Lenze 00490725 E82MV251_2B001 8200 Motec Frequency Inverter 0.25kW

New 
1 available for direct collection
Refurbished   
On request
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 vector | Series: 8200 Motec

The Lenze 00490725, model designation E82MV251_2B001, is a decentralized frequency inverter belonging to the 8200 vector product family and 8200 Motec series. Rated for a continuous output power of 0.25 kW (0.33 HP) with an output current of 1.7 A, this compact drive operates on 230 V AC single-phase or three-phase supply configurations across an input tolerance range of 180 V to 264 V AC. Built with an IP65 rated enclosure, the unit is constructed for direct mounting on standard AC asynchronous motors or localized wall installation on machine frames. This decentralized design eliminates central control cabinet requirements, shortens motor wiring runs, and reduces electromagnetic interference across applications such as conveyor belts, industrial pumps, fans, and material handling systems.

To facilitate system integration, the E82MV251_2B001 utilizes a modular interface structure that separates the core drive control section from fieldbus interface modules. The drive supports pluggable modules for CANopen, PROFIBUS-DP, INTERBUS, and AS-Interface networks without altering the base drive module. Commissioning a replacement unit requires parameter set configuration, as up to four complete parameter sets can be stored inside internal non-volatile EEPROM memory. Parameter management and configuration transfers are performed using the optional XT Keypad module (E82ZBC) or Lenze Global Drive Control (GDC) PC software. When restoring a machine to service, parameter set copying and correct function module seating are key steps, with ABC Industrial Parts providing expert support and tested spare units to simplify replacement.

Diagnostics and operating status are displayed via an integrated dual Red/Green status LED that indicates drive state, standby mode, warnings, and TRIP conditions. The inverter tracks active diagnostic data and logs the last four TRIP events with operating hour timestamps, accessible via parameter C0161 for active faults and parameter C0168 for fault history using a keypad or GDC software. Trip indications cover issues such as acceleration overcurrent (OC1), DC bus overvoltage (OU), motor overtemperature (OH4), and module slot communication faults (CE0). While initial maintenance involves checking mains supply wiring, line fuses, motor connections, and external sensor circuits, internal control board issues like EEPROM corruption (EE) or microcontroller failure (H05) are non-serviceable in the field. Under these conditions, sourcing a tested exchange drive or unit repair through ABC Industrial Parts provides a direct route back to full operation.

Technical Specifications

ManufacturerLenze
Part number00490725
Model / TypeE82MV251_2B001
Component typeFrequency Inverter
Product family8200 vector
Series8200 Motec
Rated power0.25 kW
Supply voltage1/N/PE AC 230 V / 3/PE AC 230 V
Supply voltage range180 V to 264 V AC
Rated output current1.7 A
Maximum output current2.55 A (150% overload for 60 s)
Switching frequency8 kHz
Output frequency range0 Hz to 480 Hz
Ingress protection ratingIP65

Programming and Configuration

Parameter setup and configuration management for the Lenze 00490725 frequency inverter are conducted through Lenze Global Drive Control (GDC) PC software or locally via the optional XT Operating Module (E82ZBC) keypad. The drive includes non-volatile EEPROM memory capable of retaining up to four independent parameter sets. This feature allows different machine configuration profiles to be stored directly within the drive and swapped as operational requirements demand.

When commissioning or replacing an E82MV251_2B001 inverter, parameter sets must be transferred from the original unit or downloaded from a saved software project. If resetting the device to default conditions is required during testing, executing parameter C0002 = 1 restores factory settings. Proper motor thermal characteristics must also be configured in parameters C0087 and C0088 to match connected motor ratings and prevent false thermal overload TRIP conditions.

Communication and System Integration

The E82MV251_2B001 features a modular communication layout where network interface modules plug into the dedicated control slot on the front of the drive. This architectural separation allows the core power electronics and frequency drive logic to remain intact while swapping fieldbus interfaces as machine control architectures evolve.

Available interface options for the 8200 Motec platform include CANopen, PROFIBUS-DP, INTERBUS, and AS-Interface modules. Reliable network integration depends on verifying full mechanical engagement between the module and header pins, as well as proper cable grounding and shielding. A loss of communication between the core inverter logic and the plugged module triggers fault code CE0.

Diagnostics and Status Indication

Visual operational feedback on the Lenze 00490725 drive is provided by a dual Red/Green status LED. The LED emits continuous or flashing patterns to indicate normal drive running states, standby status, active operational warnings, or tripped fault conditions.

For detailed fault analysis, current drive errors are viewed in parameter C0161 via the XT Keypad or GDC PC software online window. Historical troubleshooting is supported by parameter C0168, which records the last four TRIP codes alongside their exact operating hour timestamps. This historical log assists technicians in isolating intermittent trip causes such as momentary overvoltage or thermal overloads.

Status LED Indicators

LEDColor/StatusMeaning
Status LEDsRed / Green - Solid / FlashingIndicates operational state, standby mode, active warnings, and TRIP faults

Replacement and Spare Part Considerations

The Lenze 8200 Motec series, including part number 00490725, is officially discontinued by the manufacturer. For existing automated facilities maintaining legacy production lines, sourcing direct replacement spares minimizes physical installation modifications due to the specialized IP65 form factor. For complete machine redesigns or long-term system modernizations, Lenze recommends the i550 protec series as a modern replacement option.

When swapping out a faulty unit for a replacement 00490725 drive, parameter sets must be transferred using either the XT Keypad or Global Drive Control software. An unconfigured drive or an invalid parameter upload will result in a P13 fault code, while improper module insertion leads to a CE0 error. Verifying physical pin condition on the module slot header prior to mounting ensures reliable fieldbus communications.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Acceleration OvercurrentOutput current exceeded peak limit during acceleration rampShort circuit at output terminals, earth fault on motor cable, motor cable too long, acceleration time setting too shortCheck motor and cable for short circuits and ground faults; increase acceleration time; check motor size matching.
OC2Deceleration OvercurrentOutput current exceeded peak limit during deceleration rampDeceleration time set too short; mechanical overload or jammed motor shaftIncrease deceleration time; install brake resistor if applicable; check mechanical drive train.
OC5I2t Motor OverloadMotor load exceeded I2t thermal limit over timeContinuous operation under overload conditions, motor under-dimensioned, low motor speed with excessive loadReduce motor load; check drive sizing; verify parameter C0087/C0088 thermal characteristic settings.
OUDC Bus OvervoltageDC bus voltage exceeded upper threshold (~400V for 230V devices)Regenerative energy from motor during braking with deceleration time too shortExtend deceleration ramp time (C0013); check brake resistor / chopper circuit.
LUDC Bus UndervoltageDC link voltage dropped below lower operation thresholdMains supply failure, supply voltage drop under load, loose mains connectionCheck supply voltage mains; check fuses and wiring connections.
OHInverter OvertemperatureHeatsink temperature exceeded upper limit (> 90°C)Inadequate cooling air flow, ambient temperature too high, heavy continuous overloadClean heatsink cooling fins; improve cabinet/mounting ventilation; reduce switching frequency or load.
OH4Motor Temperature FaultMotor thermal sensor (PTC/TK) detected overheatingMotor thermal overload, cooling fan failure on motor, incorrect PTC wiring or sensor setupAllow motor to cool down; check motor load and forced ventilation fan; verify PTC connection on terminals.
OH7Internal Thermal Monitoring FaultInternal power section temperature reached critical thresholdAmbient temperature around inverter exceeds spec; internal hardware degradationCheck installation environment and cooling. If persistent without external heat, internal board failure requiring unit repair/replacement.
EEEEPROM Memory FaultInternal non-volatile parameter memory error detected during power-up or write processCorrupted EEPROM memory, power interrupted during parameter save operation, internal memory hardware faultPerform factory parameter reset (C0002 = 1). If fault cannot be reset, non-serviceable internal failure — replace unit.
H05Internal Hardware FailureControl board or micro-controller internal fault detected during self-testInternal circuit failure or component malfunctionInternal hardware fault — not field-serviceable. Replace the unit or return for repair.
CE0Communication Fault Module SlotCommunication breakdown between inverter CPU and attached function moduleFunction module improperly seated, defective module, EMI disturbanceCheck module seating on connector header; verify grounding and shielding; replace function module.
ERLExternal Fault SignalExternal fault triggered via configured digital input terminalExternal monitoring device (e.g. safety switch, external relay) openedCheck external signal source connected to input terminal configured as TRIP set.
P13Parameter Set FaultInconsistent parameter set loaded into active parameter setIncomplete transfer or invalid parameter value writtenRe-download valid parameter set or restore factory default settings.

Frequently Asked Questions

What tools are used to program and configure the Lenze 00490725 inverter?

The Lenze 00490725 (E82MV251_2B001) is configured using Lenze Global Drive Control (GDC) PC software or locally using the optional XT Operating Module (E82ZBC) keypad.

How are drive parameters transferred to a replacement unit?

Up to four parameter sets stored in the internal EEPROM can be saved and transferred using the XT Keypad module or uploaded and downloaded via Global Drive Control (GDC) software.

Which fieldbus communication protocols are supported?

The drive supports pluggable communication modules for CANopen, PROFIBUS-DP, INTERBUS, and AS-Interface networks via its front interface slot.

What actions should be taken if an EE fault code appears?

An EE fault indicates an EEPROM memory issue. Attempt a factory parameter reset by setting parameter C0002 = 1. If the fault persists after resetting power, the internal memory hardware has failed and the drive unit must be replaced.

What is the recommended modern successor for the 8200 Motec series?

Lenze recommends transitioning to the i550 protec series for modern replacement and upgrade applications.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.