | Check motor and motor cable for short circuits/earth fault; adjust acceleration time in parameter settings. |
| OC2 | Overcurrent during deceleration | Excessive motor output current detected during braking/deceleration. | Deceleration ramp set too short, generatoric power too high. | Increase deceleration ramp time; install or verify braking resistor connection if applicable. |
| OC5 | I x t Overload (Drive) | Continuous current overload limit exceeded for thermal protection of the inverter power section. | Drive operating continuously above rated output current, mechanical load blocked or excessive. | Check mechanical load; check sizing of inverter and motor. |
| OU | DC bus overvoltage | Intermediate circuit DC bus voltage exceeds upper threshold limit. | Excessive regenerative energy from motor during deceleration, deceleration time too short, mains input voltage too high. | Increase deceleration time; check mains voltage; connect braking resistor if required. |
| LU | DC bus undervoltage | Intermediate circuit DC bus voltage dropped below minimum operating limit. | Mains supply failure, supply phase missing, main power interrupted during operation. | Check mains voltage supply and fuses; check incoming AC power wiring. |
| OH | Heatsink overtemperature | Internal heatsink temperature exceeded the maximum allowed temperature limit. | Ambient temperature too high, cooling fan failed or blocked, dirty heatsink cooling fins, insufficient control cabinet ventilation. | Clean heatsink fins; ensure adequate airflow in control cabinet; check internal fan. |
| OH4 | Motor thermal overload (I2t / PTC) | Motor temperature sensor or software I2t calculation triggered motor overtemperature error. | Motor overloaded, motor cooling compromised, PTC thermal contact opened. | Allow motor to cool down; check motor load and motor thermal sensor connections. |
| CE0 | Communication error (System bus / CAN) | Loss of communication on built-in CANopen system bus or fieldbus interface. | Broken communication cable, incorrect baud rate setting, bus termination missing, master controller offline. | Check CANbus wiring, shielding, and terminating resistors; verify node ID and baud rate settings. |
| H05 | Internal hardware fault | Internal power supply or microcontroller failure detected during self-test. | Internal component failure, corrupted internal EEPROM, control card failure. | Perform power cycle. If fault persists: internal hardware fault — replace the unit or return to Lenze service for repair. |
| PI | Parameter set error | Invalid or corrupted parameter dataset loaded from memory module. | Memory module removed during write operation, incompatible parameter set version. | Re-initialize parameters to factory default setting (C00002) or download valid parameter set from EASY Starter. |
Frequently Asked Questions
How do I transfer parameters to a replacement Lenze E84AVSCE5512SX0 inverter?
Remove the plug-in L-force Memory Module E84AYM01S from the original drive and insert it into the replacement unit. The parameter set, motor configuration, and network settings will load automatically when power is applied.
Which software and adapter are required to connect a PC to the drive?
Configuration requires Lenze EASY Starter software V2.0 or higher along with the EZAEAG0001 USB diagnostic adapter connected to the X400 diagnostic port.
What does a permanently red DRV-ERR LED signify?
A permanently illuminated red DRV-ERR LED indicates an unrecoverable internal hardware fault (such as fault code H05) that requires power cycling or hardware repair/replacement.
Does the E84AVSCE5512SX0 inverter support optional fieldbus communication?
Yes. Beyond the standard onboard CANopen interface, plug-in modules support PROFIBUS (E84AYCPM), PROFINET (E84AYCER), EtherNet/IP (E84AYCEO), and EtherCAT (E84AYCET).
What is the official Lenze migration path for this drive?
The recommended migration model for upgrading from the 0.55 kW 8400 StateLine C inverter is the Lenze i550 cabinet inverter model i55AE155B1001000S.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.



