Product Information

Product Family: 8400 | Series: 8400 BaseLine

The Lenze 13468429, identified by model code E84AVBCE1522SX0XX3A34, is a compact 1.5 kW panel-mounted frequency inverter from the Lenze 8400 BaseLine series. Operating on a single-phase or three-phase 230 V AC supply at 50 Hz, this variable frequency drive delivers a rated output current of 7 A and output voltages up to 230 V AC for controlled AC motor applications. Designed for standard cabinet installation with an IP20 protection rating, the inverter integrates functional Safe Torque Off (STO) safety capabilities and onboard CANopen network connectivity, making it a reliable drive solution for conveyor systems, basic pump and fan flow control, and general material handling machinery.

Connecting and commissioning a replacement drive requires proper interface identification and parameter setup. The unit features four programmable digital inputs, one analog setpoint input, and a CANopen fieldbus port. Configuration and parameter management are supported using the local X400 Keypad or L-force EASY Starter commissioning software via an E84AYCER USB Diagnostic Adapter. Fast field replacement is made possible by the pluggable E84AYM01 memory module, which holds all drive configuration data and enables direct hardware swap without software tools. Technical support from ABC Industrial Parts can assist maintenance teams in sourcing units, migrating parameter settings, and verifying system compatibility.

Real-time operational monitoring and fault detection are handled through front-panel LED indicators and internal diagnostic logs. Indicators for RDY, ERR, CAN-RUN, and CAN-ERR provide immediate visual status of drive readiness, fault conditions, and fieldbus communication. Advanced diagnostic information is accessible via parameter C00168 diagnostic history log or the X400 keypad diagnostic display menu. Initial troubleshooting should verify incoming 230 V AC line supply, inspect output cabling for short circuits or insulation breakdown, and ensure adequate airflow around the heatsink. If unresolvable internal microcontroller hardware errors occur, obtaining a fully tested replacement drive through ABC Industrial Parts provides a fast route to restored operation.

Technical Specifications

ManufacturerLenze
Part Number13468429
Model / TypeE84AVBCE1522SX0XX3A34
Product Family8400
Series8400 BaseLine
Component TypeFrequency Inverter
Rated Power1.5 kW
Supply Voltage230 V AC
Supply Frequency50 Hz
Output Voltage230 V AC
Rated Output Current7 A
Maximum Output Frequency580 Hz
Switching Frequency8 kHz
IP RatingIP20
Mounting TypePanel mounting
Integrated FieldbusCANopen
Digital Inputs4 programmable inputs
Analog Inputs1 setpoint input
Safety FunctionIntegrated Safe Torque Off (STO)

Programming and Configuration

Parameter setup and commissioning of the Lenze E84AVBCE1522SX0XX3A34 inverter are performed through L-force EASY Starter commissioning software or directly at the cabinet using the plug-in Lenze X400 Keypad. Key operational settings include motor parameters, acceleration and deceleration ramps, switching frequency selection up to 8 kHz, and configuration of the 4 digital inputs and single analog setpoint input. Diagnostic parameter access and live tuning from a PC require an E84AYCER USB Diagnostic Adapter connected to the drive interface port.

All customer configurations and drive operational parameters are stored directly on the pluggable E84AYM01 memory module. When replacing a damaged or failed inverter in the field, this memory module can be removed from the original unit and plugged directly into the spare inverter. This hardware transfer preserves all exact parameter settings without requiring laptop connection, software reinstallation, or re-commissioning procedures.

Communication and System Integration

The Lenze 13468429 frequency inverter features an integrated CANopen interface for system bus integration. The CANopen connection facilitates fieldbus communication between the inverter and high-level controllers, enabling control commands, speed setpoints, and status feedback to pass across the network without extensive hardwiring.

Dedicated status LEDs on the front panel display active bus communications. The CAN-RUN LED indicates pre-operational and operational bus states, while the CAN-ERR LED highlights network communication failures or controller errors, simplifying network verification during initial commissioning and ongoing operation.

Diagnostics and Status Indication

Diagnostic inspection of the Lenze 8400 BaseLine inverter is achieved through four front-panel LEDs, live parameter views, diagnostic menus on the X400 Keypad, and L-force EASY Starter software. Operational history and past fault events are logged in parameter C00168, providing a recorded history for fault tracing.

The front panel includes four multi-state LED indicators that convey real-time operating conditions across the drive and fieldbus network.

Status LED Indicators

LEDColor/StatusMeaning
RDYGreen - Solid / FlashingGreen ON = Drive ready / active; Green flashing = Drive initialized / ready for operation
ERRRed - Solid / Flashing / OffRed ON = Fault active (drive inhibited); Red flashing = Warning active; OFF = No errors
CAN-RUNGreen - Solid / FlashingGreen ON = CANopen operational state; Flashing = Pre-operational
CAN-ERRRed - Solid / FlashingRed ON = CANopen bus off / error state; Flashing = Controller error

Replacement and Spare Part Considerations

When selecting a replacement for a Lenze 13468429 inverter, confirm that the model designation matches E84AVBCE1522SX0XX3A34. Key specifications that must align include the 1.5 kW power rating, 230 V AC input supply, 7 A rated output current, onboard CANopen connectivity, and built-in Safe Torque Off (STO) functionality.

Downtime during drive swapping can be minimized by transferring the original E84AYM01 memory module directly to the new unit. If future equipment updates or machine redesigns require a complete migration to current-generation drives, the Lenze i550 cabinet series is designated as the official successor line.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
0010Overvoltage DC Bus (OU)DC bus voltage exceeds upper threshold limit.Deceleration time too short, regenerative energy from motor too high.Extend deceleration ramp time (S-curve), install external braking option if applicable.
0020Undervoltage DC Bus (LU)DC bus voltage dropped below minimum operating limit.Mains supply voltage too low, supply phase loss, power interruption.Check input mains voltage and line fuses.
0030Motor Overload I2tThermal motor overload calculated via I2t monitoring.Continuous operation above rated motor current, mechanical overload.Check motor loading, mechanical system, and motor nameplate parameter settings.
0040Inverter Overload I2tThermal inverter overload calculated via internal monitoring.Inverter operated above rated continuous current for too long.Reduce motor load, extend acceleration ramps, check switching frequency setting.
0050Heatsink Overtemperature (OH)Heatsink temperature exceeds safe operating threshold.Inadequate ventilation, fan failure, ambient temperature too high, dirty heatsink fins.Clean heatsink cooling fins, ensure required clear space around drive, check cabinet cooling.
0070Short Circuit / Earth Fault (OC1)Excessive current detected at inverter output terminals.Short circuit in motor cable, short circuit in motor windings, earth/ground fault.Check motor and output motor cabling for short circuits and insulation faults to ground.
0080Mains Phase Failure (LP)Loss of a phase in mains input voltage.Blown input fuse, loose power wiring terminal, mains supply unbalance.Inspect line supply wiring, fuses, and incoming phase voltages.
0105Internal Hardware ErrorFatal internal micro-controller or board fault.Internal component failure, memory corruption.Internal hardware fault — return unit for repair or replace inverter.

Frequently Asked Questions

How can I transfer parameters to a new Lenze 13468429 inverter without software?

Parameters can be transferred by swapping the pluggable E84AYM01 memory module from the existing drive to the replacement unit. The memory module holds all stored configuration data, allowing hardware replacement without re-commissioning.

What software and interface adapter are used to commission model E84AVBCE1522SX0XX3A34?

This drive is commissioned using Lenze L-force EASY Starter software alongside an E84AYCER USB Diagnostic Adapter, or locally using an optional X400 Keypad.

What causes fault code 0010 on this inverter?

Fault code 0010 indicates DC bus overvoltage, caused by rapid motor deceleration or excessive regenerative power returning from the motor load. Extending the deceleration ramp time or adding a braking option resolves this fault.

What does a solid red ERR LED indicate on the front panel?

A solid red ERR LED indicates that an active fault has occurred and the drive output is inhibited. Specific error details can be identified via the X400 keypad, L-force EASY Starter, or fault history log parameter C00168.

What safety feature is integrated into the Lenze 8400 BaseLine drive?

The drive includes integrated Safe Torque Off (STO) functional safety, which safely interrupts power to the motor without needing external electromechanical safety contactors.

What is the recommended successor model for the Lenze 8400 BaseLine series?

The Lenze i550 cabinet series is the recommended successor line for legacy 8400 BaseLine frequency inverters.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.