Lenze EVS9324-EP 13180717 9300 Servo Drive

New 
On request
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo

The Lenze EVS9324-EP (part number 13180717) is an industrial position control servo drive from the Lenze 9300 Servo series. Engineered to execute precise motion control tasks without requiring external PLC positioning hardware, this 3.0 kW unit supplies a continuous output current of 9.5 A with a maximum peak output capability of 14.3 A for 60 seconds. Operating on a 3-phase mains voltage between 320 V AC and 528 V AC at 45 Hz to 65 Hz (400/480 V AC nominal), the drive features integrated -EP software functions capable of handling relative and absolute positioning, S-curve profile generation, torque and velocity management, and automated homing routines.

Physical integration is supported through Sub-D 9-pin connectors dedicated to resolver feedback (X7), encoder feedback (X8), and frequency simulator outputs (X9), along with an onboard CAN system bus interface (X4) operating at speeds up to 500 kbit/s for inter-drive synchronization. An internal expansion slot allows connection of fieldbus modules such as PROFIBUS-DP (EMF2133IB/EMF2131IB), DeviceNet (EMF2175IB), or INTERBUS (EMF2102IB). Commissioning a spare or replacement unit requires downloading or transferring parameter sets via Lenze Global Drive Control (GDC) software or an EMZ9371BC keypad operating module. Up to four parameter configurations can be stored in internal non-volatile EEPROM, making correct parameter migration from ABC Industrial Parts key to establishing identical machine behavior.

System diagnostic states are indicated on the unit via status LEDs and can be queried via terminal X5, the keypad interface, or the CAN bus. A green LED indicates operational readiness or drive disablement, while a red LED signals active warnings or trip conditions. An internal fault buffer stores the last eight TRIP fault events complete with timestamps, assisting in the isolation of system trips like heatsink overtemperature (OH), DC bus overvoltage (OU), or resolver line loss (Sd2). When unrecoverable internal failures such as code H05 occur on control or driver boards, field servicing is not possible, making a pre-tested replacement unit or professional repair service from ABC Industrial Parts the most efficient path back to operational capability.

Technical Specifications

ManufacturerLenze
Part number13180717
Model / TypeEVS9324-EP
Product family9300 Servo
Component typeServo Drive
Rated power3.0 kW
Continuous output current9.5 A
Maximum output current14.3 A (for 60 s)
Supply voltage range320 - 528 V AC
Nominal supply voltage400 / 480 V AC
Supply frequency45 - 65 Hz
Rated mains current9 A
Power loss160 W
Switching frequency8 kHz
Digital inputs8
Digital outputs4
Analog inputs2
Analog outputs2
System bus speedUp to 500 kbit/s

Programming and Configuration

The Lenze 9300 Position Control (-EP) variant embeds motion profiles, S-curve acceleration ramps, and homing commands directly into the drive firmware. Engineering and commissioning are performed using Lenze Global Drive Control (GDC) software connected via a PC adapter (such as EMF2171IB or EMF2177IB) or locally using the detachable EMZ9371BC keypad operating module.

Internal non-volatile EEPROM memory stores up to four complete parameter sets. This feature allows plants to maintain multiple production recipes or operating configurations locally on the drive. When commissioning a replacement drive, user parameters, motor feedback calibration, and motion program parameters must be transferred from a backup file or extracted from the original unit to retain proper positioning functionality.

Communication and System Integration

Network connectivity is anchored by an onboard CAN system bus interface at terminal X4. Supporting transmission speeds up to 500 kbit/s, this interface allows high-speed inter-drive communication and axis synchronization across multi-axis positioning architectures, packaging machinery, and rotary index tables.

For integration into broader industrial control networks, an automation slot accommodates optional fieldbus communication modules, including PROFIBUS-DP (EMF2133IB / EMF2131IB), DeviceNet (EMF2175IB), or INTERBUS (EMF2102IB). Motor feedback and pulse signals are connected via 9-pin Sub-D connectors: terminal X7 for resolver input, terminal X8 for incremental encoder input, and terminal X9 for frequency simulator output.

Diagnostics and Status Indication

The EVS9324-EP incorporates continuous monitoring of internal power stages, temperatures, feedback connections, and bus communications. Diagnostics are accessed locally via two front LEDs, through the EMZ9371BC keypad, over terminal X5 status channels, or via GDC software oscilloscope and status windows.

An onboard diagnostic memory buffer records the last eight TRIP fault events with associated timestamps. This buffer allows maintenance teams to review fault history and identify root causes such as line voltage drops, motor thermal overloads, or position feedback noise.

Status LED Indicators

LEDColor/StatusMeaning
Green LED (Ready / Operation)Green - Solid / BlinkingON = Inverter ready / normal operating state. Blinking = Drive disabled or operating in restricted mode.
Red LED (Fault / Error)Red - Solid / FlashingON or flashing = Active trip or warning present. Continuous red with drive lockout indicates active trip condition.

Replacement and Spare Part Considerations

When selecting a replacement for an EVS9324-EP drive, matching both the 3.0 kW power section and the specific -EP suffix is required. Standard non-EP variants of the 9300 series do not contain the embedded position control firmware, which will prevent the replacement unit from performing positioning tasks.

Before replacing an existing unit, parameter sets saved in the drive's EEPROM should be uploaded via Global Drive Control (GDC) software or copied using the EMZ9371BC keypad. Any communication modules present in the automation slot (such as PROFIBUS EMF2133IB) must be transferred to the spare unit, confirming that DIP switch addresses and line termination match the original setup.

If the existing drive registers unserviceable hardware faults like code H05 or internal short circuits under code OC1 with the motor disconnected, internal board-level servicing cannot be performed in the field. Installing a fully tested replacement drive or sending the unit for bench repair provides the fastest route to restoring production lines.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OHHeatsink temperature too highHeatsink temperature exceeded upper operating limit (>90°C).Insufficient cooling airflow, cabinet ventilation failure, fan defective, extreme ambient temperature or prolonged drive overload.Check cabinet ventilation and cooling fans, clean heatsink cooling fins, reduce load or duty cycle.
OH3Motor thermal sensor tripMotor temperature sensor (PTC / KTY) reported motor overtemperature.Motor thermal overload, blocked motor cooling, improper motor sizing or sensor wiring breakdown.Allow motor to cool down, check motor load, verify PTC/KTY sensor connections at control terminals.
OUDC bus overvoltageDC bus voltage exceeded maximum allowable threshold (approx. 770 V DC).Excessive braking energy fed back from motor during deceleration, deceleration ramp time set too short, braking chopper or braking resistor disconnected or defective.Extend deceleration time, connect external braking resistor, check braking chopper transistor and resistor resistance.
LUDC bus undervoltageDC bus voltage fell below minimum allowable threshold (approx. 430 V DC).Mains supply voltage drop, phase loss, blown supply fuse, instability in AC power line.Check mains voltage across all 3 supply phases, inspect main contactor and power line fuses.
OC1Overcurrent / Short circuitPeak output current exceeded trip limit immediately upon pulse enable.Short circuit in motor windings or motor power cable, ground fault, defective motor insulation, or internal power transistor short circuit.Disconnect motor cables and measure winding and phase-to-ground insulation resistance. If fault persists with motor cable disconnected, internal hardware fault — replace unit or return for repair.
OC2Overcurrent during accelerationOutput current exceeded acceleration threshold during speed ramp-up.Acceleration time set too short, excessive mechanical load inertia, incorrect motor parameter configuration.Increase acceleration time, check motor data and current limit parameters.
OC5Inverter I x t overloadThermal load accumulator (I x t) reached maximum limit due to continuous overcurrent.Drive operated above rated continuous current for an extended period.Reduce mechanical load, optimize duty cycle, verify servo drive sizing.
CE0System Bus (CAN) communication faultCommunication failure or time-out detected on System Bus (CAN).Interrupted CAN bus line, missing termination resistor, bad baud rate setting or excessive electrical noise.Verify CAN cable connection, bus termination (120 Ohm), shield grounding, and node address settings.
EEREEPROM data errorChecksum fault detected during read/write access to non-volatile parameter memory.Power interrupted during parameter saving, defective EEPROM chip.Reload factory default parameters and write to EEPROM. If error reoccurs, internal hardware fault — return unit for repair.
H05Internal hardware failurePower section or control card hardware fault detected during self-test routines.Component failure on internal control board or gate driver board.Internal hardware fault — field repair not possible. Return unit for repair or replace drive.
NMAXSpeed limit exceededActual motor velocity exceeded maximum configured speed limit threshold.Unstable velocity loop tuning, incorrect feedback scaling, runaway load condition.Check feedback encoder/resolver connections and speed controller gain settings.
Sd2Resolver signal faultResolver signal loss or track error detected at terminal X7.Broken or disconnected resolver cable, damaged connector pins at X7, bad cable shielding.Check resolver feedback cable wiring, shielding integrity, and connector tight fit at X7.

Frequently Asked Questions

What are the power ratings and supply requirements for the Lenze EVS9324-EP?

The Lenze EVS9324-EP (part number 13180717) delivers 3.0 kW output power with a continuous output current of 9.5 A and a 14.3 A peak current limit (for 60 seconds). It operates on a 3-phase supply of 320 V AC to 528 V AC at 45 Hz to 65 Hz (400/480 V AC nominal).

How are parameter settings transferred to a replacement EVS9324-EP drive?

Drive configurations are transferred using Lenze Global Drive Control (GDC) software connected via a PC adapter (EMF2171IB or EMF2177IB) or by using the EMZ9371BC keypad operating module. Up to four parameter sets stored in non-volatile EEPROM can be saved and reloaded onto the spare drive.

Can a standard Lenze 9300 drive replace an EVS9324-EP?

No. The -EP suffix denotes integrated position control software required for relative/absolute positioning, S-curve profiles, and homing algorithms. A standard 9300 drive lacks these embedded positioning routines and cannot execute the motion program.

What does fault code H05 mean on the Lenze EVS9324-EP?

Fault code H05 indicates an internal hardware failure on either the control board or the power section gate driver board detected during self-tests. This fault cannot be repaired in the field and requires sending the unit for repair or replacing the drive.

Which fieldbus communication modules fit into the expansion slot?

The automation slot on the EVS9324-EP supports optional fieldbus interface modules, including PROFIBUS-DP (EMF2133IB / EMF2131IB), DeviceNet (EMF2175IB), and INTERBUS (EMF2102IB), alongside the built-in CAN system bus interface.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.