Lenze 13131452 E82MV251_2B001 8200 Motec Frequency Inverter

New 
1 available for direct collection
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 motec | Series: 8200 motec

The Lenze 13131452 (type designation E82MV251_2B001) is a 0.25 kW frequency inverter from the 8200 motec series designed for decentralized motor speed control. Operating with a rated input supply voltage of 230 V AC across a 180 to 264 V AC range, this drive delivers a continuous output current of 1.7 A and an output frequency range of 0 to 480 Hz. Housed in a heavy-duty IP65 enclosure that protects against dust and moisture, the unit supports direct mounting onto a motor terminal box or adjacent wall mounting, eliminating the need for space-consuming centralized control cabinets in conveyor systems, packaging machinery, and pumping applications.

To integrate with automation networks and control architectures, the E82MV251_2B001 features a modular interface slot that accepts plug-in communication modules including CANopen (E82ZAFCC), PROFIBUS (E82ZAFPC), and AS-Interface (E82ZAFAC), as well as DeviceNet and LECOM RS-232/485. Putting a spare drive into service requires parameter alignment to match the original application setup, as standard units will not operate machine profiles without configuration. Parameters can be backed up and downloaded using Lenze Global Drive Control (GDC) software or copied directly using the Keypad XT (EMF2171IB / E82ZBC) parameter cloning feature across four non-volatile EEPROM memory sets. ABC Industrial Parts can support maintenance teams with replacement units and parameter management guidance to minimize downtime during drive swap-outs.

Diagnostics are indicated directly on the drive cover by status LEDs, where a solid green light indicates normal ready operation and a red light signals an active fault condition. Internal fault memory parameters C0161 and C0168 store a log of trip events readable via the Keypad XT or GDC software monitor. When diagnosing trips such as overvoltage (OU), undervoltage (LU), motor phase loss (LP1), or module communication timeouts (CE0, CE1, CE2), initial checks should cover main AC voltage stability, motor terminal connections, fieldbus wiring, and module seating. If persistent EEPROM errors (EEr) or internal hardware failures occur that cannot be cleared by restoring factory defaults (C0002 = 1), a tested exchange unit from ABC Industrial Parts offers a fast solution to restore production.

Technical Specifications

ManufacturerLenze
Part Number13131452
Model / TypeE82MV251_2B001
Product Family8200 motec
Component TypeFrequency Inverter
Rated Power0.25 kW
Supply Voltage230 V AC
Supply Voltage Range180 - 264 V AC
Continuous Output Current1.7 A
Output Voltage0 - 230 V AC
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz (Adjustable 2 - 16 kHz)
Control MethodV/f characteristic (linear, quadratic), sensorless vector control
Protection RatingIP65
Mounting TypeMotor-mounted / Wall-mounted

Programming and Configuration

Drive configuration and operating setup for the Lenze E82MV251_2B001 are performed using either Lenze Global Drive Control (GDC) software or a plug-in Keypad XT (EMF2171IB / E82ZBC). The inverter is equipped with internal non-volatile EEPROM memory capable of storing up to four independent, switchable parameter sets. Control algorithms can be configured for linear or quadratic V/f characteristic curves as well as sensorless vector control, with adjustable switching frequencies from 2 kHz up to 16 kHz to optimize acoustic motor performance.

During routine drive swaps or commissioning, the Keypad XT parameter cloning function allows complete parameter profiles to be copied directly from one unit to another without a PC connection. If software reconfiguration or memory re-initialization is required, setting parameter C0002 to 1 reloads the factory default parameter set into the EEPROM, providing a clean baseline for application re-programming.

Communication and System Integration

The Lenze 8200 motec E82MV251_2B001 utilizes a modular architecture built around an integrated plug-in interface slot. This design enables flexible adaptation to diverse industrial automation systems without altering the base power unit. Depending on system requirements, optional function modules can be attached to support fieldbus protocols including CANopen (E82ZAFCC), PROFIBUS (E82ZAFPC), AS-Interface (E82ZAFAC), DeviceNet, and LECOM RS-232/485.

Internal communication between the drive control board and the installed module is maintained via direct plug connectors. Correct seating of the function module and accurate configuration of bus parameters, node addresses, and baud rates on the network master are required to maintain continuous data exchange and prevent fieldbus interface timeout errors.

Diagnostics and Status Indication

Visual operational status on the E82MV251_2B001 is provided by diagnostic LEDs located on the drive cover. A solid green 'Ready' LED indicates normal operation and readiness for run commands, while a solid or flashing red 'Fault' LED signals an active trip condition. Real-time operating variables and active status states can also be monitored via Lenze Global Drive Control (GDC) or the EMF2171IB Keypad XT display.

Detailed fault records are retained in internal diagnostic registers. Codes recorded in history parameters C0161 and C0168 assist maintenance staff in identifying conditions such as motor overcurrent (OC1), earth faults (OC2), DC bus overvoltage (OU), undervoltage (LU), or thermal overloads (OH, OH4, OH8).

Status LED Indicators

LEDColor/StatusMeaning
ReadyGreen - SolidInverter operating normally / Ready for operation
FaultRed - Solid / FlashingInverter fault / trip condition active

Replacement and Spare Part Considerations

When replacing a failed Lenze E82MV251_2B001 drive, verify both the part number (13131452) and the full type designation to guarantee electrical and physical compatibility. Selecting a unit with matching power ratings (0.25 kW) and voltage specifications (230 V AC) ensures proper motor power delivery and mechanical alignment when mounted to a motor terminal box.

During unit replacement, any plug-in fieldbus module attached to the interface slot must be transferred to the replacement inverter or reconfigured to match network communication parameters. Additionally, parameter data stored in the original drive's EEPROM must be transferred using the Keypad XT cloning feature or Global Drive Control (GDC) software to restore motor settings, acceleration profiles, and control terminal assignments.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuitShort circuit on motor output power terminals or excessive peak current.Short circuit in motor winding or motor cable; ground fault; acceleration ramp too short.Check motor and motor wiring for short circuits/earth faults; lengthen acceleration time; verify motor sizing.
OC2Earth faultGround fault detected on motor connection side.Ground fault in motor winding or motor supply lead; excessive cable capacitance.Check motor cable and motor insulation resistance to earth/ground.
OC5I x t overloadContinuous current overload exceeded max load limit.Drive overloaded; mechanical overload/jam; motor current continuously above drive rated current.Check machine mechanics for blockages; verify drive load profile and motor rating.
OUOvervoltageDC bus voltage exceeded upper overvoltage threshold.Excessive regenerative energy during deceleration; deceleration time too short; supply voltage too high.Increase deceleration ramp time; check mains voltage; install brake chopper / brake resistor if applicable.
LUUndervoltageDC bus voltage fell below undervoltage limit.Supply mains voltage too low; main supply phase loss; power failure.Check main AC power supply voltage and input fuse/wiring.
OHHeatsink temperature highInverter power section / heatsink temperature exceeded permissible limit.Inadequate cooling / ventilation space; ambient temperature too high; dirty heatsink cooling fins.Clean heatsink fins; ensure proper ventilation clearance; check ambient operating temperature.
OH4Motor temperature switch / PTC tripMotor thermistor switch (PTC or thermal contact) tripped due to overheating.Motor thermal overload; insufficient motor cooling; PTC sensor cable damaged or open circuit.Allow motor to cool; check motor load and cooling fan; verify thermistor wiring.
OH7Drive internal temperature excessiveInternal air / board temperature inside the inverter is too high.Excessive ambient temperature; internal hardware fan failure.Improve ambient cooling; check installation space and enclosure cooling.
OH8Motor I2t thermal overloadCalculated motor thermal load (I2t) exceeded upper threshold.Motor operated at low speed with high continuous current without forced ventilation.Reduce motor load or use forced-ventilation fan on motor; check parameter C0075 / C0076 motor setup.
EErEEPROM memory errorParameter data in internal EEPROM corrupted or checksum fault.Power failure during parameter write process; internal memory hardware failure.Reload factory default parameter set (C0002 = 1); reprogram parameters. Internal hardware failure — return unit for repair if fault persists.
CE0Communication error - general module / interfaceCommunication interruption between inverter and plug-in function module or fieldbus.Loose module connector; faulty function module; bus communication timeout.Check function module seating; check fieldbus cable and termination resistors; check timeout settings.
CE1System bus (CAN) communication errorSystem bus / CAN module bus error or offline timeout.CAN network cable broken or disconnected; baud rate mismatch; missing termination resistor.Verify CANbus wiring, shield grounding, baud rate setting, and node address.
CE2Function module communication timeoutInterprocess communication failure with function module.Defective function module or internal motherboard communication path.Reseat function module. If fault persists, replace function module or internal drive board — return unit for repair.
LP1Motor phase failureMissing output phase on motor side detected.Motor cable wire disconnected; motor winding open circuit; very small motor connected.Check motor cables and terminal connections; check motor winding resistance.
NMAXMaximum speed exceededMotor actual speed exceeded maximum speed setpoint limit.Regenerative overspeed drive load; incorrect speed feedback parameter setting.Check maximum frequency setting (C0011) and load mechanics.

Frequently Asked Questions

How do I transfer parameters from a failed Lenze E82MV251_2B001 to a replacement drive?

Parameter settings can be cloned directly using the plug-in Keypad XT (EMF2171IB / E82ZBC) by copying the parameter set from the original unit or backup memory and restoring it to the new drive. Alternatively, Lenze Global Drive Control (GDC) software can be used to upload, save, and download parameter profiles.

What fieldbus protocols are supported by the Lenze 13131452 drive?

The drive supports plug-in function modules for CANopen (E82ZAFCC), PROFIBUS (E82ZAFPC), AS-Interface (E82ZAFAC), DeviceNet, and LECOM RS-232/485.

What does a solid red Fault LED indicate on the inverter?

A solid or flashing red Fault LED indicates an active trip condition, such as overcurrent, overvoltage, undervoltage, or a communication error. Specific trip information can be retrieved from internal parameters C0161 and C0168 via Keypad XT or GDC software.

How can the drive be reset to its factory default parameters?

Factory default parameters are reloaded into internal EEPROM memory by setting parameter C0002 to 1 through Keypad XT or Global Drive Control (GDC) software.

Is the Lenze E82MV251_2B001 drive suitable for direct motor mounting?

Yes, the drive features an IP65 protection rating designed specifically for direct mounting on motor terminal boxes or decentralized wall mounting in industrial environments.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.