Lenze 13015894 EVS9324-ES 9300 Servo Inverter Drive 5.5kW

New 
On request
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo | Series: 9300 Servo

The Lenze 13015894 (model EVS9324-ES) is a 5.5 kW panel-mounted AC servo inverter drive belonging to the Lenze 9300 Servo series. Designed for high-dynamic motion control applications, this unit operates on a three-phase supply voltage ranging from 320 to 528 V AC (nominal 400/480 V AC) with a rated input current of 12 A. The drive delivers a continuous output current of 13 A at an 8 kHz switching frequency, with a peak output current capability of 19.5 A for up to 60 seconds. Utilizing Field Oriented Control (FOC) algorithms across an output frequency range of 0 to 480 Hz, it provides precise positioning, speed, and torque control for synchronous and asynchronous AC servo motors in automated packaging, printing, material handling, and plastics machinery.

Physical integration features an onboard Sub-D connector for primary resolver feedback, incremental encoder feedback ports, an integrated Lenze CAN system bus interface, and a modular Automation Interface (AIF) slot for plug-in fieldbus modules such as the PROFIBUS-DP EMF2133IB or CANopen EMF2178IB. Commissioning or installing a replacement unit requires restoring the drive parameters to match the target machine's operating profile. The drive stores up to four complete parameter sets in internal non-volatile memory, which can be extracted and loaded using the plug-in Keypad XT (EMF2102IB) or Lenze Global Drive Control (GDC) software via a USB-to-CAN adapter (EMF2177IB). To ensure seamless line startup, ABC Industrial Parts can assist with extracting parameter profiles from existing drives or donor hardware.

System status and diagnostics are communicated via three front panel status LEDs—Red, Green, and Yellow—which indicate controller states, active trip conditions, warning limits, and specific fault group blinking codes. Detailed diagnostic monitoring and a fault history memory buffer can be accessed directly using Keypad XT or GDC software to inspect real-time metrics such as DC bus voltage, output current, motor speed, and heatsink temperature. While field-level faults like overvoltage (OU), undervoltage (LU), or overcurrent (OC1) can often be resolved by checking supply lines, braking resistors, or motor insulation, internal hardware errors such as EEPROM failure (EER), control board faults (H05), or power section errors (H10) are non-field-serviceable. In these instances, obtaining a fully tested replacement drive or unit repair through ABC Industrial Parts provides the fastest path to restoring operational productivity.

Technical Specifications

ManufacturerLenze
Part number13015894
Model / typeEVS9324-ES
Product family9300 Servo
Component typeServo Inverter Drive
Rated output power (400V)5.5 kW
Rated output power (480V)7.5 hp
Nominal supply voltage400 / 480 V AC
Supply voltage range320 - 528 V AC
Rated input current12 A
Continuous output current13 A
Maximum output current (60s)19.5 A
Output frequency range0 - 480 Hz
Switching frequency8 kHz
Control methodField Oriented Control (FOC)
Power dissipation220 W

Programming and Configuration

Parameter management and programming for the Lenze EVS9324-ES are conducted using Lenze Global Drive Control (GDC) software or the optional Keypad XT (EMF2102IB). Software connectivity is established through the Lenze CAN system bus using a USB-to-CAN Adapter (EMF2177IB). GDC allows technicians to configure motion profiles, adjust Field Oriented Control loop parameters, set dynamic limits, and monitor live drive telemetry.

The EVS9324-ES features internal non-volatile EEPROM memory capable of retaining up to four complete parameter sets without requiring battery backup. When replacing an operational unit, parameters must be cloned from the active drive to the replacement module to preserve motor settings, feedback calibration, network node identifiers, and I/O assignments. If parameter data becomes corrupted, fault code PR0 triggers, requiring a backup restore from GDC or reload of factory defaults.

Communication and System Integration

Network communication is natively supported via the built-in Lenze CAN system bus, which operates at transmission speeds up to 500 kbps over terminal block X4. The CAN interface facilitates high-speed peer-to-peer data exchange, axis synchronization, and master-slave velocity or torque commands across multi-axis production systems. Proper bus termination with 120-ohm resistors at physical line ends is required to prevent communication interruptions.

System integration flexibility is expanded through the onboard Automation Interface (AIF) slot, which accommodates plug-in communication modules. Supported option cards include the PROFIBUS-DP module EMF2133IB and CANopen module EMF2178IB, as well as INTERBUS options. The AIF module allows the servo drive to interface directly with higher-level PLCs and plant automation networks. Communication timeouts between the main control card and the AIF module trip fault code CE1, requiring verification of card seating and network cabling.

Diagnostics and Status Indication

Real-time status indication on the EVS9324-ES is provided by three diagnostic LEDs located on the front panel. The Green LED indicates operational readiness or controller enable state, flashing when inhibited and solid when running. The Yellow LED illuminates or flashes during warning conditions, such as current limit threshold activation. The Red LED flashes error group codes during trip events or remains continuously lit during severe drive faults.

Detailed diagnostic evaluation is performed via Keypad XT or GDC software, which provides access to an internal fault history memory buffer. Maintenance personnel can monitor real-time operating variables including DC bus voltage, output current, motor speed, and heatsink temperature.

Status LED Indicators

LEDColor/StatusMeaning
Red LEDRed - Solid / BlinkingDrive fault or TRIP active; blinking code indicates error group, steady illumination indicates critical fault.
Green LEDGreen - Solid / BlinkingBlinking indicates controller ready or inhibited; continuous indicates controller enabled and operating.
Yellow LEDYellow - Solid / BlinkingWarning indicator or special controller state such as current limit reached.

Replacement and Spare Part Considerations

When replacing an existing Lenze EVS9324-ES servo drive, match the complete part number (13015894) and model designation to ensure identical electrical ratings and control card compatibility. Verify that the incoming supply voltage matches the 320 to 528 V AC operating window and that the existing braking resistor and motor feedback connections match the Sub-D resolver input (X7) or encoder ports.

Replacement units are not plug-and-play and must be configured with the specific parameter set from the original drive before operation. Transfer parameter profiles using Keypad XT (EMF2102IB) or GDC software over a USB-to-CAN connection. Ensure that any installed AIF fieldbus option cards—such as PROFIBUS-DP (EMF2133IB) or CANopen (EMF2178IB)—are transferred to the spare unit and properly seated in the AIF slot, with network node addresses and termination resistors reconfigured as required.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short CircuitShort circuit or ground fault at the inverter output motor terminals.Short circuit in motor winding, damaged motor cable, or internal power transistor (IGBT) failure.Check motor wiring and insulation. Disconnect motor and check if drive powers up without OC1. If OC1 persists with motor disconnected, internal power module is damaged requiring hardware repair or replacement.
OC2Earth FaultGround short circuit on output phase lines.Motor winding grounded, cable shield grounded improperly, or excess capacitive ground leakage.Check motor cable insulation to ground using megohmmeter. Inspect motor terminal box.
OC5Ixt OverloadInverter output overcurrent / continuous overload threshold exceeded.Mechanical overload, motor sized too small, dynamic acceleration time too short.Reduce acceleration rates, check mechanical loading and motor sizing.
OUOvervoltage DC BusDC bus voltage exceeds maximum limit (> 770 V DC).Excessive regenerative energy during deceleration, mains supply voltage too high, or brake chopper/resistor not functioning or undersized.Increase deceleration time, check braking chopper resistor connection, measure line supply voltage.
LUUndervoltage DC BusDC bus voltage dropped below minimum operating limit (< 430 V DC).Mains supply line failure, blown line fuse, line phase loss, or power supply dip.Check incoming AC line supply voltages, check fuses and main contactor.
OHHeatsink OvertemperatureInverter heatsink temperature exceeded maximum threshold (> 85°C).Control cabinet cooling inadequate, heatsink clogged with dust, or internal fan failure.Clean heatsink cooling fins, verify cabinet ventilation and ambient temperature, replace internal cooling fan if stopped.
OH3Motor OvertemperatureMotor temperature sensor trip (PTC / thermal contact switch tripped).Motor thermal overload, cooling fan failure on motor, broken temperature sensor wire.Allow motor to cool, check motor loading, check PTC thermistor terminal connection.
OH4Inside Temperature OverlimitInternal temperature inside the drive enclosure exceeded limit (> 70°C).High ambient operating temperature or failure of internal enclosure air circulation.Improve cooling inside control cabinet.
OH7Motor Temp Sensor Wire BreakOpen circuit detected on motor thermal sensor terminals.Disconnected motor thermal monitoring cable or damaged sensor circuit.Check wiring to thermistor input terminals.
Sd7Resolver FaultResolver signal missing or corrupted.Resolver cable disconnected, defective resolver sensor, or severe EMI interference.Inspect resolver connection on plug X7, check cable shielding, test resolver coils for proper resistance.
CE0CANbus Communication FaultSystem bus (CAN) communication interrupt or bus-off event.CAN bus wiring disconnected, missing terminating resistors (120 Ohm), or incorrect baud rate setting.Check CAN wiring at X4 terminals, confirm bus termination resistors at line ends, verify CAN node IDs and baud rate.
CE1Automation Interface (AIF) FaultCommunication error between drive control card and plug-in fieldbus module in AIF slot.Fieldbus communication timeout or module seated improperly.Check fieldbus network connection and verify communication module seating in AIF slot.
EEREEPROM Memory FaultRead/write checksum failure in internal non-volatile EEPROM.Internal EEPROM memory chip corruption or hardware failure.Internal hardware fault. Reload parameter set from Keypad/GDC. If error persists, unit requires return for repair or replacement.
H05Internal Hardware ErrorInternal control board hardware fault detected during self-test.Control board component failure or corrupt internal microcode.Non-field-serviceable internal failure — return unit for factory repair or replacement.
H10Power Section Hardware ErrorFault in internal power section driving board or gate driver circuitry.Power card failure or gate drive power supply fault.Non-field-serviceable internal failure — unit must be serviced or replaced.
NMAXSpeed Limit ExceededMotor feedback speed exceeded absolute maximum safe speed parameter setting.Uncontrolled motor runaway, incorrect encoder/resolver setup, or inappropriate speed controller tuning.Check speed controller parameter settings and feedback device configuration.
PR0Parameter Data InvalidSelected parameter set corrupted or contains out-of-range values.Incomplete transfer of parameter set or power loss during parameter save.Restore parameters from backup file or reload default factory parameter configuration.

Frequently Asked Questions

What software and hardware tools are required to program the Lenze EVS9324-ES?

The drive is configured using Lenze Global Drive Control (GDC) software connected via a USB-to-CAN Adapter (EMF2177IB), or locally using the plug-in Keypad XT (EMF2102IB).

How are parameter settings transferred to a replacement EVS9324-ES drive?

Parameter profiles can be backed up from the active or donor drive using Keypad XT or GDC software and transferred directly to the non-volatile EEPROM memory of the replacement unit.

What do the front panel status LEDs indicate on the EVS9324-ES?

The Green LED indicates controller readiness and operation state, the Yellow LED indicates warning thresholds such as current limiting, and the Red LED indicates active TRIP faults or error group codes.

Which fieldbus interfaces are compatible with the EVS9324-ES?

In addition to the integrated Lenze CAN system bus, the drive supports plug-in AIF modules including PROFIBUS-DP (EMF2133IB), CANopen (EMF2178IB), and INTERBUS modules.

What causes fault code OC1 and how should it be cleared?

OC1 indicates an overcurrent or ground fault at the motor output terminals. Inspect motor insulation and cabling. Disconnecting the motor can help identify whether the fault resides in external wiring or the internal IGBT power module.

Can hardware fault codes like H05 or H10 be repaired on-site?

No. Codes H05 and H10 indicate non-field-serviceable internal control card or power section hardware failures, requiring full hardware repair or drive replacement.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.