Product Information

Product Family: 9300 Servo

The Lenze 13015966, model EVS9321-EPV004, is a 0.75 kW servo positioning controller within the Lenze 9300 Servo product family. Operating across a 3-phase AC supply voltage range of 320 V to 528 V AC with a 400 V AC nominal supply rating, this drive delivers a continuous rated output current of 2.5 A and a maximum output frequency of 480 Hz. Designed with integrated motion control positioning logic, the unit handles dynamic load cycles with a 150% peak current capacity of 3.75 A for up to 60 seconds. This positioning controller is deployed in applications such as multi-axis synchronization, pick-and-place material handling gantries, high-speed packaging machinery, and printing operations without requiring external motion hardware.

Connecting and installing the EVS9321-EPV004 involves physical interfaces for control signals, encoder feedback, and fieldbus communication. Dedicated connections include a Sub-D 9-pin resolver feedback port, a Sub-D 15-pin master encoder or frequency bus interface, four digital inputs, two digital outputs, two differential analog inputs (+/-10V), and two differential analog outputs (+/-10V). Fieldbus communication is expandable via an Automation Interface (AIF) slot that supports pluggable communication modules such as the EMF2133IB or EMF2131IB PROFIBUS-DP units. Commissioning a replacement unit requires restoring the parameter configuration, as the controller utilizes internal non-volatile EEPROM storage supporting up to four independent parameter sets. Parameters can be transferred using Lenze Global Drive Control (GDC) software, EASY Starter, or a pluggable EMZ9371BC XT keypad. ABC Industrial Parts can assist maintenance teams with parameter extraction and device preparation when installing spare drives.

Diagnostic conditions on the EVS9321-EPV004 are signaled via dedicated front-panel status LEDs and internal diagnostic logs. A solid red TRIP LED signals an active protective shutdown fault state, while the green Ready/Operating LED flashes when the drive is ready but inhibited, and turns solid green when the drive is enabled and operational. Detailed diagnostic status can be accessed via the keypad error history log, GDC online oscilloscope monitoring, or CAN system bus registers. Fault codes such as OC1 (short circuit), Sd2 (resolver failure), or OU (DC bus overvoltage) assist in troubleshooting field wiring, brake choppers, or motor insulation. Internal hardware errors such as H05 or unrecoverable memory faults like P12 indicate board-level failures that cannot be serviced in the field, making unit repair or a pre-tested replacement unit through ABC Industrial Parts the most practical solution to restore operation.

Technical Specifications

ManufacturerLenze
Part Number13015966
Model / TypeEVS9321-EPV004
Component TypeServo Positioning Controller
Product Family9300 Servo
Rated Power0.75 kW
Nominal Supply Voltage400 V AC
Supply Voltage Range320 - 528 V AC
Rated Output Current2.5 A
Peak Output Current3.75 A
Maximum Output Frequency480 Hz
System BusCAN system bus (500 kbit/s)
Feedback InterfaceSub-D 9-pin Resolver
Master Encoder InterfaceSub-D 15-pin Incremental / Frequency Bus
Digital Inputs / Outputs4 Inputs / 2 Outputs
Analog Inputs / Outputs2 Inputs (+/-10V) / 2 Outputs (+/-10V)

Programming and Configuration

The Lenze EVS9321-EPV004 features onboard positioning logic and integrated non-volatile memory capable of storing up to four independent parameter sets. Programming and commissioning are executed using Lenze Global Drive Control (GDC) engineering software or EASY Starter tools. These software packages facilitate drive parameterization, real-time signal monitoring, and complete backup file generation for fast unit replacement.

For field configuration without a PC, the unit supports the pluggable Lenze EMZ9371BC XT control keypad. The keypad connects directly to the drive, allowing technicians to modify operational parameters, review error history logs, and copy parameter profiles between compatible 9300 Servo drives. Restoring parameter sets to a new drive ensures that positioning control profiles, acceleration ramps, and I/O assignments match the machine specifications.

Communication and System Integration

System integration with the EVS9321-EPV004 is centered around an onboard CAN system bus interface operating at speeds up to 500 kbit/s via a Sub-D connection. This integrated CAN bus enables multi-axis synchronization, electronic shaft positioning, and rapid data exchange between multiple Lenze servo controllers. Correct network layout requires 120-Ohm terminating resistors at both physical ends of the CAN bus line.

Higher-level network integration is achieved through the built-in Automation Interface (AIF) slot. This expansion port accepts modular communication hardware, including the EMF2133IB and EMF2131IB PROFIBUS-DP modules, as well as INTERBUS or serial interface units. In addition, a Sub-D 15-pin master encoder interface allows master-slave drive coupling and frequency bus integration for complex multi-axis motion sequences.

Diagnostics and Status Indication

The Lenze EVS9321-EPV004 provides comprehensive system diagnostic capabilities using hardware LEDs, keypad status logs, and software monitoring tools. Front-panel LED indicators display real-time operational status, while software tools like Global Drive Control offer online diagnostic oscilloscopes and register readout over the system bus.

Status LED Indicators

LEDColor/StatusMeaning
Red LED (TRIP)Red - SolidActive fault/trip state. Drive disabled due to protective shutdown.
Green LED (Ready / Operating)Green - Blinking / SolidBlinking green indicates drive ready / inhibited; solid green indicates drive operational and enabled.

Replacement and Spare Part Considerations

When replacing a failed Lenze EVS9321-EPV004 servo positioning drive, verify that the replacement unit matches the part number 13015966 and model designation EVS9321-EPV004. Because the drive relies on application-specific positioning parameters and I/O configurations stored in non-volatile memory, installing an unconfigured unit without restoring the parameter set will prevent normal machine operation.

Before commissioning a replacement unit, backup files created via Global Drive Control (GDC) or EASY Starter must be downloaded to the drive, or parameter data must be transferred directly using an EMZ9371BC XT keypad. Additionally, any option module installed in the Automation Interface (AIF) slot, such as a PROFIBUS-DP module, must be transferred to the replacement controller and checked for firm seating and pin alignment.

Physical mounting and cable connections should be verified prior to powering up. Ensure resolver wiring connected to terminal X7 and encoder connections at X8/X9 are secure, and check that terminating resistors are properly placed if the onboard CAN bus is used. If internal power module or memory failure codes such as H05 or P12 occur, internal components cannot be serviced on-site, requiring drive repair or an exchange unit.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short CircuitShort circuit or ground fault at motor output power terminalsShort circuit in motor cable, motor winding insulation failure, or power stage short-circuitCheck motor wiring and insulation; if fault persists with motor disconnected, internal hardware fault — return unit for repair
OC5Ixt OverloadDrive overload monitor activated (i2t thermal limit exceeded)Continuous current demand exceeding continuous rating, mechanical jam, or undersized driveCheck mechanical load for blockage, verify acceleration profiles, check motor dimensioning
OHHeatsink OvertemperatureHeatsink temperature exceeded permissible maximum limitInsufficient cooling, clogged heatsink, ambient temperature too high, or cooling fan failureClean cooling fins, ensure proper cabinet ventilation, check external fan operation
OH4Motor OvertemperatureThermal switch or PTC sensor connected to motor temperature monitoring terminal trippedMotor overheating due to excessive load, failure of motor cooling, or sensor wiring open circuitAllow motor to cool down, check motor load and forced ventilation, verify sensor wiring at terminal X10
OUOvervoltage DC BusIntermediate DC circuit voltage exceeded maximum thresholdExcessive regenerative energy during braking, insufficient braking resistor power, or line supply voltage spikeExtend deceleration ramps, check brake chopper circuit and external brake resistor connection
LUUndervoltage DC BusIntermediate DC circuit voltage dropped below minimum thresholdMains supply voltage drop, phase loss, or main contactor open while operatingCheck mains voltage input, verify line fuses and input wiring
P12EEPROM FaultParameter data corruption or fault reading internal EEPROM memoryPower interruption during parameter write or EEPROM memory failureReload factory default parameters and re-commission; if error persists, internal board fault — contact service / replace unit
H05Internal Hardware ErrorPower section or internal control hardware defect detected during power-on self testDefective internal power module or control board hardware failureInternal hardware fault — return unit for repair or replace device
Sd2Resolver FaultFeedback fault from motor resolver connected to X7 interfaceResolver cable disconnected, broken wire, bad connection, or resolver failureCheck resolver feedback cable shielding, wiring connections, and motor resolver impedance
Sd3Encoder Signal FaultMaster encoder / frequency bus track signal failure at X8/X9Encoder wire broken, track missing, or noise interferenceInspect encoder cable, shielding, and connection at X8/X9 terminals
CE0CAN Communication ErrorBus off state or communication timeout on integrated CAN system busCAN bus line interruption, missing terminating resistors (120 Ohm), or incorrect baud rate settingCheck CAN cabling, verify termination resistors at both bus ends, check node address and baud rate settings
AIF-EAIF FaultCommunication failure between control board and optional module in AIF slotLoose module, defective fieldbus module, or configuration mismatchRe-seat communication module in slot AIF, inspect module connector pins, replace module if failure persists

Frequently Asked Questions

What software is used to program and parameterize the Lenze EVS9321-EPV004?

The drive is configured using Lenze Global Drive Control (GDC) software or Lenze EASY Starter. Alternatively, basic parameter adjustments and parameter transfers can be performed using the pluggable EMZ9371BC XT keypad.

How are parameter settings transferred to a replacement EVS9321-EPV004 drive?

Parameter settings can be transferred by uploading a backup file via GDC software or by saving parameter sets onto an EMZ9371BC XT control keypad from the original drive and downloading them to the replacement unit.

What fieldbus options are supported by the Lenze EVS9321-EPV004?

The drive includes an onboard CAN system bus (up to 500 kbit/s) and features an Automation Interface (AIF) slot that accepts optional fieldbus modules, including the EMF2133IB and EMF2131IB PROFIBUS-DP modules or INTERBUS interfaces.

What do the red and green status LEDs on the front panel indicate?

A solid red TRIP LED indicates an active fault state and protective drive shutdown. A blinking green LED indicates the drive is ready but inhibited, while a solid green LED indicates the drive is operational and enabled.

How should I respond to internal hardware fault codes like H05 or P12?

Fault code H05 indicates an internal hardware defect in the control or power board, while P12 indicates EEPROM parameter memory corruption. If re-loading default parameters does not clear P12, both errors represent internal faults that require returning the unit for repair or replacing the device.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.