Lenze 00451557 EVD4905-E Servo Positioning Controller

New 
On request
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: EV&D 4900

The Lenze 00451557 EVD4905-E is a digital servo positioning controller and drive unit from the EV&D 4900 family, engineered for closed-loop position and speed control of AC brushless servo motors up to 5.5 kW. Operating on a 3-phase AC input range of 320 V to 528 V AC with a nominal rating of 400 V AC, the drive delivers a continuous output current of 12 A and dynamic peak output capability of 24 A for 5 seconds to handle demanding acceleration cycles. Featuring an 8 kHz switching frequency and a maximum output frequency of 480 Hz, this controller provides dynamic torque performance suitable for automated indexing, point-to-point positioning, and multi-axis synchronised drive systems.

For system interface and feedback, the unit is equipped with an integrated 500 kbit/s CAN system bus for master-slave drive coordination, a female 9-pin Sub-D resolver interface (X7), and a modular expansion slot supporting optional communication adapters like the PROFIBUS-DP EMF2133IB card or LECOM-A RS232 EMF2102IBV001 module. Putting a spare unit into service requires parameter alignment, as the controller relies on internal EEPROM memory to store up to two operating datasets. Parameter transfer can be completed directly using the Operating Module Keypad XT (EMF2102IBC) or uploaded via Lenze Global Drive Control (GDC) software versions 4.x or 5.x. Technical support teams at ABC Industrial Parts can assist with pre-tested replacement units and parameter preparation to minimize downtime during installation.

Drive operational status is indicated visually on the front housing by a green power LED for operational readiness and a red TRIP LED for fault conditions. Real-time diagnostics, error logs, and parameter monitoring are accessible through the Keypad XT display, GDC software online monitoring, or CAN system bus diagnostic status outputs. Internal protection monitors detect conditions such as overcurrent (OC1, OC2, OC3), DC bus overvoltage or undervoltage (OU, LU), heatsink and cabinet overheating (OH, OH4, OH5), resolver signal errors (Sd3), positioning errors (PR), or CANbus communication failure (H05). Persistent memory faults like EE or hardware power stage failure indicate internal defects that cannot be serviced in the field, making drive repair or unit replacement through ABC Industrial Parts the most efficient path back to full production.

Technical Specifications

Supply Voltage400 V AC
Supply Voltage Range320 - 528 V AC
Continuous Rated Current12 A
Peak Output Current24 A
Rated Power Output5.5 kW
Switching Frequency8 kHz
Maximum Output Frequency480 Hz
System Bus Communication Rate500 kbit/s
Position Feedback InterfaceResolver (Sub-D 9-pin female)

Programming and Configuration

The Lenze EVD4905-E servo positioning controller utilizes internal non-volatile EEPROM memory to store up to two complete parameter sets. Drive configuration, positioning profiles, axis scaling, and motor speed control parameters are managed using Lenze Global Drive Control (GDC) software version 4.x or 5.x. Connection to a PC for software commissioning is established through a LECOM serial adapter or supported fieldbus module.

For rapid field replacement without a laptop on the factory floor, parameter duplication can be performed directly using the Lenze Keypad XT (EMF2102IBC). The Keypad XT attaches directly to the front interface slot of the drive, enabling maintenance technicians to upload parameter sets from an operational unit and transfer them into a replacement drive. This parameter transfer preserves motor alignment data, application limits, and control loop configurations.

Communication and System Integration

Network integration for the EVD4905-E is centered on its onboard CAN system bus interface operating at 500 kbit/s. Supporting CANopen-compatible communication, the system bus handles multi-axis motion synchronization, real-time control commands, and cross-axis data exchange between master controllers and slave drives without requiring auxiliary motion control cards.

For integration into fieldbus networks, the drive features a modular expansion slot. Installing optional interface modules such as the PROFIBUS-DP communication module (EMF2133IB) or the LECOM-A RS232 adapter (EMF2102IBV001) allows seamless integration with centralized PLC control architecture. Motor position feedback is routed through the standard female 9-pin Sub-D connector on interface X7 for resolver-equipped AC servo motors.

Diagnostics and Status Indication

Visual status monitoring on the Lenze EVD4905-E controller is provided by two front-panel LED indicators. A solid green LED indicates active line power and operational readiness. A solid or flashing red LED alerts operators to an active TRIP status or unacknowledged fault condition that has halted drive execution.

Detailed diagnostics are accessible via the Keypad XT (EMF2102IBC) error menu, which logs trip events and displays active fault codes. Additionally, drive parameters, fault history, and dynamic operating variables can be monitored online through Global Drive Control (GDC) engineering software or over the CAN system bus interface.

Status LED Indicators

LEDColor/StatusMeaning
Green LEDGreen - SolidReady for operation / Power ON
Red LEDRed - Solid/FlashingTRIP active / Fault condition present

Replacement and Spare Part Considerations

When replacing a Lenze EVD4905-E servo controller (part number 00451557), verify that the replacement drive matches the required electrical specifications: 5.5 kW power rating, 12 A continuous output current, and 320–528 V AC operating voltage range. Replacement units cannot operate out-of-the-box without transferring the internal parameter set configured for the target machine.

Parameter sets must be copied from the original drive to the replacement unit using either a Keypad XT (EMF2102IBC) or Global Drive Control (GDC) software V4.x/V5.x. Before restarting production, verify that CAN system bus node addresses match network documentation, confirm that 120 Ohm termination resistors are installed at both ends of the CAN bus line, and check that resolver cabling on connector X7 has intact shielding.

In situations where an old drive displays an unrecoverable EEPROM memory failure (fault EE) or immediate short-circuit trips (fault OC1) with the motor disconnected, internal hardware damage has occurred. Board-level repair or swapping in a fully tested spare unit allows fast restoration of system operation without re-engineering the application controls.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short Circuit / Earth FaultShort circuit at motor terminals or earth fault in motor wiring.Short circuit in motor cable, motor winding fault, ground fault.Check motor wiring and insulation test motor. If fault occurs immediately with motor disconnected, power stage hardware fault requires service.
OC2Earth Fault During OperationGround fault current detected during drive execution.Damaged motor insulation or water in motor junction box.Inspect cable shielding and motor ground connections.
OC3Overcurrent AccelerationMotor current limit exceeded during dynamic acceleration.Acceleration time too short, mechanical block or overload.Increase acceleration ramp time, reduce motor load, verify motor parameters.
OUDC Bus OvervoltageDC bus voltage exceeded upper limit (>770 V DC).Braking energy too high, deceleration ramp too short, brake chopper/resistor missing or defective.Increase deceleration ramp, connect or check external brake resistor.
LUDC Bus UndervoltageDC bus voltage dropped below minimum limit (<400 V DC).Mains supply failure, supply phase missing, main contactor open.Check mains voltage supply and input fuses.
OHDrive OverheatingHeatsink temperature exceeded allowable threshold.Inadequate cabinet cooling, dirty heatsink, internal fan failure.Clean heatsink, check fan operation and ambient temperature.
OH4Cabinet OverheatingDrive interior / ambient temperature high limit exceeded.Ambient temperature in control cabinet too high.Improve enclosure ventilation or air conditioning.
OH5Motor OverheatingMotor thermal contact / PTC sensor triggered overload.Continuous motor overload, blocked cooling air on motor.Allow motor to cool, reduce mechanical load, verify thermal sensor cable connection.
Sd3Resolver Feedback ErrorSignal loss or broken cable on resolver interface X7.Resolver cable disconnected, damaged cable shield, defective resolver.Inspect resolver wiring and connector X7, check shielding and grounding.
EEEEPROM FaultInternal EEPROM read/write memory fault.Corrupted non-volatile memory or hardware defect.Reload factory default settings. If fault persists, internal hardware defect - return unit for repair or replace unit.
H05System Bus (CAN) Communication FaultCANbus message timeout or bus-off state.Incorrect baud rate, missing bus termination resistor (120 Ohm), damaged CAN cable.Check CANbus cable, termination resistors, and node address settings.
PRProgram / Positioning ErrorTarget position out of range or positioning profile fault.Software limit switch reached, invalid target position received.Verify position profile settings and target values in GDC software.

Frequently Asked Questions

How do I transfer parameters to a replacement Lenze EVD4905-E controller?

Parameters can be transferred using the Keypad XT module (EMF2102IBC) by copying parameter sets directly from drive memory without a PC. Alternatively, configuration files can be uploaded and restored via Global Drive Control (GDC) software versions 4.x or 5.x over a serial or fieldbus connection.

What engineering software is required to configure the EVD4905-E drive?

The EVD4905-E is configured using Lenze Global Drive Control (GDC) software versions 4.x or 5.x. The software provides tools for parameter management, positioning profile setup, dynamic tuning, and fault log analysis.

What motor feedback interface is built into the EVD4905-E?

The controller features a dedicated 9-pin female Sub-D connector on interface X7 designed to interface with standard AC brushless servo motors equipped with resolver position feedback.

What causes fault code OC1 on the Lenze EVD4905-E?

Fault code OC1 indicates a short circuit or ground fault in the motor cabling or windings. If fault OC1 occurs immediately upon powering up with the motor cable disconnected from the drive, an internal power stage hardware fault is present.

How is the built-in CAN system bus interface configured?

The integrated CAN system bus operates at 500 kbit/s for multi-axis synchronization. Correct network performance requires setting matching node addresses, verifying cable wiring, and fitting 120 Ohm termination resistors at both physical ends of the CAN bus line.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.