Lenze 00451419 EVF8245-E 11 kW Frequency Inverter
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze 00451419 EVF8245-E is an 11 kW frequency inverter from the Lenze 8200 series, engineered for precise 3-phase motor speed regulation in industrial environments. Designed to operate across a broad supply voltage range of 320 V AC to 528 V AC, this AC drive delivers a rated output current of 23.5 A with a peak output current capacity of 35.3 A, supporting 150% overload demands for up to 60 seconds. Operating across an output frequency range of 0 Hz to 480 Hz with adjustable switching frequencies from 2 kHz to 16 kHz, the unit features dual control capability, allowing configuration for standard V/f characteristic curve control or vector control for high-torque low-speed performance. It drives variable speed operations in conveyor transport systems, centrifugal pumps, industrial fans, and agitator machinery across material handling, packaging, water, and chemical processing facilities.
Integrating the EVF8245-E into an existing cabinet involves connecting fieldbus interfaces and transferring operational parameters. The drive architecture includes an open plug-in function slot designed to host communication adapters such as the EMF2102IB LECOM module, the EMF2171IB CANopen system bus module, or the EMF2133IB PROFIBUS-DP module. Placing a spare unit into service requires copying the four non-volatile parameter sets stored in internal EEPROM, which can be accomplished using the optional EMZ8201BB keypad module or Lenze Global Drive Control (GDC) PC software. Swapping the fieldbus module and loading saved parameters onto the spare unit ensures proper network addressing and matching motor profiles. ABC Industrial Parts can assist maintenance teams with technical guidance when transferring parameter profiles or preparing donor units for installation.
System status monitoring and troubleshooting on the EVF8245-E rely on integrated visual indicators and software diagnostic tools. Two front-panel LEDs provide immediate state indication: a green LED displays inverter operation readiness, while a red LED signals an active TRIP condition or fault state. Detailed error history and diagnostic codes—such as overcurrent events (OC1, OC2, OC3, OC5), DC bus overvoltage or undervoltage (OU, LU), and thermal overload warnings (OH, OH7)—are displayed via the EMZ8201BB keypad or monitored online using GDC software. Initial troubleshooting should confirm line voltage supply stability, check motor winding insulation, inspect cooling fan operation, and verify fieldbus module alignment. Unrecoverable memory errors, such as internal EEPROM faults (EER), indicate hardware failures that are not field-repairable, making unit exchange or repair through ABC Industrial Parts the standard route to restore operational production.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | 00451419 |
| Model/Type | EVF8245-E |
| Product Family | 8200 Series |
| Component Type | Frequency Inverter |
| Rated Power | 11 kW |
| Supply Voltage Range | 320 - 528 V AC |
| Supply Phase | 3-phase |
| Rated Output Current | 23.5 A |
| Maximum Output Current | 35.3 A (150% for 60s) |
| Output Frequency Range | 0 - 480 Hz |
| Switching Frequency | 8 kHz (Selectable 2 - 16 kHz) |
| Control Method | V/f characteristic or vector control |
Programming and Configuration
The Lenze EVF8245-E frequency inverter uses non-volatile EEPROM memory to store up to four distinct internal parameter sets. These parameter profiles enable flexible multi-mode machinery control without requiring external reprograming during production line changeovers.
Parameterization and drive tuning are executed using Lenze Global Drive Control (GDC) PC software or directly through the optional plug-in EMZ8201BB keypad module. During unit replacement, saved configuration files or keypad parameter clones can be downloaded directly into the replacement drive to match existing acceleration profiles, current limits, and operational parameters.
Communication and System Integration
Network integration for the 00451419 drive is supported via an open function module option slot. The modular interface design accepts various fieldbus cards to connect the inverter directly into plant control networks.
Supported communication cards include the EMF2102IB LECOM module (RS232/RS485), the EMF2171IB CANopen system bus module, and the EMF2133IB PROFIBUS-DP module. Installing these options enables continuous speed command transmission, remote control, and online drive diagnostics from a central PLC.
Diagnostics and Status Indication
Front-panel visual indicators provide immediate status monitoring for the EVF8245-E inverter. A green status LED indicates operational readiness and inverter state, while a red LED illuminates or flashes to indicate an active TRIP fault condition.
Comprehensive diagnostic logging and active operating values are accessible using the EMZ8201BB keypad display or via the online diagnostic monitor in Lenze Global Drive Control (GDC) PC software.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Green LED | Green - Solid / Flashing | Inverter state / Operation ready indication |
| Red LED | Red - Solid / Flashing | Fault condition / TRIP active indication |
Replacement and Spare Part Considerations
When swapping out a defective EVF8245-E frequency inverter, ensure that installed communication option cards—such as the EMF2102IB LECOM, EMF2171IB CANopen, or EMF2133IB PROFIBUS-DP module—are physically transferred to the replacement unit. The keypad module EMZ8201BB must also be reattached if keypad control or parameter cloning is utilized.
Because operational settings reside in non-volatile EEPROM memory across four distinct parameter sets, backup parameter files should be loaded into the donor unit via Global Drive Control (GDC) software or keypad copy functions before running the system. For complete machine redesigns or plant modernization projects, Lenze recommends migrating to the modern i550 cabinet frequency inverter series.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short circuit / Earth fault | Short circuit or ground fault detected during acceleration | Motor cable short circuit, ground fault in motor winding, acceleration time set too short | Check motor wiring and insulation, increase acceleration time setting |
| OC2 | Short circuit / Earth fault during deceleration | Short circuit or ground fault detected during deceleration | Motor cable short circuit, ground fault, deceleration time set too short | Check motor wiring and insulation, extend deceleration ramp time |
| OC3 | Short circuit / Earth fault during steady operation | Short circuit or ground fault detected during steady speed operation | Intermittent short circuit, motor overload, sudden shock load | Check motor insulation and mechanical load condition |
| OC5 | Inverter I2t overload | Inverter overload current limit exceeded over time threshold | Continuous current demand exceeds rated inverter output current | Reduce mechanical load, verify motor and inverter size match |
| OU | Overvoltage in DC bus | DC bus voltage exceeded upper threshold limit | Mains voltage transient or excessive generative energy during braking | Extend deceleration time or connect braking chopper/resistor |
| LU | Undervoltage in DC bus | DC bus voltage fell below minimum allowable voltage limit | Mains power supply drop, phase failure, or supply interruption | Check mains voltage supply levels and line supply fuses |
| OH | Heatsink overtemperature | Inverter heatsink temperature exceeds safety limit | Insufficient cooling airflow, dirty heatsink fins, excessive ambient temperature or fan fault | Clean heatsink, inspect enclosure cooling/ventilation, check cooling fan functionality |
| OH7 | Motor thermal overload | Motor PTC thermistor / thermal contact triggered | Motor overheating due to excessive load or inadequate cooling at low speeds | Allow motor to cool down, check motor load and cooling fan |
| EER | EEPROM memory fault | Internal parameter memory corruption or read/write error | Internal EEPROM failure or data corruption during save process | Reset to factory default settings; if error persists, internal hardware fault — replace the unit |
| CE0 | Communication fault | Communication interruption between inverter and plug-in module or controller | Disconnected fieldbus cable, module hardware fault, or timeout | Check communication module seats, wiring, shielding, and master connection |
Frequently Asked Questions
What software is required to configure the Lenze 00451419 EVF8245-E inverter?
Drive configuration, parameter cloning, and online monitoring can be performed using Lenze Global Drive Control (GDC) PC software or directly via the plug-in EMZ8201BB keypad module.
Which fieldbus modules are supported by the EVF8245-E option slot?
The open module slot supports the EMF2102IB LECOM module (RS232/RS485), the EMF2171IB CANopen system bus module, and the EMF2133IB PROFIBUS-DP module.
How are parameter settings transferred to a replacement unit?
Parameters stored across the four internal EEPROM memory sets can be uploaded and downloaded using Lenze Global Drive Control (GDC) software or cloned directly using the EMZ8201BB keypad module.
What do the front-panel status LEDs indicate on the drive?
The green LED displays operational readiness and inverter state, while the red LED signals an active TRIP fault condition.
How should an EER fault code be resolved on the EVF8245-E?
Fault code EER indicates an internal EEPROM parameter memory error. Attempt to reset the drive to factory default settings; if the error persists, an internal hardware failure has occurred requiring unit replacement or repair.
What is the recommended modern replacement path for the EVF8245-E?
For modernizations or new cabinet designs, Lenze recommends migrating to the i550 cabinet frequency inverter series.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.