Lenze 13201037 E82ZAFPC001 PROFIBUS-DP Communication Module
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze 13201037, model identifier E82ZAFPC001, is a dedicated PROFIBUS-DP fieldbus communication module designed for the Lenze 8200 Vector frequency inverter family. Functioning as an interface between variable speed drives and centralized automated control systems, this module enables inverters to receive remote run commands, velocity setpoints, and parameter adjustments across an industrial network. The unit features a plug-in form factor that mounts directly onto the front panel option slot of an 8200 Vector drive host, eliminating the need for external mounting accessories or intermediate wiring adapters. Designed for installation inside standard control cabinets, it carries an IP20 protection rating and operates on an external 24 V DC supply drawing 80 mA of current.
Network integration is accomplished through a standardized 9-pin Sub-D connection, replacing complex hardwired terminal signals with high-speed digital fieldbus communication. Putting a replacement E82ZAFPC001 unit into service involves mounting the module into the host drive's option slot, connecting the fieldbus line, and ensuring that network parameters align with the host controller, such as a Siemens S7 PLC master. When installing a replacement module, node address configuration and host drive parameters must be verified to ensure proper communication and control handshaking. Specialists at ABC Industrial Parts can support maintenance teams with sourcing tested replacement modules and providing technical guidance for drive interface commissioning.
Fieldbus communication issues typically manifest as network fault alarms on the central PLC host or a loss of remote drive responsiveness. Initial field checks should include confirming physical cable attachment at the 9-pin Sub-D socket, checking fieldbus shielding, and verifying the presence of stable 24 V DC power. Additionally, technicians should ensure that network node addresses match the PLC configuration and that line termination resistors are correctly positioned on the physical PROFIBUS segment. Because internal hardware components on fieldbus interface boards are not field-serviceable, replacing a damaged module with a fully tested exchange unit through ABC Industrial Parts provides a reliable solution for restoring operational throughput in packaging, material handling, and factory automation applications.
Technical Specifications
| Manufacturer | Lenze |
| Part number | 13201037 |
| Model / type | E82ZAFPC001 |
| Component type | Communication Module |
| Product family | 8200 Vector |
| Communication protocol | PROFIBUS-DP |
| Connector type | 9-pin Sub-D |
| Supply voltage | 24 V DC |
| Rated current | 80 mA |
| Protection rating | IP20 |
Communication and System Integration
The Lenze E82ZAFPC001 module equips 8200 Vector frequency inverters with a direct interface to PROFIBUS-DP industrial fieldbus networks. By establishing connection to a central PLC, such as a Siemens S7 master controller, the module allows the drive to be fully integrated into automated motion sequences. Physical network wiring connects directly to the unit using a industry-standard 9-pin Sub-D socket, reducing hardwired control cabling and simplifying control cabinet organization.
Using the PROFIBUS-DP communication protocol, the interface supports fast cyclic data exchange for primary operating commands. This includes real-time transmission of start and stop signals, velocity setpoints, operational status telemetry, and drive fault indications. In addition to cyclic control data, the module enables remote parameterization and diagnostic access, allowing operators to modify drive settings and evaluate motor performance directly from the central control environment.
Mechanical and electrical installation is designed for direct compatibility with the 8200 Vector drive host. The card plugs directly into the drive's front option slot without external wiring harnesses. Power for the communication circuit is drawn from a 24 V DC supply at 80 mA, maintaining low power consumption and minimal heat dissipation inside IP20-rated enclosures.
Replacement and Spare Part Considerations
When replacing an existing Lenze 13201037 (E82ZAFPC001) module, ensure that power to the host frequency inverter is fully isolated before removing or inserting the communication card into the front option slot. Verify that the replacement part number and model identifier match the original unit to ensure hardware compatibility with the 8200 Vector inverter.
A replacement module requires proper fieldbus address alignment to communicate on the network. Ensure that the station address assigned to the replacement E82ZAFPC001 matches the hardware node address configured in the master PLC project. If the address or bus timing parameters differ from the original setup, the master controller will fail to establish cyclic data exchange with the drive.
Following physical installation and cable connection via the 9-pin Sub-D connector, check the parameter settings on the host 8200 Vector inverter. The drive must be configured to take its control commands and speed setpoints from the option slot interface rather than local terminal strips or digital keypads.
Frequently Asked Questions
Which drive series is the Lenze 13201037 module compatible with?
The Lenze 13201037 (model E82ZAFPC001) is designed specifically for direct mounting onto Lenze 8200 Vector series frequency inverters.
What network protocol does the E82ZAFPC001 communication module support?
The module operates using the PROFIBUS-DP fieldbus protocol, enabling centralized control and parameter monitoring from master controllers such as Siemens S7 PLCs.
What connector type is used for network connection?
Network cables connect to the E82ZAFPC001 module using a standard 9-pin Sub-D interface.
What are the electrical power requirements for this module?
The module operates on a supply voltage of 24 V DC and draws a rated current of 80 mA.
What steps are required when replacing a failed E82ZAFPC001 module?
To replace the module, isolate power to the inverter, plug the spare card into the 8200 Vector front option slot, attach the 9-pin Sub-D cable, verify the 24 V DC supply, and ensure that the node address and inverter control parameters match the host PLC network configuration.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.