Lenze 00387070 EZN3A1500H003 3-Phase Mains Choke
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze 00387070 EZN3A1500H003 is a 3-phase mains choke from the Lenze EZN Series, engineered to filter supply voltage harmonics upstream of variable frequency drives. Operating on 3-phase AC power networks up to 480 V at 50/60 Hz, this line reactor delivers a rated inductance of 15 mH with a continuous current capacity of 3 A. By dampening peak inrush currents and buffering against grid voltage surges, the choke protects sensitive inverter input rectifiers and DC bus capacitors across industrial environments such as packaging machinery, material handling, textile manufacturing, and automotive assembly lines.
Field integration is straightforward thanks to heavy-duty screw terminals for 3-phase mains input, load output, and direct protective earth grounding connections. As a purely passive power conditioning component, commissioning a replacement EZN3A1500H003 requires no parameter configuration, software tools, firmware alignment, or memory backups. Swapping a unit involves standard electrical isolation, disconnecting terminal wiring, mounting the substitute hardware, and reattaching the power lines. ABC Industrial Parts can assist maintenance teams by supplying prompt replacement hardware to keep critical drive systems running smoothly.
Practical troubleshooting focuses on primary electrical and thermal checks across the installation. Technicians should verify that the incoming line voltage remains within the maximum 480 V AC rating, inspect screw terminals for proper torque and tight electrical contact, and ensure panel enclosure airflow accommodates the 18 W full-load power dissipation. If internal winding damage or an open-circuit fault occurs, the assembly cannot be serviced on the component level; installing a tested replacement unit from ABC Industrial Parts provides a direct route back to reliable drive operation.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | 00387070 |
| Model / Type | EZN3A1500H003 |
| Product Family | EZN Series |
| Component Type | 3-Phase Mains Choke |
| Inductance | 15 mH |
| Rated Current | 3 A |
| Maximum Supply Voltage | 480 V AC |
| Number of Phases | 3 |
| Mains Frequency | 50/60 Hz |
| Power Loss | 18 W |
| Termination Type | Screw Terminal |
Replacement and Spare Part Considerations
When replacing a line reactor in existing Lenze 8200 or 9300 series frequency inverter applications, matching the electrical ratings is critical. The Lenze 00387070 EZN3A1500H003 provides 15 mH of inductance at a rated continuous current of 3 A and is intended for 3-phase AC systems up to 480 V at 50/60 Hz. Substituting a choke with insufficient current or inductance ratings may result in increased harmonic distortion, higher drive operating temperatures, or premature inverter failure.
Because this mains choke is a passive component, zero parameter transfer or software initialization is required during replacement. Installation consists of isolating panel power, removing the failed unit, securing the new choke, and making heavy-duty screw terminal connections for mains input, load output, and protective earth. Ensure thermal clearance in the cabinet is adequate to dissipate the 18 W nominal heat loss during continuous 3 A operation.
Frequently Asked Questions
What is the function of the Lenze 00387070 EZN3A1500H003 mains choke?
The Lenze 00387070 EZN3A1500H003 is a 3-phase mains choke that filters grid harmonics, limits peak inrush currents, and protects variable frequency drives from transient voltage spikes.
Which drive series are compatible with the Lenze 00387070 line reactor?
This line reactor is commonly used with Lenze 8200 Series and Lenze 9300 Series frequency inverters on standard 3-phase 400 V / 480 V AC supply networks.
Does replacing the EZN3A1500H003 require programming or firmware updates?
No. The EZN3A1500H003 is a purely passive device that requires zero software setup, parameter adjustments, or firmware configuration.
What are the key electrical specifications for the Lenze 00387070?
It features a rated current of 3 A, inductance of 15 mH, maximum operating voltage of 480 V AC across 3 phases at 50/60 Hz, and a typical power loss of 18 W.
How is the Lenze 00387070 choke connected mechanically and electrically?
Electrical wiring is attached via robust screw terminals covering mains input lines, load output lines to the inverter, and a dedicated protective earth ground connection.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.