Product Family: 8200 vector | Series: 8200 vector

The Lenze 00384223 EVF8202-E-V002 is a 0.75 kW AC frequency inverter belonging to the 8200 vector product family, designed for speed control of standard three-phase AC motors. Operating from a supply voltage range of 180 V AC to 264 V AC, this IP20-rated drive delivers a three-phase 230 V AC output with a continuous current rating of 4.0 A and a peak overload current of 6.0 A for up to 60 seconds. It supports selectable V/f characteristic control as well as sensorless vector control, achieving precise motor dynamics up to a maximum output frequency of 480 Hz at an 8 kHz switching frequency with 45 W power loss.

Integrating the inverter into control systems relies on its onboard I/O terminals, which feature 4 programmable digital inputs, 1 digital output, 1 configurable analog input, 1 analog output, and 1 dedicated TRIP relay contact. For network integration, the drive includes a modular Function Interface (FIF) expansion slot that accepts plug-in fieldbus communication modules, such as PROFIBUS (E82ZAFP), System Bus CANopen (E82ZAFC), or LECOM (E82ZAFL). When commissioning a replacement drive, parameter configurations must be transferred to match the operational setup. The drive features an internal EEPROM capable of storing up to four independent parameter sets, which can be configured using Global Drive Control (GDC) software or a Keypad XT (E82ZBC / EMZ8201BB) module. Technical assistance from ABC Industrial Parts can support users during spare unit preparation and configuration transfer.

Diagnostic feedback is provided directly on the front panel via a dual-LED indicator, where a solid green LED indicates normal operation or ready status, and a solid red LED signals an active TRIP fault state. Detailed fault monitoring is accessible through diagnostic parameters C0161 to C0168 or the Keypad fault memory log, which tracks error conditions such as DC bus undervoltage (LU), heatsink overtemperature (OH), or communication errors (CE0). Basic field checks include verifying line supply voltages, checking motor load and cabling insulation, and confirming the mechanical seating of plug-in modules. When internal hardware errors occur, such as short-circuit fault OC1 or internal hardware failure H05, board-level components are not field-serviceable, making unit repair or a tested replacement drive from ABC Industrial Parts the effective path back to production.

Technical Specifications

ManufacturerLenze
Part Number00384223
Model / TypeEVF8202-E-V002
Product Family8200 vector
Component TypeFrequency Inverter
Supply Voltage Range180 - 264 V AC
Output Voltage230 V AC (3-phase)
Rated Power0.75 kW
Continuous Output Current4.0 A
Maximum Output Current6.0 A (150% for 60s)
Maximum Output Frequency480 Hz
Switching Frequency8 kHz
Power Loss45 W
Digital Inputs4
Digital Outputs1
Analog Inputs1
Analog Outputs1
Relay Outputs1
Enclosure RatingIP20

Programming and Configuration

The Lenze 00384223 EVF8202-E-V002 frequency inverter is configured using Lenze Global Drive Control (GDC) software or directly through an optional plug-in Keypad XT module (E82ZBC / EMZ8201BB). The drive incorporates an internal EEPROM that maintains parameter memory without external power, supporting storage for up to four complete, independent parameter sets for flexible machine commissioning.

During drive replacement, parameter settings must be transferred from the original unit or saved backup file to mirror the required control profile. Using GDC software or the Keypad XT, parameter sets can be downloaded, adjusted, or restored to factory defaults using parameter C0002. Parameter set errors, such as fault code P12, indicate an incomplete parameter transfer that requires re-sending the configuration file.

Communication and System Integration

System integration for the EVF8202-E-V002 drive is supported through hardwired terminal connections and fieldbus expansion capabilities via its Function Interface (FIF) slot. Physical terminal connections include 4 programmable digital inputs, 1 digital output, 1 analog input configurable for voltage or current signals, 1 analog output, and 1 relay output for TRIP fault signaling.

The modular FIF expansion slot enables direct attachment of plug-in communication modules to integrate into centralized automation networks. Compatible options include the Lenze PROFIBUS module (E82ZAFP), System Bus CANopen module (E82ZAFC), and LECOM module (E82ZAFL) supporting RS232 or RS485 interfaces. Proper mechanical seating and termination of these option modules are required to prevent communication faults such as code CE0.

Diagnostics and Status Indication

Drive operation and fault status are monitored on the front panel of the Lenze 00384223 inverter via a dual-LED indicator array. The green LED signals operational readiness or active drive status, while the red LED alerts technicians to active TRIP fault conditions.

Advanced diagnostics are accessible using the Keypad XT fault memory log or GDC software, which tracks documented TRIP faults alongside diagnostic parameters C0161 through C0168. These parameters display real-time internal status values and historical error logs for systematic fault isolation.

Status LED Indicators

LEDColor/StatusMeaning
TRIP / FaultRed - Solid / ActiveFault or trip condition detected
Operation status / ReadyGreen - Solid / ActiveDrive in normal operation or ready state

Replacement and Spare Part Considerations

When replacing an existing Lenze 00384223 (EVF8202-E-V002) drive, ensuring matching hardware specifications and parameter configurations is essential. The replacement unit must match the 0.75 kW power rating, 180–264 V AC supply range, and 4.0 A continuous output current to ensure safe and continuous motor control.

Prior to placing a replacement drive into service, parameter settings must be transferred from the original unit using Global Drive Control (GDC) software or a Keypad XT module. Additionally, any optional fieldbus communication module installed in the original Function Interface (FIF) slot—such as PROFIBUS (E82ZAFP), CANopen (E82ZAFC), or LECOM (E82ZAFL)—must be moved to the spare drive and fully seated.

As the Lenze 8200 vector series is phased out, users evaluating long-term equipment maintenance or modernization can also consider recommended successor options from the Lenze i510 and i550 cabinet frequency inverter series.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OHHeatsink OvertemperatureHeatsink temperature exceeds permitted limit.Ambient temperature too high; cooling fan dirty or defective; inadequate cabinet ventilation; continuous heavy overload.Improve cooling/ventilation; clear heatsink obstruction; check ambient temperature; reduce load.
OH4Motor Overtemperature (PTC)Motor temperature sensor triggered via control terminals T1/T2.Motor overload; motor cooling fan failure; incorrect PTC connection.Allow motor to cool down; check load and thermal motor protection setting; inspect motor fan.
LUUndervoltage DC BusDC bus voltage dropped below minimum threshold during operation.Mains supply voltage too low; main supply phase failure; mains power interruption.Check supply line voltage; verify input wiring and fuses.
OUOvervoltage DC BusDC bus voltage exceeded maximum allowable threshold.Excessive regenerative energy from motor during deceleration; deceleration ramp too short.Extend deceleration time (C0013); install brake chopper / braking resistor module.
OC1Short Circuit / Earth FaultOvercurrent triggered by short circuit or ground fault at motor terminals.Short circuit in motor cable; insulation breakdown in motor winding; ground fault.Inspect motor cabling and motor windings for insulation damage or short circuit. If error persists with motor disconnected, internal power module hardware is damaged — return unit for repair.
OC2Acceleration OvercurrentPeak current limit exceeded during motor acceleration phase.Acceleration time set too short; motor mechanically stalled or overloaded.Increase acceleration time (C0012); check motor dimensioning and mechanical load.
OC5Drive Overload (Ixt)Ixt thermal overload of inverter power stage accumulated.Inverter operated above continuous rated current for extended duration.Check drive sizing; reduce motor load or duty cycle.
H05Internal Hardware FaultInternal electronic component or control board malfunction detected.Internal power supply fault or microcontroller communication failure.Internal hardware failure — not field-serviceable. Replace drive or contact Lenze service.
EEREEPROM FaultEEPROM checksum or read/write memory failure.EEPROM corrupted due to voltage drop during parameter save or hardware fault.Load factory default parameters; power cycle drive. If failure persists, internal memory board is defective — replace unit.
P12Parameter Set ErrorIncomplete or corrupted parameter set loaded.Interrupted transfer from keypad/GDC or incompatible firmware parameters.Re-transfer parameter set or reset drive to factory defaults (C0002).
CE0Communication Error (Automation Module)Communication interruption between inverter base unit and plug-in communication module.Module loose, defective cable, or protocol timeout.Check mechanical seating of function module; verify fieldbus wiring and termination.
LPMains Phase FailureFailure of one supply phase detected.Mains fuse blown or input line interruption.Check mains voltage on all input phases.

Frequently Asked Questions

How are parameters saved and transferred on the Lenze 00384223 inverter?

Parameters can be saved and transferred using Lenze Global Drive Control (GDC) software or an optional Keypad XT module (E82ZBC / EMZ8201BB). The internal EEPROM stores up to four parameter sets, allowing configurations to be backed up and reloaded during unit replacement.

What communication modules fit into the FIF expansion slot of the EVF8202-E-V002?

The Function Interface (FIF) slot supports plug-in communication modules including the Lenze PROFIBUS module (E82ZAFP), System Bus CANopen module (E82ZAFC), and LECOM module (E82ZAFL) for RS232 or RS485 communication.

What should be checked if the drive displays an OC1 fault code?

Fault code OC1 signals a short circuit or earth fault at the motor terminals. Inspect the motor cabling and motor windings for insulation breakdown or short circuits. If the error remains active after disconnecting the motor leads, the internal power module is damaged and requires unit repair or replacement.

What are the primary power and voltage ratings for the Lenze 00384223 drive?

The drive accepts a single or three-phase supply voltage of 180 to 264 V AC, producing a three-phase 230 V AC output. It has a rated power of 0.75 kW, continuous output current of 4.0 A, and a maximum overload current of 6.0 A for 60 seconds.

What modern inverter series serves as a successor to the legacy 8200 vector drive?

The recommended modern successor series for legacy 8200 vector frequency inverters like the EVF8202-E-V002 are the Lenze i510 and i550 cabinet series drives.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.