SICK 1044074 FX0-GPNT00000 Flexi Soft PROFINET Gateway Module
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The SICK 1044074 FX0-GPNT00000 is a Flexi Soft PROFINET IO gateway module designed to integrate modular safety controller diagnostic and status data into higher-level industrial automation networks. Operating as a PROFINET IO Device, this communication module bridges non-safety operational signals and system status from the Flexi Soft safety system directly to programmable logic controllers. The module draws its 24 V DC power directly through the internal flexBUS backplane plug from the FX3-CPU main module, operating with a low power consumption of 2.5 W. Featuring an integrated two-port Ethernet switch with dual RJ45 female connectors, the FX0-GPNT00000 supports linear and ring fieldbus topologies without requiring standalone external switches.
Connecting the module into an active network involves dual RJ45 fieldbus ports supporting 100 Mbit/s full-duplex communication in accordance with PROFINET Conformance Class B specifications. When commissioning a replacement unit in an existing machine, configuration parameters are maintained centrally within the FX3-CPU main module plug and automatically transferred across the flexBUS backplane upon startup. Bringing a spare module into service typically requires establishing network device naming or IP address assignment using SICK Flexi Soft Designer software or standard engineering tools such as Siemens TIA Portal and STEP 7. Technicians can rely on support from ABC Industrial Parts when sourcing pre-tested replacement units and verifying configuration transfer routines.
System operational health and network activity are displayed via four multi-color status LEDs located on the front panel. The ST LED indicates internal module status and initialization, while the BUS LED reflects PROFINET fieldbus link and configuration conditions. Dual L1/A1 and L2/A2 LEDs confirm physical link presence and active data transmission across both Ethernet ports. In addition to local visual indications, diagnostic messages are broadcast across the flexBUS to the FX3-CPU and forwarded as PROFINET IO diagnostic alarms to the master PLC controller. If a solid red ST indicator signifies an unrecoverable internal hardware fault, internal component repairs are not field-serviceable, making swap-out with a replacement unit from ABC Industrial Parts the recommended path to minimize machine downtime.
Technical Specifications
| Manufacturer | SICK |
| Part Number | 1044074 |
| Model / Type | FX0-GPNT00000 |
| Product Family | Flexi Soft |
| Component Type | PROFINET Gateway Module |
| Supply Voltage | 24 V DC |
| Power Consumption | 2.5 W |
| Transmission Rate | 100 Mbit/s |
| Communication Protocol | PROFINET IO (Conformance Class B) |
| Fieldbus Interface | 2x RJ45 female (Integrated 2-port switch) |
| Internal System Bus | flexBUS backplane plug |
Programming and Configuration
Parameterization of the SICK 1044074 FX0-GPNT00000 gateway is managed through SICK Flexi Soft Designer software. System parameters and gateway settings are saved centrally in the main FX3-CPU module memory plug rather than on the gateway itself, ensuring that parameter structures remain unified across the modular safety assembly.
When integrating the gateway with a higher-level PLC, device configuration files such as GSDML files are imported into engineering environments like Siemens TIA Portal or STEP 7. Network node identification and IP address assignments are established during this setup phase to enable seamless cyclic data exchange between the PROFINET IO Controller and the Flexi Soft system.
Communication and System Integration
The FX0-GPNT00000 gateway features an integrated two-port Ethernet switch operating at 100 Mbit/s full-duplex speed. Equipped with dual RJ45 female connectors, it supports both line and ring network architectures directly on the machine floor, eliminating the need for standalone external network switches.
Operating under PROFINET Conformance Class B specifications, the module provides reliable transmission of safety system status, diagnostic information, and non-safety operational data to higher-level PLC systems. On the backplane side, the module communicates directly via the flexBUS interface, which handles high-speed internal data exchange and power delivery from the FX3-CPU module.
Diagnostics and Status Indication
Visual troubleshooting on the SICK 1044074 FX0-GPNT00000 is facilitated by four front-panel LED indicators that offer immediate status clarity for module health, fieldbus activity, and physical link connections. In addition to visual indication, diagnostic messages are routed through the flexBUS backplane into the Flexi Soft Designer software diagnostic window.
Higher-level diagnostic integration is supported by PROFINET IO diagnostic alarms, which report communication disruptions, configuration mismatches, or hardware issues directly into the PLC master controller diagnostic buffer in engineering tools such as Siemens STEP 7 or TIA Portal.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| ST | Green / Red - Solid / Flashing / Off | Module Status: Solid Green = Normal operation; Flashing Green = Configuration required / Initialization; Solid Red = Internal module fault; Off = No supply power |
| BUS | Green / Red - Solid / Flashing / Off | PROFINET Fieldbus Status: Solid Green = Online, connection established with IO Controller; Flashing Green = Online, no connection with IO Controller; Solid Red = Bus error / Duplicate IP / Invalid configuration; Off = Offline / No connection |
| L1 / A1 | Green - Solid / Flashing / Off | Link / Activity Port 1: Solid Green = Physical connection established; Flashing Green = Data traffic active on Port 1; Off = No physical link |
| L2 / A2 | Green - Solid / Flashing / Off | Link / Activity Port 2: Solid Green = Physical connection established; Flashing Green = Data traffic active on Port 2; Off = No physical link |
Replacement and Spare Part Considerations
Replacing a damaged FX0-GPNT00000 gateway is simplified by the centralized configuration architecture of the SICK Flexi Soft platform. Because all operational parameters reside in the main FX3-CPU module, mounting a replacement gateway onto the flexBUS backplane triggers an automatic configuration download during initialization.
Maintenance personnel must verify that the replacement unit carries the matching part number 1044074 and model designation FX0-GPNT00000. Following hardware physical replacement, the network IP address and PROFINET device name must be reassigned via Flexi Soft Designer or the PLC engineering tool to complete fieldbus network re-integration.
Frequently Asked Questions
What is the main function of the SICK 1044074 FX0-GPNT00000 module?
The SICK 1044074 FX0-GPNT00000 serves as a PROFINET IO gateway for SICK Flexi Soft safety systems. It enables higher-level PLCs to access diagnostic, status, and non-safety operational data from safety controller modules.
Does the FX0-GPNT00000 require an external power supply wiring connection?
No, the FX0-GPNT00000 draws its 24 V DC supply power directly from the internal flexBUS backplane connected to the FX3-CPU main module, consuming up to 2.5 W.
How are parameters configured when replacing an FX0-GPNT00000 module?
Parameters are stored centrally in the FX3-CPU main module plug. Upon installing a replacement FX0-GPNT00000 module, configuration data is automatically downloaded across the flexBUS backplane, requiring only network device naming or IP assignment through Flexi Soft Designer or PLC engineering tools.
What network topologies are supported by the FX0-GPNT00000 Ethernet interfaces?
Thanks to its integrated two-port Ethernet switch with dual RJ45 connectors, the module supports both line and ring network topologies at 100 Mbit/s full-duplex communication according to PROFINET Conformance Class B standards.
What diagnostic tools are available for troubleshooting the FX0-GPNT00000 gateway?
Diagnostics can be monitored visually using the four front-panel LEDs (ST, BUS, L1/A1, L2/A2), through the Flexi Soft Designer diagnostic window, via flexBUS messages to the FX3-CPU, or through PROFINET IO diagnostic alarms logged in the PLC system buffer.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Sick.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.