Lenze 00450898 EVS9326-KHV531 9300 Servo Inverter

New 
1 available for direct collection
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo | Series: 9300 Servo

The Lenze 00450898 EVS9326-KHV531 is an 11 kW servo inverter belonging to the Lenze 9300 Servo family, engineered for precise speed and position control of synchronous and asynchronous servo motors. Operating on a 3-phase AC supply voltage between 320 V AC and 528 V AC (nominal 400 V AC to 480 V AC), this drive delivers a rated continuous output current of 24 A and a peak current capability of 36 A for up to 60 seconds. Designed with field-oriented vector control and an IP20 enclosure rating, the unit features a cold-plate thermal construction (KH designation) that transfers heat directly to external mounting surfaces, reducing cabinet enclosure depth and minimizing internal cooling airflow needs.

For inter-drive communication and system integration, the EVS9326-KHV531 incorporates a built-in CAN-based Lenze System Bus at terminal X4 along with a front Automation Interface (AIF) slot. This modular slot accepts option devices including the EMF2133IB PROFIBUS module, EMF2177IB System Bus Adapter, LECOM RS232/RS485 interfaces, INTERBUS modules, or the EMZ9371BC XT Keypad. Placing a replacement drive into service requires transferring the parameter dataset saved in internal EEPROM memory, which is executed using Global Drive Control (GDC) software or direct keypad backup restore. When transferring parameters or attempting parameter extraction from a faulty donor unit, technical support from ABC Industrial Parts can help ensure configured settings match the target axis requirements.

Diagnostic indication is provided on the drive panel via a green DRIVE READY status light and a red TRIP / FAULT status light, while detailed trip histories and fault records can be retrieved from parameter C0168 via GDC software or keypad. Initial troubleshooting steps should cover main line supply across L1, L2, and L3, motor thermistor connections at terminals T1/T2, feedback wiring at Sub-D terminal X7 and terminal X8, and proper 120-ohm termination on the CAN bus. When hardware fault codes such as EEr, EEr2, or H05 indicate internal control board or memory corruption, on-site board repairs are not practical; sourcing a tested exchange drive from ABC Industrial Parts offers a fast and effective way to restore production.

Technical Specifications

ManufacturerLenze
Part Number00450898
Model / TypeEVS9326-KHV531
Product Family9300 Servo
Component TypeServo Inverter
Rated Power11 kW
Supply Voltage3x 400 / 480 V AC
Supply Voltage Range320 - 528 V AC
Rated Continuous Output Current24 A
Peak Output Current36 A (150% for 60 s)
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz
Control MethodField-oriented vector control
Digital Inputs8
Digital Outputs4
Analog Inputs2
Analog Outputs2
Cooling / Mounting TypeCold Plate (KH version)
IP Protection RatingIP20

Programming and Configuration

The Lenze 00450898 EVS9326-KHV531 servo drive employs field-oriented vector control to run synchronous and asynchronous servo motors. Commissioning, diagnostic monitoring, and parameter adjustment are performed using Lenze Global Drive Control (GDC) software connected via a suitable communication interface or locally via the plug-in EMZ9371BC XT Keypad attached to the front Automation Interface (AIF) slot.

All operating parameters, feedback configurations, gain values, and fieldbus mappings are retained inside non-volatile internal EEPROM memory. When replacing an existing drive, the configured parameter set must be uploaded from the original unit or project file and downloaded into the replacement unit. If parameter corruptions or write errors occur during startup, reloading factory default settings or restoring a verified backup dataset resets the internal controller logic.

Communication and System Integration

System connectivity in the EVS9326-KHV531 is built around an integrated Lenze System Bus (CAN/CANopen) accessed through terminal connection X4. This bus interface allows fast inter-drive communication, parameter transfer, and multi-axis synchronisation without requiring extra communication cards. End nodes on the CAN system bus require 120-ohm termination resistors across the signal lines.

For higher-level network connectivity, the front Automation Interface (AIF) slot accommodates optional fieldbus communication modules, such as the EMF2133IB PROFIBUS-DP card, EMF2177IB System Bus Adapter, INTERBUS modules, or LECOM RS232/RS485 adapters. Motor feedback devices connect to dedicated hardware ports, including Sub-D connector X7 for resolvers, terminal X8 for incremental encoders, and terminals T1/T2 for motor temperature thermistor monitoring.

Diagnostics and Status Indication

Operational status and trip alerts are displayed on the front panel via LED indicators. Active fault conditions, warnings, and historic trip records are stored in parameter C0168, which can be read using Global Drive Control software or the EMZ9371BC keypad module. Diagnostic parameters also allow real-time checking of status words, motor phase currents, and internal DC bus voltage levels.

Status LED Indicators

LEDColor/StatusMeaning
DRIVE READYGreen - Solid / FlashingSolid ON = Drive ready/enabled; Slow flashing (1 Hz) = Drive inhibited (CINH); Fast flashing (2 Hz) = Parameter transfer active.
TRIP / FAULTRed - Solid / FlashingSolid ON = Drive in TRIP fault condition; Flashing = Warning active or error code pending.

Replacement and Spare Part Considerations

When replacing an existing Lenze 00450898 EVS9326-KHV531 drive, verifying the exact part number and model variant is critical. The "KH" suffix denotes the cold-plate heat sink construction, which relies on direct contact with an external cooling interface. Before mounting the spare unit, the cold-plate interface surface must be thoroughly cleaned and thermal compound applied to prevent overtemperature trips (OH).

In addition to mechanical mounting, all configuration parameters must be transferred from the original drive to the replacement using Global Drive Control software or the EMZ9371BC keypad. Optional fieldbus modules inserted into the front AIF slot, such as the EMF2133IB PROFIBUS module, must be transferred to the replacement unit and checked for proper mechanical seating.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuit / OvercurrentShort circuit at the output terminals or excessive motor current detected.Short circuit in motor cable, motor winding fault, ground fault, or incorrect motor parameterization.Check motor and motor cables for short circuit or insulation damage; verify motor data settings.
OC2Earth fault / Ground faultEarth fault current detected during acceleration or operation.Ground connection in motor cable or motor winding, capacitive cable charging current.Check motor and wiring for ground faults; reduce motor cable length or fit output choke.
OC5I*t overload / Motor overcurrentDrive overload during acceleration or continuous heavy operation.Excessive mechanical load, acceleration time too short, motor stuck.Check load mechanics; increase acceleration time; reduce mechanical load.
OUDC Bus OvervoltageDC bus voltage exceeded upper voltage limit threshold.Excessive regenerative energy during deceleration, brake chopper defective or brake resistor open circuit.Increase deceleration time; verify brake chopper and external brake resistor connection.
LUDC Bus UndervoltageDC bus voltage dropped below minimum operating limit.Mains supply failure, mains supply voltage too low, phase failure, or blown input fuse.Check mains line voltage, line fuses, and main power supply connections.
OHHeatsink OvertemperatureDrive heatsink temperature exceeded allowable threshold limit.Insufficient cabinet cooling, clogged cooling fan, cold-plate thermal interface degradation, excessive ambient temperature.Clean heat sink / cold plate contact area; verify cabinet cooling fan function and ambient temperature.
OH4Motor Overtemperature (PTC)Motor temperature sensor (PTC/TK) reported excessive temperature on terminals T1/T2.Motor thermal overload, cooling fan failure on motor, broken sensor cable.Allow motor to cool down; check motor loading, motor cooling fan, and PTC wiring.
OH7Internal Drive OvertemperatureTemperature inside the drive housing exceeds maximum permissible value.Cabinet ambient temperature too high, inadequate ventilation inside cabinet.Improve enclosure ventilation and ambient cooling.
OH8Motor Sensor Wire BreakWire break or open circuit on motor temperature sensor input (T1/T2).Disconnect or open line on motor thermistor wiring.Check wiring to thermistor input terminals T1 and T2.
CE0AIF Communication ErrorCommunication failure between drive controller and plug-in Automation Interface module.AIF module missing, loose connection, or fieldbus network timeout.Check physical seating of AIF module in front slot; check fieldbus cable.
CE1Process Data Fault AIF Channel 1Process data transfer timeout on AIF channel 1.Master controller stopped sending process data, network interruption.Check PLC master status, fieldbus cabling, and communication timeouts.
CE2Process Data Fault AIF Channel 2Process data transfer timeout on AIF channel 2.Master controller stopped cyclic data transmission.Check PLC application program and fieldbus interface.
CE3Process Data Fault AIF Channel 3Process data transfer timeout on AIF channel 3.Cyclic communication failure.Check fieldbus cyclic process data assignment and master run status.
CE4AIF Bus Off / Telegram ErrorFieldbus communication error on automation interface module.Excessive electrical noise, baud rate mismatch, faulty fieldbus cabling.Check bus termination resistors, fieldbus baud rate, shielding, and cable routing.
C013System Bus (CAN) FaultSystem bus (CAN) communication interrupt or bus-off condition on X4 terminal.CAN bus wiring disconnected, missing termination resistor, node address conflict, baud rate mismatch.Check CAN bus wiring, 120-ohm termination resistors on end nodes, and CAN baud rate configuration.
EErEEPROM Memory ErrorInternal EEPROM checksum error or parameter read fault.EEPROM hardware corruption or failure during parameter save.Internal hardware fault — reload default parameters; if error persists, internal control board fault requires factory repair/replacement.
EEr1EEPROM Checksum ErrorStored parameter set checksum mismatch on startup.Power interruption during parameter save operation.Restore parameters from backup or reload factory default dataset; replace drive if persistent.
EEr2EEPROM Write ErrorUnable to write parameter dataset to internal EEPROM.Internal EEPROM chip failure or hardware board defect.Internal hardware fault — return unit for repair or replace servo inverter.
H05Internal Hardware FaultInternal board supply or power circuit fault detected.Internal power supply rail failed or control board failure.Internal hardware fault — replace the unit or contact Lenze service.
NMAXSpeed Limit ExceededActual motor speed exceeded maximum permissible limit.Unstable velocity loop control, runaway load, incorrect feedback resolution.Check motor speed feedback wiring, encoder resolution settings, and velocity loop gains.
P12Software Limit Switch ExceededPosition setpoint exceeded configured software end switch limits.Target position out of software limit range, axis unreferenced.Check axis position calibration, homing routine, and software limit parameters.
P13Following Error / Lag ErrorPosition tracking error exceeded maximum allowable tracking tolerance.Axis mechanically jammed, acceleration set too high, position loop gain low.Check mechanical axis freedom, load, lag error tolerance window, and position loop gain.
Sd2Resolver FaultResolver signal loss or invalid resolver feedback on X7 interface.Broken cable, loose X7 Sub-D connector, defective resolver sensor.Check resolver cable connections and shielding at X7; test resolver resistance.
Sd3Encoder Channel FaultIncremental encoder signal loss or channel failure on X8 interface.Encoder cable wire break, missing encoder supply voltage, signal noise.Check encoder cable and connector X8; check 5V/15V encoder power supply.
Sd6Absolute Encoder / SSI FaultSSI or absolute encoder communication failure.SSI encoder telegram error, wire break in clock/data lines.Check SSI cable shielding, wiring, and encoder power supply.
LP1Mains Phase FailureOne of the three incoming line power phases is missing.Blown mains input line fuse, loose main line terminal connection.Check input fuses and measure line voltage across L1, L2, L3 terminals.

Frequently Asked Questions

What is the cooling mechanism used by the Lenze EVS9326-KHV531 servo inverter?

The EVS9326-KHV531 features a cold-plate heat sink construction (KH version) designed to transfer heat directly to an external cooling panel or heat sink, saving control cabinet depth.

How are parameters transferred to a spare EVS9326-KHV531 drive?

Parameters stored in the non-volatile internal EEPROM can be transferred using Lenze Global Drive Control (GDC) software via a PC connection or saved and restored locally using the EMZ9371BC XT Keypad inserted in the front AIF slot.

What fieldbus communication options are supported by the EVS9326-KHV531?

The drive includes an integrated CAN System Bus via terminal X4. Additional fieldbus networks are supported by inserting plug-in AIF modules such as the EMF2133IB PROFIBUS-DP card, EMF2177IB System Bus Adapter, LECOM RS232/RS485 modules, or INTERBUS adapters.

What does a solid red TRIP / FAULT LED indicate on the drive front panel?

A solid red TRIP / FAULT LED indicates that the drive has tripped on a fault condition. Detailed error codes and trip records can be read from parameter C0168 using GDC software or the EMZ9371BC keypad.

What should I do if an EEPROM error (EEr, EEr1, EEr2) occurs?

EEr codes indicate internal memory corruption or EEPROM write/read hardware failures. Attempt to reload factory default parameters or restore a verified backup. If the error persists, an internal board failure is present and the drive requires replacement.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.