Lenze 13325140 EVS9327-ES 9300 Servo Drive

New 
On request
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo

The Lenze EVS9327-ES (part number 13325140) is an 11 kW standalone servo drive within the Lenze 9300 Servo series, engineered for precise speed and torque regulation in automated industrial production lines. Designed for a three-phase main supply voltage of 400 to 480 V AC (with an operating input range of 320 to 528 V AC), this IP20-rated controller provides a continuous output current of 24 A and a peak current limit of 36 A for up to 60 seconds. Utilizing high-efficiency field-oriented vector control and an 8 kHz switching frequency, it delivers dynamic motor responsiveness across packaging machinery, automotive manufacturing, textile equipment, and web tensioning systems.

Interface connections on the unit include dedicated Sub-D connectors for primary resolver feedback, a secondary encoder interface, six digital inputs, two digital outputs, and dual bipolar analog input and output channels. Built-in networking is provided through an integrated CANopen system bus operating up to 500 kbit/s, alongside a modular Automation Interface slot for optional fieldbus communication modules such as PROFIBUS-DP or INTERBUS. Replacing an existing drive requires transferring application parameters stored across four onboard EEPROM parameter sets. System settings can be configured and backed up using Global Drive Control software version 4.x or higher, or via the optional Keypad XT module. Support from ABC Industrial Parts is available to help source tested replacement units and facilitate parameter transfer.

Diagnostic feedback is delivered via two front-panel LED indicators and internal history logs C0168 and C0170, which record fault conditions for review through Global Drive Control diagnostic registers. Standard system warnings and fault conditions such as overvoltage, overcurrent, or resolver feedback loss can be resolved by checking supply wiring, motor insulation, and sensor connections. Internal hardware errors or EEPROM write failures indicate control board issues that cannot be repaired in the field, in which case ABC Industrial Parts can supply replacement drives or service options to restore plant operation.

Technical Specifications

ManufacturerLenze
Part Number13325140
Model / TypeEVS9327-ES
Product Family9300 Servo
Component TypeServo Drive
Rated Power11 kW
Supply Voltage3x 400 / 480 V AC
Supply Voltage Range320 - 528 V AC
Rated Output Current24 A
Maximum Output Current36 A
Control MethodField-oriented vector control
Switching Frequency8 kHz
Digital Inputs6
Digital Outputs2
Analog Inputs2
Analog Outputs2
Integrated Bus InterfaceCANopen
Protection RatingIP20

Programming and Configuration

The Lenze EVS9327-ES incorporates four non-volatile EEPROM parameter memory sets, allowing multiple machine operational profiles to be maintained onboard without risk of data loss during power outages. If parameter inconsistencies occur or an incomplete transfer triggers a P12 fault code, reloading a complete parameter file or restoring factory default settings restores normal operation.

Drive configuration and parameter management are supported through Lenze Global Drive Control (GDC) software version 4.x or higher. Through a direct serial or bus connection, engineers can manage drive settings, access diagnostic history logs C0168 and C0170, and monitor live control registers. Onsite manual parameter adjustments and dataset uploads can also be performed using the optional plug-in Keypad XT (EMF2171IB).

Communication and System Integration

Real-time system networking is provided via the drive's built-in CANopen system bus, which operates at data rates up to 500 kbit/s. To maintain reliable communication across the CAN network and prevent CE0 faults, the bus cable must be fitted with 120-ohm termination resistors at both physical endpoints and configured with matching baud rates across all connected nodes.

For integration into broader industrial networks, the EVS9327-ES features a plug-in Automation Interface (AIF) slot. This interface accepts option cards including PROFIBUS-DP modules (EMF2133IB and EMF2173IB), INTERBUS modules (EMF2102IB), and LECOM-B RS-485 modules. Physical control signals are handled through six digital inputs, two digital outputs, and dual bipolar analog input/output channels.

Diagnostics and Status Indication

Two front-panel LEDs provide immediate visual status monitoring for the drive. Status conditions can be cross-referenced with internal history registers C0168 and C0170 or monitored through GDC software to identify machine-level trips, supply drops, or control interlocks.

Status LED Indicators

LEDColor/StatusMeaning
DRIVE READYGreen - Solid / FlashingSolid = Drive in standard operation and ready; Flashing = Power section inhibited or initialization active.
DRIVE FAULTRed - Solid / FlashingSolid = Fault present and drive tripped; Flashing = Warning condition or threshold reached.

Replacement and Spare Part Considerations

Before installing a replacement Lenze EVS9327-ES, verify that the unit matches part number 13325140 to ensure correct rating alignment (11 kW rated output, 24 A continuous current). Confirm motor feedback wiring to connectors X6 and X8 for compatibility with Lenze 9300 series resolver-equipped servo motors.

A replacement drive must have its parameter settings restored from a valid Global Drive Control backup or transferred using a Keypad XT module prior to operation. Transfer any existing Automation Interface fieldbus modules (such as PROFIBUS-DP or INTERBUS) from the failed unit into the replacement drive's AIF option slot, making sure the module is fully seated.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short Circuit / Ground FaultInstantaneous overcurrent detection on motor phase outputs.Short circuit in motor cable, short circuit in motor windings, ground fault, or power stage transistor short.Check motor and output cabling for short circuit or ground connection; check motor insulation.
OC5I x t OverloadDrive overload during acceleration or high-torque operation.Excessive mechanical load, motor size too small, acceleration time set too short.Reduce mechanical load, increase acceleration time, check drive current sizing.
OHHeatsink OvertemperatureHeatsink temperature exceeded upper temperature limit (>85 °C).Inadequate cabinet ventilation, clogged heatsink cooling fins, ambient temperature too high, cooling fan defect.Clean heatsink, ensure adequate cooling/airflow in control cabinet, check internal fan operation.
OH4Motor OvertemperatureMotor thermal contact or PTC thermistor trip on terminal T1/T2.Motor thermal overload, insufficient motor cooling, defective thermal sensor circuit.Allow motor to cool down, check motor load, verify motor fan operation and PTC wiring.
OUDC Bus OvervoltageIntermediate DC bus voltage exceeded maximum allowable threshold (>770 V DC).Regenerative energy from motor during deceleration exceeds braking capacity; deceleration ramp too short; missing braking resistor.Increase deceleration ramp time; install or check external brake chopper / brake resistor.
LUDC Bus UndervoltageDC bus voltage fell below minimum allowable operating threshold.Mains supply failure, supply voltage drop, open phase in input line, defective input contactor.Check main AC line supply voltage and fuses; check input wiring and main contactor.
CE0CAN System Bus Communication FaultCommunication failure on integrated CAN system bus interface.Cable breakage, incorrect bus termination resistors, baud rate mismatch, excessive electrical noise.Inspect CAN cabling, verify 120 ohm termination resistors at both ends of bus, verify baud rate configuration.
CE1Automation Interface (AIF) FaultCommunication interruption between main board and plug-in AIF fieldbus module.Fieldbus communication error, module poorly seated in AIF slot, master controller off-line.Verify fieldbus cabling and master unit state; reseat plug-in AIF module in option slot.
EEEEPROM Memory ErrorInternal parameter memory checksum failure or EEPROM write error.Non-volatile memory corrupted, internal control board fault.Reload factory default settings and restore parameters. Internal hardware fault — if persistent, replace unit or contact service.
H10Internal Hardware Failure (Control Card)Hardware self-test failed on internal control unit.Internal electronic component failure on control processing board.Internal hardware failure — return unit for repair or replace servo drive.
H11Internal Hardware Failure (Power Section)Hardware fault detected in power section drive circuitry.Power circuit gate driver error, current sensor failure, or power module failure.Internal hardware failure — return unit for repair or replace servo drive.
NMAXSpeed Limit ExceededMotor feedback speed exceeded maximum allowed speed setting.Unstable velocity loop control, runaway motor load, incorrect encoder feedback scaling.Check motor encoder wiring and settings; re-tune speed controller gains.
Sd7Resolver / Encoder Feedback FaultSignal loss or broken wire detected on motor feedback connector (X6/X8).Resolver cable disconnected, broken wire in encoder harness, defective resolver or encoder sensor.Inspect resolver/encoder wiring and Sub-D plug connections; test feedback sensor.
P12Parameter Set FaultInconsistent or invalid parameter data stored in selected parameter set.Incomplete transfer of parameter set, incompatible parameter set version.Re-download complete parameter set from GDC or re-initialize parameter set to default.

Frequently Asked Questions

How are parameters transferred to a replacement Lenze EVS9327-ES drive?

Parameters can be saved and transferred using Lenze Global Drive Control (GDC) software version 4.x or higher connected to the drive interface, or uploaded directly at the drive using the optional Keypad XT (EMF2171IB) module. The unit maintains four non-volatile EEPROM memory locations for parameter sets.

Which motor feedback devices connect to the EVS9327-ES?

The drive features dedicated Sub-D connectors (X6/X8) for primary resolver feedback from Lenze 9300 series servo motors, along with a configurable secondary encoder input and output interface.

Which fieldbus expansion options can be installed on the drive?

In addition to the built-in CANopen system bus, the drive's Automation Interface (AIF) slot supports option modules including PROFIBUS-DP (EMF2133IB / EMF2173IB), INTERBUS (EMF2102IB), and LECOM-B (RS-485).

What causes an Sd7 feedback fault code on the drive?

An Sd7 fault indicates signal loss or a broken wire on the feedback connectors (X6/X8). Inspect the resolver cabling, Sub-D connector seating, and the resolver or encoder sensor on the motor.

What steps should be taken if the drive displays fault codes H10 or H11?

Fault codes H10 and H11 indicate internal hardware failures within the control card or power section circuitry. These conditions cannot be resolved by parameter resets in the field and require replacing the servo drive or sending the unit in for repair.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.