Lenze 00490376 E82EV222_4C 8200 Vector Frequency Inverter

New 
On request
Refurbished   
2 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 vector | Series: 8200 vector

The Lenze 00490376, model type E82EV222_4C, is a 2.2 kW frequency inverter designed for precise speed and torque control of 4-pole AC asynchronous motors within the Lenze 8200 vector family. Built for control cabinet installation with an IP20 enclosure rating, this compact drive operates across a 3-phase supply voltage range of 320 V AC to 528 V AC at 400/480 V nominal. It delivers a continuous output current of 5.6 A and supports a 150% overload capacity up to 8.4 A for 60 seconds. The drive provides an output frequency range from 0 Hz to 480 Hz with an 8 kHz switching frequency, utilizing linear or square-law V/f control alongside sensorless vector modes for dynamic performance in material handling, conveyor systems, packaging machinery, and fan or pump drives.

Integrating the Lenze 00490376 into an existing machine relies on its modular design, which separates the power stage base unit from interchangeable function modules. Fieldbus integration and external I/O expansion are handled via plug-in modules such as the E82ZAFSC, E82ZAFCC, E82ZAFPC, or E82ZAFDC, supporting communication protocols like CANopen, PROFIBUS-DP, RS232/485 LECOM, and DeviceNet. Commissioning a replacement unit requires transferring operational parameters, as drives are not plug-and-play out of the box. Keypad modules such as the E82ZBC or E82ZBB XT, or Global Drive Control (GDC) software, are used to configure settings or upload stored parameter profiles. The internal EEPROM can hold up to four switchable parameter sets, allowing quick adaptation to different operating conditions. ABC Industrial Parts can support maintenance teams in sourcing the correct unit and backing up or transferring stored drive parameters.

Diagnostic status monitoring on the unit is provided through built-in front panel LEDs and software memory registers. A green LED indicates controller readiness or active motor operation, while a red LED signals warnings or fault trips. Detailed fault history is stored in internal parameters C0161 through C0164, accessible via keypad or fieldbus monitoring. The drive reports specific fault codes for events such as overcurrent during acceleration (OC1), deceleration (OC2), or steady speed (OC5), DC bus overvoltage (OU) or undervoltage (LU), heatsink overtemperature (OH), motor thermal overload (OH4), supply mains phase loss (LP1), and fieldbus communication loss (CE0). When hardware-level trip codes like H05 or internal memory errors occur, board-level faults cannot be serviced in the field. Sourcing a tested replacement or utilizing repair services through ABC Industrial Parts ensures a reliable return to operational status.

Technical Specifications

ManufacturerLenze
Part Number00490376
Model / TypeE82EV222_4C
Product Family8200 vector
Component TypeFrequency Inverter
Rated Power2.2 kW
Supply Voltage Range320 - 528 V AC
Rated Continuous Output Current5.6 A
Maximum Output Current8.4 A
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz
Power Dissipation90 W
Ingress Protection RatingIP20

Programming and Configuration

The Lenze 00490376 frequency inverter utilizes Global Drive Control (GDC) software for engineering, parameter management, and system commissioning. Connection to a host PC is established via compatible LECOM RS232/485 communication adapters or fieldbus interface modules. GDC provides comprehensive visual access to drive parameters, dynamic diagnostics, and online control functions, streamlining setup and fine-tuning of motor control parameters.

For local parameter adjustment and operator control, the drive supports plug-in keypad units, including the standard E82ZBC keypad and the extended E82ZBB XT keypad. These plug-in modules fit directly onto the front function slot, enabling parameter modification, operational status checks, and fault history inspection without external software. The internal non-volatile EEPROM memory stores up to four independent parameter sets, which can be selected dynamically via digital inputs or fieldbus commands to accommodate varying product runs or operational modes.

Communication and System Integration

System integration with the Lenze 00490376 is achieved through its modular function module architecture. Rather than fixed, built-in communication terminals, the drive features a dedicated front slot that accepts plug-in fieldbus interface modules. Supported modules include the E82ZAFSC, E82ZAFCC, E82ZAFPC, and E82ZAFDC, which enable network connectivity over CANopen, PROFIBUS-DP, DeviceNet, and RS232/485 LECOM protocols.

This modular physical interface allows the drive to integrate directly into higher-level PLC architectures and distributed industrial networks. Network integration enables real-time speed setpoint transmission, drive enable commands, reading of diagnostic registers, and parameter read/write operations over the fieldbus. Proper communication setup requires configuring the corresponding bus address switches or software parameters to match network master configuration.

Diagnostics and Status Indication

The drive includes two integrated status LEDs on the front panel to provide immediate visual feedback on operational state and active conditions. The green LED signals drive readiness when flashing (controller inhibit active) and continuous motor operation when solid. The red LED flashes to indicate an active warning or impending trip condition, and illuminates continuously when a fault trip has occurred.

In addition to visual LED indications, the inverter maintains a historical error buffer within parameters C0161 through C0164, accessible via plug-in keypads (E82ZBC or E82ZBB XT) or GDC software. Diagnostic data and detailed error codes can also be read over CANopen or other fieldbus networks to assist centralized control systems with real-time fault tracking and root-cause analysis.

Status LED Indicators

LEDColor/StatusMeaning
Green LEDGreen - Flashing / ContinuousFlashing = Controller inhibit (IMP) / Ready; Continuous = Drive running / Enabled
Red LEDRed - Flashing / ContinuousFlashing = Warning / Active condition; Continuous = Trip / Active fault

Replacement and Spare Part Considerations

When replacing a failed Lenze 00490376 (E82EV222_4C) drive, maintenance personnel must ensure that the existing plug-in function module (such as E82ZAFSC or E82ZAFPC) is transferred from the old unit to the replacement drive. Because the drive base unit contains the power section and main control board, transferring the fieldbus module preserves physical wiring connections while maintaining network node addresses if stored on hardware DIP switches.

A replacement drive must be loaded with the parameter configuration of the original unit prior to putting the machine back into service. Parameter profiles can be transferred by saving and loading settings via Global Drive Control (GDC) software or by utilizing a keypad module with copy capability. Because factory default settings will not match application-specific motor parameters, acceleration ramps, or I/O assignments, restoring a valid configuration backup is critical to prevent improper motor operation or fieldbus faults.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short Circuit / Overcurrent AccelerationOutput current exceeded overcurrent threshold during acceleration phase.Short circuit or earth fault on motor cable; acceleration time set too short; motor damaged.Check motor cable and winding insulation; increase acceleration time parameter; verify motor size.
OC2Overcurrent DecelerationOutput current exceeded threshold during deceleration phase.Deceleration time set too short; brake chopper not functioning or braking resistor missing/damaged.Increase deceleration time; check brake chopper / external braking resistor.
OC5Overcurrent Constant SpeedOutput current exceeded overcurrent limit during constant speed run.Abrupt load change; mechanical blockage or overload on motor shaft.Check mechanical load for jams or overload conditions; inspect motor wiring.
OUDC Bus OvervoltageDC bus voltage exceeded upper limit threshold.Regenerative energy from motor during deceleration; deceleration ramp too short; mains voltage too high.Extend deceleration time; install or connect braking resistor; check mains supply voltage.
LUDC Bus UndervoltageDC bus voltage fell below lower limit threshold.Supply mains failure; voltage dip; supply phase loss; input fuses blown.Check input mains voltage; verify power wiring and fuses.
OHHeatsink OvertemperatureDrive heat sink temperature exceeded maximum allowed limit.Inadequate cabinet ventilation; ambient temperature too high; cooling fins clogged with dust/debris; fan failure.Clean heat sink fins; improve cabinet cooling/ventilation; verify internal fan function.
OH4Motor Overheating / PTC TriggeredMotor thermistor/PTC sensor connected to drive detected motor overheating.Motor thermal overload; continuous operation at low speeds without forced cooling.Allow motor to cool down; check mechanical load; check motor PTC thermistor wiring.
LP1Mains Phase FailureDrive detected loss of one of the 3 input supply phases.Blown supply fuse; loose input wiring connection; phase imbalance on power grid.Check supply line fuses, power wiring, and line voltage balance.
NMAXOverspeed FaultMotor output speed exceeded maximum speed setpoint.Incorrect slip compensation or vector control tuning; external load driving motor.Check motor parameter settings; verify speed limits and load dynamics.
EEInternal EEPROM ErrorParameter checksum error in internal EEPROM parameter storage.Interrupted parameter saving process; internal memory corruption.Reload factory default settings (C0002 = 1); re-commission parameter set. If fault persists, internal hardware defect requires drive replacement.
EErExternal Error SignalTrip triggered via digital input assigned to external error signal function.External monitoring device (e.g. safety relay or external sensor) opened trip contact.Check external fault circuit connected to drive digital inputs.
CE0Communication Error / Fieldbus FaultInterruption of data transmission via function module / fieldbus interface.Fieldbus master stopped; broken communication cable; plug connection loose; incorrect baud rate.Check fieldbus wiring, terminal bus power, and master controller communication state.
H05Internal Hardware FaultInternal hardware or micro-controller check failed during self-test.Internal electronic board failure or corrupted micro-controller system.Internal board-level failure — unit is not field-serviceable and must be returned for repair or replaced.

Frequently Asked Questions

What is the main replacement requirement for a Lenze 00490376 inverter?

To replace a Lenze 00490376 (E82EV222_4C) drive, you must transfer the existing plug-in function module to the spare unit and restore the application parameters using Global Drive Control (GDC) software or a plug-in keypad.

Which communication protocols are supported by the Lenze 00490376?

The drive supports CANopen, PROFIBUS-DP, DeviceNet, and RS232/485 LECOM communication through plug-in function modules such as the E82ZAFSC, E82ZAFCC, E82ZAFPC, and E82ZAFDC.

What do the status LEDs on the Lenze 00490376 indicate?

The green LED indicates drive state (flashing for controller inhibit/ready, solid for drive running), while the red LED indicates warnings when flashing and active fault trips when illuminated continuously.

What should I check if fault code OU appears on the display?

Fault code OU indicates DC bus overvoltage. You should check if the deceleration time is set too short, verify whether a braking resistor is connected and functioning, and measure the incoming mains supply voltage.

What does fault code H05 mean on the Lenze 00490376?

Fault code H05 indicates an internal hardware failure detected during self-test. This internal electronic error cannot be serviced in the field, requiring repair or drive replacement.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.