ESA Automation EW107ND4SP000FR EW100 Esaware 7-Inch HMI Panel

New 
On request
Refurbished   
On request
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: Esaware | Series: EW100

The ESA Automation EW107ND4SP000FR is a 7-inch widescreen operator interface belonging to the Esaware EW100 family and EW107 series. Built around an ARM Cortex-A9 processor with 1 GB of DDR3 RAM and 4 GB of eMMC flash storage, this touchscreen HMI panel provides processing capacity for machine control, visualization, and alarm logging. The unit features an 800x480 WVGA TFT LCD display supporting up to 16.7 million colors, paired with a heavy-duty 4-wire analog resistive touchscreen suitable for gloved operation. Operating on a nominal 24 V DC power supply with an allowable input range of 18 to 32 V DC, it serves as a central interface across packaging, food and beverage, water treatment, and automated OEM equipment.

Physical connectivity on the EW107ND4SP000FR includes two independent 10/100 Mbit/s RJ45 Ethernet ports, a DB9 male serial interface supporting configurable RS232, RS485, and RS422 communication, two USB-A 2.0 Host ports, one USB Micro-B OTG port, and a MicroSD card slot supporting SDHC cards. Commissioning a replacement unit requires restoring the visual application project created in the ESA Crew Programming Suite. Project files, runtime configurations, and system backups can be loaded over the network connection or restored directly using a FAT32-formatted USB flash drive or MicroSD card. When swapping an operational unit, matching network parameters and protocol settings ensures proper communication with attached field devices and controllers, with ABC Industrial Parts providing tested replacement hardware to maintain machine availability.

System diagnostic information is available both through hardware indicators and built-in software tools. On-board status LEDs provide quick feedback regarding main board power state, runtime condition, and Ethernet port network activity. For deeper status evaluation, operators can access the ESA Crew system menu, on-screen hardware self-tests, and an integrated web-based diagnostic server for remote network inspection. Basic field troubleshooting involves verifying the 24 V DC power input, checking network and serial cabling, and confirming IP addresses or node numbers. When internal hardware failures prevent normal display or boot sequences, replacing the unit or sourcing a tested exchange panel through ABC Industrial Parts provides a straightforward path back to production.

Technical Specifications

ManufacturerESA Automation
Part NumberEW107ND4SP000FR
Model / TypeEW100 (EW107)
Product FamilyEsaware
Component TypeHuman Machine Interface (HMI)
Display Size7 inches
Display TypeWidescreen TFT LCD (16.7M colors)
Display Resolution800x480 pixels (WVGA)
Touchscreen Technology4-wire Analog Resistive
Supply Voltage (Nominal)24 V DC
Supply Voltage Range18 - 32 V DC
ProcessorARM Cortex-A9
RAM Memory1 GB DDR3
Flash Memory4 GB eMMC
Ethernet Ports2x RJ45 (10/100 Mbit/s, independent)
Serial Interface1x DE-9 Male (RS232/RS485/RS422 configurable)
USB Ports2x USB-A Host 2.0, 1x USB Micro-B OTG
Storage ExpansionMicroSD Card Slot (SDHC)

Programming and Configuration

Project development and configuration for the ESA Automation EW107ND4SP000FR are managed via the ESA Crew Programming Suite. The Linux-based Crew runtime engine running on the HMI processes screen graphics, alarm tables, data logging parameters, and driver communications. Projects engineered in the Crew environment are transferred to the panel's 4 GB eMMC flash storage via direct Ethernet download or localized media transfer.

For fast deployment and field maintenance, the panel supports direct project backups and restores using standard FAT32-formatted USB flash drives or MicroSDHC storage cards. This capability enables operators to update operational runtime software or extract system settings on-site without opening engineering software on a separate laptop.

Communication and System Integration

The EW107ND4SP000FR incorporates dual independent 10/100 Mbit/s RJ45 Ethernet ports, allowing network isolation between plant IT/visualization networks and dedicated fieldbus communication loops. This dual-port arrangement helps maintain secure control communications while presenting machine data to higher-level industrial networks.

In addition to Ethernet connectivity, the HMI panel includes a configurable DE-9 male serial port supporting RS232, RS485, and RS422 electrical standards. Integrated protocol drivers allow simultaneous multi-vendor PLC communication over Modbus TCP, Modbus RTU, and EtherNet/IP, with optional expansion support for PROFINET or CANopen field networks.

Diagnostics and Status Indication

The EW107ND4SP000FR provides visual hardware diagnostics alongside built-in software logging utilities. Integrated LEDs offer real-time status monitoring for main power state, system runtime condition, and active link or traffic on the RJ45 Ethernet ports.

Detailed diagnostic information can be reviewed using the ESA Crew system menu directly on the touch screen, which includes a hardware self-test routine and static IP network configuration options. Remote diagnostic assessment is supported through an integrated web-based diagnostic server and on-screen system log viewers.

Status LED Indicators

LEDColor/StatusMeaning
PWR / RUNSolid / FlashingIndicates board power state and operational status
COM / NETActivity dependentIndicates Ethernet link status and communication activity on RJ45 ports

Replacement and Spare Part Considerations

When replacing an existing EW107ND4SP000FR HMI panel, ensure the replacement unit is powered with a clean 24 V DC supply operating within the 18 to 32 V DC tolerance range. The physical footprint fits panel cutouts designed for standard 7-inch widescreen Esaware units.

A replacement panel will not control attached machinery until the corresponding ESA Crew runtime project file is loaded. Maintenance personnel must transfer the original project file via network, USB flash drive, or MicroSD card, ensuring that communication IP addresses, serial baud rates, and protocol node IDs match the machine configuration.

Frequently Asked Questions

Which programming software is used with the ESA EW107ND4SP000FR panel?

The panel uses the ESA Crew Programming Suite for application engineering and project configuration.

How can I restore an application project onto a replacement EW107ND4SP000FR?

Projects can be transferred over an Ethernet connection using the Crew software, or restored offline using a FAT32-formatted USB flash drive or MicroSDHC card.

What power supply voltage is required for the EW107ND4SP000FR?

The unit operates on a nominal 24 V DC power supply, with an acceptable operational range between 18 V DC and 32 V DC.

What serial protocols and pinouts are supported on the serial port?

The single DE-9 male serial port is software-configurable to support RS232, RS485, or RS422 communication standards.

What communication protocols are supported over network connections?

The panel supports standard drivers including Modbus TCP, Modbus RTU, and EtherNet/IP, with options for PROFINET and CANopen.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of ESA.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.