Lenze 13252010 EVS9328-ES 9300 Series 22 kW Servo Drive
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze 13252010 EVS9328-ES is a 22 kW AC servo drive from the 9300 Servo Drives family, engineered for precise closed-loop speed, torque, and position control. Operating from a three-phase supply voltage ranging from 320 to 528 V AC at 45 to 65 Hz, the unit provides a continuous output current of 47 A at 400 V AC with a maximum output frequency of 480 Hz. To handle dynamic loads during acceleration, the inverter features a 150% overload capacity that delivers up to 70.5 A for up to 60 seconds. Designed for vertical panel mounting inside IP20 control cabinets, the drive incorporates dedicated resolver feedback processing to support AC brushless servo motors in multi-axis automation lines.
Connecting the drive into an existing control system involves both physical I/O terminals and dedicated communication interfaces. The EVS9328-ES features four digital inputs, two digital outputs, two analog inputs, two analog outputs, and a simulated encoder frequency output used for electronic gearing and line-shafting applications. System-level integration is supported via an onboard CAN system bus interface and an expansion slot (Slot A) compatible with modular fieldbus cards, including PROFIBUS-DP (EMF2133IB), CANopen (EMF2175IB), Interbus (EMF2102IBC), and LECOM RS-232/RS-485 (EMF2102IBV). Putting a replacement drive into service requires parameter alignment, as up to four switchable parameter sets are stored in the internal EEPROM. Transferring parameter data requires either the optional Keypad XT (EMF2102IB) or Lenze Global Drive Control (GDC) software version 4.0 or higher. Technical support from ABC Industrial Parts can assist in verifying setup parameters and recovering stored configurations from original units.
Diagnostic conditions are indicated directly through three status LEDs on the unit faceplate. A solid green RUN LED confirms normal operation with the inverter output stage enabled, a solid yellow WARN LED signals that a warning threshold such as an overload limit has been reached while keeping the output active, and a solid red TRIP LED indicates an active drive fault that disables the output stage. Detailed diagnostic data can be accessed via parameter C0168 (history buffer), status word C0150, or through textual error messages on the Keypad XT and GDC software oscilloscope logs. When troubleshooting fault conditions, initial checks should focus on mains supply stability, resolver cabling at terminal X3, motor winding continuity, and fieldbus module seating in Slot A. Internal errors like EEPROM corruptions or hardware self-test failures represent board-level defects that cannot be serviced in the field, making unit replacement or repair through ABC Industrial Parts the most direct path to restoring machine production.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | 13252010 |
| Model / Type | EVS9328-ES |
| Product Family | 9300 Servo Drives |
| Rated Power | 22 kW |
| Supply Voltage Range | 320 - 528 V AC |
| Continuous Output Current | 47 A |
| Peak Output Current | 70.5 A |
| Output Voltage | 400 V AC |
| Maximum Output Frequency | 480 Hz |
| Default Switching Frequency | 8 kHz |
| Protection Rating | IP20 |
| Mounting Type | Vertical Panel Mounting |
Programming and Configuration
Parameterization of the Lenze 13252010 EVS9328-ES servo drive is managed through Lenze Global Drive Control (GDC) PC software version 4.0 or higher, or using the pluggable Keypad XT (EMF2102IB) module. The internal EEPROM memory maintains up to four independent parameter sets, allowing operators to switch between different machine operating profiles or motor configurations.
Commissioning a replacement inverter requires uploading the existing parameter configuration from the original unit or backup file. Using GDC software or copying parameters via the Keypad XT ensures that motor data, switching frequencies (defaulting at 8 kHz), velocity loops, and I/O assignments match system requirements. Direct parameter extraction from non-responsive boards can preserve operational settings prior to swapping hardware.
Communication and System Integration
The EVS9328-ES incorporates an integrated CAN-based system bus interface designed for multi-axis drive synchronization, master-slave operations, and direct inter-drive communication without dedicated PLC hardware. For integration into broader industrial networks, the unit contains a dedicated modular card slot (Slot A).
Option modules compatible with Slot A include PROFIBUS-DP (EMF2133IB), CANopen (EMF2175IB), Interbus (EMF2102IBC), and LECOM RS-232/RS-485 (EMF2102IBV). Additional control hardware interfaces include four digital inputs, two digital outputs, two analog inputs, two analog outputs, and a simulated encoder output for precise electronic gearbox configuration.
Diagnostics and Status Indication
Visual diagnostic feedback on the EVS9328-ES is provided through three front-panel LEDs. The green RUN LED illuminates when power is applied and the output stage is enabled. The yellow WARN LED alerts technicians to impending fault conditions, such as current limit or thermal warning thresholds, while allowing continued operation. The red TRIP LED indicates a critical fault that immediately disables drive output.
Comprehensive diagnostic evaluation is supported through system parameter C0168, which logs historic fault codes, and parameter C0150, which provides real-time status word feedback over CANbus or fieldbus networks. Advanced diagnostics, including real-time signal logging and trend analysis, are available via the oscilloscope function in Global Drive Control software.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Red LED (TRIP) | Red - Solid | Indicates active drive fault/trip condition. Output stage is disabled. |
| Green LED (RUN) | Green - Solid | Indicates drive is powered and operating normally; output stage enabled. |
| Yellow LED (WARN) | Yellow - Solid | Indicates drive warning limit reached (e.g. current limit, Ixt warning). Output stage remains active. |
Replacement and Spare Part Considerations
When replacing an existing Lenze EVS9328-ES (part number 13252010), verify that the mechanical mounting space and IP20 vertical enclosure dimensions match the control cabinet layout. The drive requires a 320 to 528 V AC three-phase supply and supplies 47 A continuous output current to 400 V AC servo motors.
Before powering up a replacement drive, transfer any existing fieldbus communication modules from Slot A (such as PROFIBUS-DP or CANopen) to the spare unit. Ensure that parameter sets are fully restored using a Keypad XT or GDC software, confirming that CANbus node addresses, terminal I/O assignments, and resolver settings match the machine's control program.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short Circuit / Overcurrent | Short circuit on output terminals or excessive earth fault current detected. | Short circuit in motor winding or cable; ground fault; acceleration ramp too steep. | Check motor cable and motor insulation for short circuit or ground fault; increase acceleration time. |
| OC5 | Overcurrent during Acceleration | Output current exceeded dynamic limit during acceleration phase. | Acceleration ramp too short; load blocked or excessive inertia; incorrect motor parameters. | Extend acceleration ramp time; check mechanical system for jams; verify motor parameters. |
| OU | DC Bus Overvoltage | DC bus voltage exceeded upper limit threshold (approx. 770 V DC). | Excessive regenerative energy during deceleration; deceleration ramp too short; brake chopper or brake resistor failed/missing. | Extend deceleration time; check external brake resistor connection and resistor unit functionality. |
| LU | DC Bus Undervoltage | DC bus voltage dropped below minimum operating threshold. | Mains supply power outage, blown line fuse, or phase loss. | Check main input power lines, fuses, and contactors. |
| OH | Heatsink Overtemperature | Drive heatsink temperature exceeded maximum allowed limit. | Insufficient cooling airflow, dirty heatsink fins, internal fan failure, or high ambient temperature. | Clean heatsink, verify fan operation, and ensure panel ambient temperature is within specifications. |
| OH4 | Motor Overtemperature | Motor temperature sensor (PTC or thermal contact) triggered high temperature alert. | Motor thermal overload; insufficient motor cooling fan; thermal sensor wire disconnected. | Allow motor to cool; inspect motor load and mechanical binding; check thermal sensor wiring. |
| OH7 | Motor Sensor Wire Break | Open circuit detected on motor thermal monitoring input. | Disconnected thermal sensor cable or damaged sensor circuit. | Check wiring between drive terminals and motor thermal contact. |
| r03 | Resolver Fault | Loss or corruption of resolver feedback signal. | Defective resolver cable, missing shield connection, or faulty resolver in motor. | Check feedback cable, shield grounding, connector insertion on X3, and motor resolver. |
| EEr | EEPROM Memory Error | Internal non-volatile EEPROM read/write failure or parameter data corruption. | Hardware component failure on internal controller board; interrupted parameter write cycle. | Internal hardware fault — reload factory default settings; if fault persists, return unit for repair or replace drive. |
| H05 | Internal Hardware Fault | Internal hardware diagnostic failure during power-up or self-test. | Board level electronic component defect. | Internal hardware fault — non-field-serviceable; return unit to Lenze service center or replace unit. |
| CE0 | Communication Error (System Bus) | Communication interruption detected on integrated System Bus (CAN). | Bus cable broken, improper termination resistors, or master offline. | Check CAN wiring, baud rate setting, and 120 ohm terminating resistors. |
| CE1 | Communication Error (Slot A) | Communication failure between inverter CPU and fieldbus module in Slot A. | Fieldbus communication timeout or module seated incorrectly. | Check fieldbus module seating in Slot A and external fieldbus wiring/master. |
| LP1 | Motor Phase Failure | Missing output phase detected on motor supply terminal (U, V, W). | Disconnected motor cable lead, loose contactor, or unbalanced winding impedance. | Inspect output wiring, motor contactor, and measure motor winding resistance. |
| P12 | Current Transducer Fault | Offset fault detected in internal output current measurement circuit. | Defective internal current sensor or hardware measuring circuit failure. | Internal hardware fault — inspect unit or return to service facility for repair. |
Frequently Asked Questions
What software is required to configure the Lenze 13252010 EVS9328-ES?
The drive is configured using Lenze Global Drive Control (GDC) software version 4.0 or higher. Alternatively, basic parameter adjustments and parameter transfers can be performed using the optional Keypad XT (EMF2102IB) module.
Can parameter sets be transferred directly between drives without a PC?
Yes, parameter sets stored in the internal EEPROM can be copied directly using the optional Keypad XT module (EMF2102IB) and loaded into a replacement drive.
What fieldbus options are supported by the EVS9328-ES?
The drive features Slot A, which supports option cards including PROFIBUS-DP (EMF2133IB), CANopen (EMF2175IB), Interbus (EMF2102IBC), and LECOM RS-232/RS-485 (EMF2102IBV). It also includes an integrated CAN-based system bus.
What does a solid red TRIP LED indicate on the front panel?
A solid red TRIP LED indicates an active drive fault or trip condition. When this occurs, the inverter output stage is automatically disabled to protect the system.
What initial checks should be performed if fault code r03 appears?
Fault code r03 indicates a resolver feedback error. Check the feedback cable connected to terminal X3, verify shield grounding, inspect connector seating, and test the motor resolver windings.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.