Phoenix Contact 2753601 IBS RT 24 DIO 16/16-T Digital I/O Module

New 
On request
Refurbished   
On request
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: INTERBUS | Series: Ruggedline

The Phoenix Contact 2753601 IBS RT 24 DIO 16/16-T is a decentralized digital I/O module within the INTERBUS family, engineered for heavy-duty field deployment directly on machinery. Enclosed in a zinc die-cast housing rated at IP67, this unit operates reliably in harsh industrial environments without requiring an auxiliary control cabinet. The module integrates 16 digital inputs supporting 2-, 3-, or 4-wire connection technology and 16 digital outputs delivering up to 0.5 A per channel at a nominal supply voltage of 24 V DC. Standard M12 circular connectors handle sensor and actuator signals, protecting terminal connections against dust, liquids, and mechanical stress in automotive, packaging, and assembly applications.

Connecting a replacement unit into an active fieldbus line relies on the copper twisted-pair interface operating at a transmission rate of 500 kbit/s. Local and remote bus communication lines link directly through standard industrial connectors to the host INTERBUS master controller. Integrating a spare unit into the network requires system alignment using CMD or Config+ engineering software to verify fieldbus addressing, bus frame structure, and controller diagnostic parameters. Because fieldbus modules interface directly with operational machine logic, replacing a failed unit requires confirming that bus topology and master configurations match the donor station before restoring system power. ABC Industrial Parts can assist in sourcing fully tested replacement modules and verifying hardware compatibility for legacy fieldbus installations.

System status and channel diagnostics are continuously monitored via integrated LED indicators on the face of the housing. The UL LED indicates logic supply voltage above the 18.5 V DC minimum operating limit, while US indicates the presence of the 24 V DC sensor and actuator power. Bus communication state is reflected by the BA indicator, and the RD LED illuminates yellow when downstream bus segments are disabled. Short circuits or overloads on output channels OUT 1..16 light up red, and the FAIL / ERR indicator warns of peripheral or network faults. First-line troubleshooting involves checking input supply voltages, verifying IP67 connector tightness, and scanning master diagnostic registers. If logic supply parameters are correct but internal hardware failures persist, replacing the module or securing a tested exchange unit from ABC Industrial Parts offers the fastest route back to full production.

Technical Specifications

ManufacturerPhoenix Contact
Part Number2753601
Model / TypeIBS RT 24 DIO 16/16-T
Component TypeDigital I/O Module
Product FamilyINTERBUS
Supply Voltage (Nominal)24 V DC
Supply Voltage Range18.5 - 30.2 V DC
Output Voltage (Nominal)24 V DC
Output Current per Channel0.5 A
Digital Inputs16
Digital Outputs16
Fieldbus ProtocolINTERBUS
Transmission MediumCopper (Twisted Pair)
Data Transfer Rate500 kbit/s
Connector Type (I/O)M12 Circular Connector
Housing MaterialZinc Die-Cast
Ingress Protection RatingIP67

Programming and Configuration

Engineering and configuring the Phoenix Contact 2753601 IBS RT 24 DIO 16/16-T is performed using CMD or Config+ software tools. The module operates as a dedicated station on the INTERBUS network, requiring precise logical mapping within the controller address configuration.

During commissioning or module replacement, the master controller identifies the device based on its predefined position in the bus topology. System engineers must verify that I/O address mapping corresponds to machine logic programs and that controller diagnostic registers accurately reflect standard operational parameters across all 16 input and 16 output channels.

Communication and System Integration

The module incorporates an INTERBUS copper remote and local bus interface designed for high-speed data transfer at rates up to 500 kbit/s. Standardized twisted-pair copper cabling connects the module directly to upstream and downstream network nodes without necessitating external bus converters.

Physical bus connections utilize IP67-rated circular connectors to preserve signal integrity and shield communications against severe electromagnetic interference. The -T suffix designates copper-medium connectivity, rendering the unit fully compatible with standard INTERBUS copper remote and local bus master controllers.

Diagnostics and Status Indication

The IBS RT 24 DIO 16/16-T incorporates an array of diagnostic LEDs directly on the front panel. Status lights indicate logic power status (UL), sensor/actuator supply status (US), bus activity (BA), downstream bus segment disable status (RD), and general module or network error conditions (FAIL / ERR).

Individual channel indicators monitor all 16 digital inputs (IN 1..16) and 16 digital outputs (OUT 1..16). Yellow LEDs signal active high-level logic, while a red output LED warns of channel-specific short-circuit or overload conditions, enabling rapid fault identification at the machine level.

Status LED Indicators

LEDColor/StatusMeaning
ULGreen / Off - Green: Logic supply present | Off: Supply missing/failureLogic supply voltage status
USGreen / Off - Green: 24V present | Off: Supply missingSensor/actuator supply voltage status
BAGreen / Off - Green: Bus active | Off: No communicationINTERBUS bus activity status
RDYellow - SolidRemote bus disabled / downstream bus segment switched off
FAIL / ERRRed - Solid / FlashingModule error, peripheral fault, output overload/short circuit, or bus diagnostic fault
IN 1..16Yellow - SolidInput signal active (High level at input terminal)
OUT 1..16Yellow / Red - Yellow: Active signal | Red: Short circuit or overloadOutput status and channel fault indication

Replacement and Spare Part Considerations

When swapping out a damaged Phoenix Contact 2753601 module, ensure the replacement unit matches the exact IBS RT 24 DIO 16/16-T designation and copper transmission specifications (-T). Because the device is mounted directly on machine frames without protective cabinets, verify that all IP67 housing seals and M12 cable connectors are fully torqued to prevent moisture or particulate ingress.

Prior to reconnecting power, check that the main power supply supplies a stable voltage within the 18.5 V DC to 30.2 V DC window. After replacing the physical hardware, use CMD or Config+ software tools to confirm that the INTERBUS master recognizes the node position and clears any peripheral or communication error registers.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
Peripheral Fault (PF)Peripheral Fault / Short CircuitShort circuit or overload detected at one or more digital output channels, or failure of sensor supply voltage US.Actuator wiring short circuit, defective output load, sensor power supply line disconnected or below threshold.Check M12 output cables and connected loads for short circuits; verify 24 V DC sensor/actuator supply voltage US.
Bus Warning / Bus ErrorINTERBUS Communication FaultTransmission error or interruption detected on the INTERBUS copper segment.Damaged copper bus cable, loose IP67 bus connector, high electromagnetic interference, fault in upstream module.Check network cable integrity and shield termination; verify IP67 bus plug connection.
Logic Voltage Fault (UL Low)Logic Supply UndervoltageModule internal logic supply voltage dropped below minimum operating limit (18.5 V DC).Main 24 V DC power supply failure, excessive voltage drop on supply line, internal power converter defect.Check supply voltage at module power input terminals. If input voltage is correct but UL LED remains off, internal hardware fault — replace the unit.

Frequently Asked Questions

Which software is used to configure the Phoenix Contact 2753601 module?

The IBS RT 24 DIO 16/16-T module is configured and diagnosed using standard INTERBUS engineering software, such as CMD or Config+.

What type of network medium does this module require?

This module features a copper twisted-pair interface (-T variant) for INTERBUS communication at data rates up to 500 kbit/s.

What does a red illumination on an OUT status LED indicate?

A red light on an OUT LED indicates a short circuit or overload fault condition on that specific digital output channel.

Can this module be installed directly on a machine without a cabinet?

Yes, the module is housed in a heavy-duty zinc die-cast enclosure rated at IP67, engineered specifically for direct field mounting on machinery.

What is the acceptable supply voltage range for the logic power input?

The module operates on a nominal 24 V DC supply, with an acceptable operating range between 18.5 V DC and 30.2 V DC.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Phoenix Contact.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.