Lenze 9324MP.1B.62.V01 Control Board – 9300 Servo Series

New 
On request
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo | Series: 9300 Master Position

The Lenze 9324MP.1B.62.V01 is a servo controller control board designed for the Lenze 9300 Servo family, specifically for 9300 Master Position servo inverters. Operating on a nominal 24 V DC control supply drawing 1 A, this plug-in control module attaches directly to Lenze 9300 power section units to deliver high-precision motion control, electronic gearing, registration mark positioning, and synchronized master-slave multi-axis positioning. It serves as the primary processing unit for motor feedback evaluation, terminal I/O processing, and system communication across packaging, textile, printing, converting, and machine tool automation systems.

For physical interface integration, the board features 8 digital inputs, 4 digital outputs, 2 bipolar analog inputs (-10 V to +10 V with 12-bit resolution), and 2 bipolar analog outputs. Motor feedback is routed through a 15-pin Sub-D connector supporting resolvers with a 10 kHz evaluation frequency, as well as SinCos absolute encoders and incremental encoders. Networking across drive axes is provided via an onboard CAN system bus operating up to 500 kbps on terminals X4 and X5. A dedicated Automation Interface slot on the front accepts optional communication modules like PROFIBUS-DP (EMF2131IB or EMF2133IB), INTERBUS, LECOM, or an EMF2102IB keypad module. Putting a spare unit into service requires parameter transfer, as the board stores up to four non-volatile parameter sets (PAR0 through PAR3) in internal EEPROM memory using Lenze Global Drive Control (GDC V4.x+) or EASY Starter software. ABC Industrial Parts can assist in sourcing fully tested replacement units and managing parameter extraction to restore motion sequences smoothly.

Diagnostic conditions are visually indicated by two front panel LEDs. A green READY LED illuminates solid when the drive is enabled and operational, flashes when in the controller-inhibited IMP state, and turns off if the control supply fails or an internal board fault occurs. A red TRIP LED stays solid during active fault conditions that inhibit drive output, flashes for warnings, and remains off during normal operation. Detailed fault tracking is accessible via keypad display, GDC or EASY Starter diagnostic views, or the fault history buffer stored in codes C0161 through C0168. When experiencing critical system failures such as an internal micro-controller system error (code H05) or persistent EEPROM corruption (code EEr), internal hardware components are not field-serviceable, making drive board replacement or professional repair through ABC Industrial Parts the most efficient path back to production.

Technical Specifications

ManufacturerLenze
Part Number9324MP.1B.62.V01
Model / TypeControl Board
Component TypeServo Controller Board
Product Family9300 Servo
Control Supply Voltage24 V DC
Control Supply Current1 A
Digital Inputs8
Digital Outputs4
Analog Inputs2 (-10 V to +10 V, 12-bit)
Analog Outputs2 (Bipolar)
System Bus ProtocolCAN / Lenze System Bus
System Bus Speed500 kbps
Resolver Input Frequency10 kHz

Programming and Configuration

Configuration of the Lenze 9324MP.1B.62.V01 control board relies on Lenze Global Drive Control (GDC version 4.x or higher) or EASY Starter engineering software tools. The control board contains non-volatile EEPROM memory capable of holding up to four distinct parameter sets, designated PAR0 through PAR3. This multi-parameter architecture allows users to store backup configurations directly on the board or switch operational profiles for flexible machinery setups.

When commissioning or replacing a module, parameters can be transferred electronically via PC connected over fieldbus/communication interfaces, or copied directly using an EMF2102IB plug-in keypad module. Reading parameter sets from a donor or existing control board and transferring them to a replacement unit ensures that motor control loops, I/O mapping, and motion profiles are mirrored without manual re-entry.

Communication and System Integration

System communication on the 9324MP.1B.62.V01 control board is anchored by an integrated Lenze CAN system bus interface, routed through terminals X4 and X5. Operating at transmission speeds up to 500 kbps, this interface enables synchronized master-slave axis coupling and high-speed multi-axis motion networks across Lenze 9300 servo drives. Proper line termination using 120 Ohm resistors at both physical ends of the bus is required to maintain reliable signal integrity.

Higher-level fieldbus integration is achieved through the front Automation Interface (AIF) expansion slot. This slot accommodates modular fieldbus adapters including PROFIBUS-DP interfaces (EMF2131IB and EMF2133IB), INTERBUS, and LECOM RS-232 or RS-485 communication cards. Interfacing options allow seamless connection to central PLCs, master controllers, and human-machine interfaces without modifying the core control hardware.

Diagnostics and Status Indication

The board provides immediate visual feedback via two dedicated LED indicators on the front panel. System status and operational states can also be monitored digitally using the EMF2102IB keypad module, the GDC diagnostic monitor, or EASY Starter software. Internal diagnostic logs are continuously updated in a non-volatile fault history memory buffer spanning codes C0161 to C0168, allowing maintenance staff to trace past operational faults and warning events chronologically.

Status LED Indicators

LEDColor/StatusMeaning
Green LED (READY / Operation)Green - Solid / FlashingON: Drive enabled and running. Flashing: Controller inhibited (IMP state), ready for operation. OFF: Control supply missing or internal board fault.
Red LED (TRIP / Fault)Red - Solid / FlashingON: Fault condition active (TRIP), drive output inhibited. Flashing: Warning or message condition active. OFF: No active trip/warning.

Replacement and Spare Part Considerations

Replacing a Lenze 9324MP.1B.62.V01 control board requires matching the exact part number to ensure hardware and firmware compatibility with the underlying 9300 servo power section. Because the board handles motor feedback routing, terminal assignments, and fieldbus communication, swapped units must be configured with the specific parameter file (PAR0 to PAR3) corresponding to the machine application before operating connected motors.

Prior to mounting a replacement board, technical staff should verify that all optional fieldbus modules (such as PROFIBUS EMF2131IB/EMF2133IB) or keypads are securely seated in the front AIF slot. Wiring connections across control terminals, resolver/encoder ports (terminal X6, X8/X9), and the CAN system bus (terminals X4/X5) must be verified, ensuring correct 120 Ohm termination resistors are present on the CAN bus to prevent communication timeouts.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short Circuit / OvercurrentShort circuit or severe overcurrent detected in motor cables or output stageShort circuit in motor cable; short circuit in motor windings; output stage overloadCheck motor wiring and insulation; check motor windings for phase-to-phase short; verify drive sizing
OC2Earth FaultGround fault detected on power output terminalsGround leak in motor winding or cable; ground contact in motor connection boxCheck insulation resistance of motor and power cables relative to PE ground
OC5Ixt OverloadDrive continuous overload protection limit exceededDrive operated above rated current for too long; mechanical stall or excessive load torqueCheck mechanical drive train for binding; optimize acceleration ramps; check current rating
OUOvervoltage DC BusDC bus voltage exceeded upper threshold valueExcessive regenerative energy during deceleration; deceleration ramp too short; brake chopper or braking resistor defective/missingExtend deceleration time; install or inspect external braking resistor and brake chopper
LUUndervoltage DC BusDC bus voltage fell below lower threshold valueMains supply voltage drop or failure; supply phase loss; internal precharge circuit faultCheck mains voltage supply and fuses; check AC input wiring; verify power section operation
OHHeatsink OvertemperaturePower section heatsink temperature exceeded maximum allowable limit (>90°C)Cooling fan defective; heatsink clogged; ambient temperature too high; inadequate enclosure ventilationClean heatsink cooling fins; verify enclosure airflow; inspect internal cooling fan operation
OH4Motor OvertemperatureMotor temperature sensor input triggered overtemperature faultMotor thermal overload; mechanical binding; thermal sensor trip (PTC or KTY open)Allow motor to cool down; inspect motor cooling/fan; check thermal sensor connections on terminals X6/X7
OH7Motor Temp Sensor Wire BreakWire break detected in motor temperature sensor lineInterrupted conductor or disconnected terminal for motor thermal sensorInspect temperature sensor wiring and connections; check sensor resistance value
CE0Communication Error AIFInterrupted communication between control board and AIF moduleFieldbus communication module missing, loose, or damaged; bus timeoutCheck seating of AIF communication module in front slot; inspect fieldbus cable and termination
CE1Communication Error CAN System Bus 1Communication error on onboard CAN system bus interfaceBus cable disconnected; missing termination resistor (120 Ohm); incorrect baud rate settingInspect CAN system bus connections on terminals X4/X5; verify 120 Ohm line termination at both bus ends
EErEEPROM Memory ErrorInternal EEPROM parameter memory fault / checksum errorPower failure during parameter write operation; hardware EEPROM failure on control boardReload factory parameter defaults; download parameter set from backup file. If fault persists, board hardware is defective — replace control board.
H05Internal Hardware FaultInternal board micro-controller system error / hardware fault detectedControl board component failure or processor faultInternal hardware fault — board is not field-serviceable; return unit for factory repair or replace control board.
Sd1Resolver Feedback FaultResolver signal open circuit, short, or invalid track signalResolver cable damaged or disconnected; resolver sensor fault in motorInspect resolver cable connections on terminal/socket X6; check shield ground continuity; check resolver windings
Sd2Incremental Encoder FaultIncremental encoder signal track error or missing pulsesEncoder cable broken; encoder supply missing or overloaded; defective encoderCheck encoder wiring and supply voltage on terminal X8/X9; replace encoder or connection cable
Sd3SinCos Encoder FaultAbsolute / SinCos encoder track error or absolute value transmission failureSinCos encoder interface failure; defective serial communication line; noisy encoder signalVerify shielding and ground connection of SinCos encoder cable; check encoder supply voltage
NMAXSpeed ExceededActual motor speed exceeded maximum permissible limit settingInappropriate controller gain parameters; speed loop instability; external mechanical driving loadCheck speed controller parameter settings; verify encoder feedback calibration; check driven mechanics
PIPhase FailureMains supply input phase failure detectedMissing phase on main supply line; blown supply fuseCheck AC supply voltage across all input phases; inspect mains fuses and contactors

Frequently Asked Questions

What software is required to configure the Lenze 9324MP.1B.62.V01 control board?

Parameter configuration and diagnostic monitoring are performed using Lenze Global Drive Control (GDC version 4.x or higher) software or EASY Starter. Parameters can also be transferred directly using an EMF2102IB keypad module.

What motor feedback types are supported by this control board?

The board supports resolvers via a 10 kHz evaluation interface on a 15-pin Sub-D connector, as well as SinCos absolute encoders and incremental encoders connected to terminals X8/X9.

How are parameter sets stored on the 9324MP.1B.62.V01?

Parameter sets are saved in non-volatile internal EEPROM memory, which holds up to four complete parameter sets (PAR0 through PAR3) for rapid parameter backup and swapping during maintenance.

What fieldbus options can be used with this control board?

Fieldbus communication is expandable via the front Automation Interface (AIF) slot, which accepts PROFIBUS-DP modules (EMF2131IB / EMF2133IB), INTERBUS, and LECOM RS-232/RS-485 interfaces, in addition to the built-in 500 kbps CAN system bus on terminals X4/X5.

What does fault code H05 indicate on the drive display?

Code H05 signifies an internal micro-controller system error or hardware fault. This indicates an internal component failure that is not field-serviceable, requiring control board repair or replacement.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.