Indramat R911285595 FWA-ECODR3-FGP-03VRS-MS Firmware Module
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Indramat R911285595, designated by type code FWA-ECODR3-FGP-03VRS-MS, is a dedicated firmware module engineered for the ECODRIVE03 drive controller platform by Bosch Rexroth Indramat. Functioning as a non-volatile hardware memory card pre-loaded with drive operating software, this module delivers the core instruction set required to run compatible host drive controllers in automated machinery. Inserting the unit into the host drive's plug-in firmware slot activates the Fieldbus General Profile (FGP) functional group, enabling coordinated motion control and fieldbus integration across factory automation environments.
Commissioning or replacing the unit centers on its direct plug-in card architecture and broad platform compatibility across Indramat DKC03, DKC04, DKC05, and DKC06 series drive controllers. Because system instructions and parameters reside in non-volatile hardware memory without needing battery backup, maintenance personnel can execute a direct card swap between host units without re-flashing software or employing external programming cables. Swapping an existing FWA-ECODR3-FGP-03VRS-MS card into a donor drive preserves network parameters and software settings. ABC Industrial Parts supports maintenance operations requiring tested replacement firmware modules to maintain continuous production readiness.
System state monitoring and fault diagnostics for the module are handled via the host DKC drive controller front panel display and through the fieldbus software interface. Integrated multilingual support (MS) allows operators to perform parameter adjustments and read system status reports in standard international languages. If a host controller reports firmware read errors or network communication faults, verifying proper card seating within the slot is the recommended initial check. Internal memory or board-level hardware failures on the firmware card are not field-repairable, making a pre-tested exchange card from ABC Industrial Parts the quickest route to recovering drive operation.
Technical Specifications
| Manufacturer | Bosch Rexroth Indramat |
| Part Number | R911285595 |
| Model / Type Code | FWA-ECODR3-FGP-03VRS-MS |
| Product Family | ECODRIVE03 |
| Component Type | Firmware Module |
| Function Group Profile | Fieldbus General Profile (FGP) |
| Firmware Version | 03VRS |
| Language Package | Multilingual (MS) |
| Memory Type | Non-volatile Hardware Module |
| Mounting Style | Plug-in Firmware Slot |
| Host Drive Compatibility | DKC03, DKC04, DKC05, DKC06 Series |
Programming and Configuration
The FWA-ECODR3-FGP-03VRS-MS firmware card contains release version 03VRS software, providing the embedded control instructions required by ECODRIVE03 host controllers. Utilizing non-volatile hardware memory architecture, the module maintains stored firmware code and operational parameters permanently, preventing data loss during extended power outages or storage.
System configuration and diagnostics are streamlined through built-in multilingual (MS) language support. Technicians interfacing with the host drive via fieldbus software or control panels can access parameter lists, operation menus, and diagnostic indicators in international standard languages without requiring external software language tools.
Communication and System Integration
This firmware card enables the Fieldbus General Profile (FGP) functional group on host ECODRIVE03 drive units. The FGP capability establishes the standardized fieldbus communication interface necessary for transferring motion commands, status bits, and operational data between the drive and higher-level automation networks.
The module is designed for universal integration across multiple hardware configurations within the DKC drive family. It inserts directly into DKC03, DKC04, DKC05, and DKC06 series controllers, ensuring uniform fieldbus communication capabilities across varied machine sections and drive power ratings.
Diagnostics and Status Indication
Diagnostic readout for the R911285595 module relies on the host DKC controller hardware. Active system states, operational parameters, and error indications are output directly through the front panel digital display on the drive controller.
Advanced network and drive diagnostics are accessible via the host controller software interface over the fieldbus network. The multilingual software package renders all status reports and fieldbus diagnostics in standard operating languages for efficient fault identification.
Replacement and Spare Part Considerations
When replacing an ECODRIVE03 firmware module, confirm that the complete type designation matches FWA-ECODR3-FGP-03VRS-MS. Verifying the functional profile (FGP), firmware release (03VRS), and language package (MS) ensures full network compatibility and parameter alignment with the target host drive.
The plug-in architecture simplifies hardware swapping during maintenance. Physical transfer of the non-volatile firmware card from a failed controller into a functional replacement drive retains fieldbus configuration and operational parameters without requiring external software flashing or PC-based tools.
Frequently Asked Questions
Which Indramat drive controllers support the R911285595 firmware module?
The R911285595 (FWA-ECODR3-FGP-03VRS-MS) module is compatible with Indramat ECODRIVE03 platform controllers, specifically DKC03, DKC04, DKC05, and DKC06 series host drives.
Does the firmware module require a backup battery to hold memory?
No, the module utilizes non-volatile hardware memory architecture, which retains firmware instructions and operating parameters without needing battery power.
What function group profile is enabled by this module?
This module activates the Fieldbus General Profile (FGP), providing standardized fieldbus network communication for the host drive controller.
Is software flashing required when installing a spare firmware card?
No, the pre-loaded non-volatile card can be inserted directly into a compatible host drive controller, transferring parameters and control software without external re-flashing.
How are system diagnostics viewed for this component?
Diagnostics are displayed on the host DKC drive controller front panel display or via the host controller fieldbus software interface in multiple supported languages.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Indramat.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.



