Lenze 00490461 E82EV371_2C 8200 Vector Frequency Inverter

New 
On request
Refurbished   
On request
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 vector | Series: 8200 vector

The Lenze 00490461 (model E82EV371_2C) is a 0.37 kW AC frequency inverter from the Lenze 8200 vector family, engineered for speed, torque, and position control in automated machinery. Operating on an input supply range of 180 V to 264 V AC across single-phase or three-phase line feeds, this compact IP20-rated variable frequency drive delivers a continuous rated output current of 2.4 A at an 8 kHz switching frequency. It supports flexible motor control modes, including linear or quadratic V/f characteristic curves, dynamic sensorless vector control, and direct torque control. With a 150% dynamic overload reserve capable of supplying 3.6 A for up to 60 seconds, the drive is suited for demanding motor starting conditions in packaging lines, material handling conveyors, and industrial pump or fan systems.

The E82EV371_2C features a modular architecture that relies on pluggable function modules to define physical I/O terminals and network connectivity. When commissioning a replacement drive, field technicians must transfer or reconfigure the specific interface module—such as the E82ZAFSC Standard I/O, E82ZAFCC CANopen, or E82ZAFPC PROFIBUS module—to match the original installation. Drive parameters are managed using the Keypad XT (E82ZBC) operator panel or Lenze Global Drive Control (GDC) PC software. The inverter contains internal non-volatile EEPROM memory capable of holding up to four independent parameter sets. When replacing a damaged unit, parameters can be cloned directly from existing backups or extracted from donor memory, a service supported by ABC Industrial Parts to help minimize machine downtime.

Operational monitoring and troubleshooting are supported through dual LED status indicators on the front panel alongside internal diagnostic buffers. A green LED signals power and operational state, while a red LED indicates warnings or active trip faults. Detailed fault diagnosis is accessible via the Keypad XT display, GDC software diagnostic windows, or the internal fault history buffer spanning memory locations C0161 to C0164. Common issues such as acceleration overcurrent (OC1) or DC bus overvoltage (OU) can often be resolved by adjusting acceleration (C0012) or deceleration (C0013) ramp times. If persistent hardware errors like EEPROM corruptions (EEH) or power stage defects (H05) occur, internal component repairs are required. In these situations, sourcing a fully tested replacement drive or utilizing expert repair services through ABC Industrial Parts ensures swift production recovery.

Technical Specifications

Supply Voltage Range180 - 264 V AC
Rated Power0.37 kW
Rated Output Current2.4 A
Max Output Current3.6 A
Power Loss28 W
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz
IP RatingIP20

Programming and Configuration

Configuring the Lenze 00490461 frequency inverter is accomplished using either the plug-in Keypad XT (E82ZBC) display panel or Lenze Global Drive Control (GDC) engineering software connected via a PC interface. The unit features non-volatile internal EEPROM memory that stores up to four complete, independent parameter sets, allowing multi-purpose application configurations within a single drive.

During setup and commissioning, key operating parameters can be adjusted to optimize motor control and drive dynamics. Critical parameter codes include C0012 for setting acceleration ramp times and C0013 for deceleration ramp times. Field technicians can quickly download parameter backups to GDC software or copy stored parameter profiles directly between drives using the Keypad XT module.

Communication and System Integration

The Lenze 8200 vector series utilizes a pluggable Function Module (FIF) system to integrate the drive into automated control architectures. The base E82EV371_2C inverter unit requires an attached interface module to establish control terminal signals or fieldbus connection points.

Supported expansion interface options include the E82ZAFSC Standard I/O module for hardwired digital and analog control, the E82ZAFCC module for CANopen networking, and the E82ZAFPC module for PROFIBUS-DP connectivity. System integrators can also utilize LECOM and Modbus RTU protocol modules to enable serial communication across broader automation networks.

Diagnostics and Status Indication

The drive provides status indication via front-panel LEDs alongside parameter-based diagnostic monitoring tools. Real-time diagnostic data can be viewed through the Keypad XT text display, the GDC software diagnostic window, or by monitoring internal status words.

For historical fault analysis, the drive records recent trip events in a designated fault history buffer across parameters C0161 through C0164. This allows maintenance personnel to review fault sequences and diagnose recurring operational issues.

Status LED Indicators

LEDColor/StatusMeaning
Ready / Power (Green LED)Green - Blinking / SolidBlinking: Mains supply connected and inverter ready. Solid: Drive operational / enabled.
Fault / Trip (Red LED)Red - Blinking / SolidBlinking: Warning or trouble condition detected. Solid: Critical fault / trip active, power stage disabled.

Replacement and Spare Part Considerations

When swapping out a failed Lenze 00490461 drive, care must be taken to match both the base power section and the installed pluggable function module. The replacement drive chassis must match the 0.37 kW 230V specifications of the E82EV371_2C model to ensure correct thermal and electrical ratings.

Before putting a spare unit into operation, the existing function module (such as E82ZAFSC, E82ZAFCC, or E82ZAFPC) must be transferred to the replacement unit, or an equivalent module must be installed and configured. Parameter settings stored in the internal EEPROM must be uploaded to the replacement drive using either the Keypad XT panel or GDC software to restore original machine operations.

For modern system retrofits or complete machine upgrades where legacy 8200 vector units are being phased out, Lenze recommends the i510 or i550 inverter series as direct successor platforms. However, installing a direct-replacement 00490461 unit avoids panel wiring modifications and control program alterations.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Overcurrent during accelerationOutput current exceeded the dynamic overcurrent limit during acceleration phaseShort circuit or ground fault at output, acceleration ramp time too short, motor cable too longCheck motor cable and motor winding insulation, extend acceleration time (C0012)
OC2Overcurrent during decelerationOutput current exceeded limit during deceleration phaseDeceleration ramp time too short, excessive load inertiaExtend deceleration time (C0013), check braking dynamic requirements
OC5Overcurrent during steady operationOutput current exceeded peak threshold during constant speed operationAbrupt mechanical load surge, defective motor, earth faultInspect mechanical load, motor insulation, and output wiring
OUDC bus overvoltageDC bus circuit voltage exceeded maximum voltage thresholdDeceleration ramp too steep, regenerative energy from motor too highExtend deceleration time (C0013), connect external brake chopper and resistor
LUDC bus undervoltageDC bus circuit voltage fell below minimum voltage thresholdMains supply failure, supply voltage too low, blown input fuseCheck mains voltage, input fuses, and wiring
OHHeatsink overtemperatureHeatsink temperature exceeded safety thresholdAmbient temperature too high, cooling fan blocked/failed, heatsink dirtyClean heatsink, improve enclosure ventilation, check cooling fan operation
OH4Motor overtemperatureMotor PTC thermal sensor trippedMotor thermal overload, insufficient motor coolingAllow motor to cool down, reduce motor load, check motor fan
OH7Inverter thermal overload (I x t)Calculated thermal overload limit of inverter reachedContinuous operation above nominal rated currentReduce continuous output load, check drive sizing
EEHEEPROM memory faultInternal EEPROM checksum error or parameter storage failureCorrupted non-volatile memory or hardware defect on control boardInternal hardware fault — reload factory default parameters; if persistent, return unit for repair or replace inverter
H05Internal hardware faultPower stage or gate driver hardware fault detectedInternal component failure on power boardInternal hardware fault — unit is not field-serviceable; return unit for repair or replace inverter

Frequently Asked Questions

What is the continuous power rating and input voltage requirement for the Lenze 00490461 inverter?

The Lenze 00490461 (E82EV371_2C) drive has a rated output power of 0.37 kW and requires an AC mains input voltage ranging from 180 V to 264 V AC.

How are parameter settings transferred to a replacement E82EV371_2C unit?

Parameter sets can be downloaded using Lenze Global Drive Control (GDC) PC software or transferred directly using the Keypad XT (E82ZBC) display module. Up to four complete parameter sets can be stored in the drive's non-volatile EEPROM memory.

What functional modules are compatible with this drive for I/O and communication?

The drive supports pluggable modules including the E82ZAFSC Standard I/O module, E82ZAFCC CANopen module, E82ZAFPC PROFIBUS module, and LECOM/Modbus RTU serial interface modules.

What does an 'OU' fault code indicate on the Lenze 8200 vector drive?

An 'OU' fault indicates a DC bus overvoltage condition, often caused by excessively fast deceleration or regenerative energy returning from the motor. Recommended actions include extending deceleration time (C0013) or installing an external brake chopper and resistor.

Can internal hardware faults such as H05 or EEH be repaired in the field?

Fault codes H05 (internal hardware defect) and persistent EEH (EEPROM memory error) indicate internal circuit board or power stage failures that are not field-serviceable. The drive must be repaired by a technician or replaced with a tested unit.

What modern Lenze drive series is recommended as a successor to the 8200 vector series?

Lenze recommends the i510 and i550 frequency inverter series as modern replacement alternatives for legacy 8200 vector installations.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.