Lenze 13564186 E82EV251_2C 8200 Vector Frequency Inverter 0.25 kW

New 
On request
Refurbished   
2 available for direct collection
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 Vector | Series: 8200 Vector

The Lenze 13564186, designated under model code E82EV251_2C, is a 0.25 kW frequency inverter from the 8200 Vector series designed for precise speed and torque regulation of standard three-phase AC motors. Operating from a supply voltage range of 180 V AC to 264 V AC, this unit delivers a continuous rated output current of 1.7 A at 230 V AC and supports output frequencies from 0 to 480 Hz. Built in a compact IP20 enclosure for standard control cabinet installation, it accommodates multiple motor control modes, including linear V/f, quadratic V/f, and sensorless vector control.

Putting a replacement drive into service requires parameter transfer, as a spare unit cannot operate a machine without proper configuration. Drive parameters can be cloned directly using the Keypad XT (E82ZBC) or transferred via Lenze Global Drive Control (GDC) software, utilizing internal non-volatile memory that stores up to four independent parameter sets. Network connectivity is achieved through a pluggable Function Module slot that accepts option cards such as the CANopen module (E82ZAFPC), PROFIBUS-DP module (E82ZAFDP), or LECOM RS-232/485 module (E82ZAFAL). ABC Industrial Parts can assist in sourcing replacement units and supporting configuration transfer to ensure minimum delay during commissioning.

Visual operational status is indicated on the drive by two front LEDs: a solid Red TRIP LED signaling an active fault where output is inhibited, and a Green LED indicating operational readiness and running status when lit or flashing. Detailed diagnostic information can be accessed through the keypad display, network status words, or the internal fault history register (C0168). Common operational events include overcurrent (OC1, OC2, OC5), DC bus overvoltage (OU), undervoltage (LU), and thermal overloads (OH, OH4). Hardware issues such as fault code H05 or unrecoverable memory errors (EE) represent internal failures that cannot be repaired in the field; in these cases, sending the module to ABC Industrial Parts for specialized repair or replacement with a tested exchange unit is the recommended solution.

Technical Specifications

ManufacturerLenze
Part Number13564186
Model / TypeE82EV251_2C
Product Family8200 Vector
Component TypeFrequency Inverter
Rated Power0.25 kW
Supply Voltage Range180 - 264 V AC
Rated Output Current1.7 A
Output Voltage230 V AC
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz
Control MethodV/f linear, V/f quadratic, sensorless vector control
Enclosure RatingIP20

Programming and Configuration

Programming and parameter management for the Lenze E82EV251_2C are conducted using Lenze Global Drive Control (GDC) software or directly via the optional Keypad XT (E82ZBC). The inverter incorporates integrated non-volatile memory capable of retaining up to four distinct parameter configurations, allowing flexible machine setup across different operational profiles.

When installing a spare drive, parameter cloning via the Keypad XT allows all configuration parameters to be copied directly from the original inverter without manual data entry. Alternatively, parameters can be loaded electronically from a backup file using GDC software. In the event of parameter corruption, restoring default operational parameters is accomplished by executing code C0002.

Communication and System Integration

The modular architecture of the Lenze 8200 Vector drive utilizes a front-mounted Function Module slot for fieldbus integration. This design allows the base inverter to connect to standard control networks without altering the power section.

Supported communication cards include the CANopen Module (E82ZAFPC), PROFIBUS-DP Module (E82ZAFDP), and LECOM RS-232/485 Module (E82ZAFAL). Through these interfaces, higher-level controllers can issue run commands, update speed references, and continuously monitor internal status words across the network.

Diagnostics and Status Indication

Operational health is monitored through front-panel visual indicators and internal software registers. A solid Red TRIP LED indicates an active drive fault and output inhibition, while the Green LED provides real-time operational status by lighting continuously or flashing during active drive operation.

Advanced diagnostic inspection can be performed by reading error messages on the Keypad XT display, querying the status word via network communication, or reviewing historic trip events saved in fault history register C0168.

Status LED Indicators

LEDColor/StatusMeaning
Red LED (TRIP)Red - SolidActive TRIP fault state present; drive is inhibited.
Green LED (Ready/Operation)Green - Solid/FlashingDrive operational readiness / run status when lit or blinking.

Replacement and Spare Part Considerations

Replacing a Lenze 13564186 E82EV251_2C frequency inverter requires matching the physical power rating (0.25 kW) and correctly transferring installed hardware accessories. The communication Function Module plugged into the front of the original inverter (such as PROFIBUS, CANopen, or LECOM) must be removed and installed into the replacement unit to maintain fieldbus connectivity.

Because a replacement unit contains factory or blank parameter settings, operating parameters must be transferred from the original unit prior to starting the machine. This can be accomplished by cloning parameters via the Keypad XT module (E82ZBC) or downloading the saved application file using Global Drive Control (GDC) software.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuit / Earth faultOvercurrent during acceleration or short circuit on motor terminals.Short circuit in motor cable or motor winding; earth fault; acceleration time set too short.Check motor and motor cable for short circuit/earth fault; increase acceleration time; check drive sizing.
OC2Overcurrent during decelerationOvercurrent condition during deceleration phase.Deceleration time set too short; braking module/resistor non-functional or missing.Increase deceleration time; fit braking module/resistor if required.
OC5Overcurrent during steady operationOvercurrent during steady-state constant speed operation.Abrupt load changes; motor overload; mechanical blockage.Check mechanical load and drive capacity; clear mechanical blockages.
OUOvervoltage DC busDC bus voltage exceeded maximum limit.Regenerative energy from motor during deceleration; excessive supply voltage.Increase deceleration time; check supply voltage; install braking resistor/module.
LUUndervoltage DC busDC bus voltage fell below minimum operating threshold.Mains supply voltage too low or interrupted; mains phase failure; supply drop under load.Check mains voltage; check input wiring and fuses.
OHHeatsink temperature highInverter heatsink temperature exceeded warning limit.Inadequate cooling; ambient temperature too high; clogged cooling fins or fan failure.Clean cooling fins; verify enclosure ventilation; reduce switching frequency or load.
OH4Motor thermal overload (PTC)Motor temperature sensor triggered overtemperature TRIP.Motor thermal overload; PTC sensor wire break or high resistance.Allow motor to cool; check motor loading; check PTC sensor connection.
EEEEPROM memory faultInternal EEPROM checksum error or corrupted parameters.Power failure during parameter write operation; hardware memory failure.Reload factory defaults (C0002); if error persists, internal hardware fault — return unit for repair.
H05Internal hardware faultHardware fault detected on internal control board or power stage.Internal component failure or power section fault.Internal hardware fault — unit is not field-serviceable; return unit for repair or replace.
EErExternal TRIP signalTRIP triggered via digital input configured for external error.External monitoring device (e.g. thermal relay, external interlock) tripped.Inspect external system connected to external fault input.
LP1Motor phase failureMotor output phase loss detected.Interrupted cable between drive and motor; motor winding open circuit.Check motor connections, cables, and motor windings.
NMAXSpeed threshold exceededActual motor speed exceeded maximum allowable speed setting.Incorrect slip compensation setting or overspeed driven by external load.Check motor parameters, slip compensation, and mechanical load.

Frequently Asked Questions

How do I transfer parameters to a replacement Lenze E82EV251_2C drive?

Drive parameters can be cloned directly using the Keypad XT (E82ZBC) module by copying the active parameter set from the original unit and pasting it to the spare inverter. Alternatively, parameters can be loaded via computer using Lenze Global Drive Control (GDC) software.

What fieldbus communication modules are supported by the 13564186 inverter?

The E82EV251_2C features a pluggable Function Module slot that accepts option cards including CANopen (E82ZAFPC), PROFIBUS-DP (E82ZAFDP), and LECOM RS-232/485 (E82ZAFAL).

What does a solid red TRIP LED indicate on the inverter?

A solid Red TRIP LED indicates an active fault condition that has inhibited the drive output. Troubleshooting should be performed using the keypad error display or fault history register C0168 before resetting.

How can an EE fault code be cleared?

An EE fault indicates memory corruption in the internal EEPROM. Reset the drive to factory defaults using parameter C0002. If the fault persists after reloading default settings, the drive has suffered internal hardware damage and must be repaired.

Is the Lenze H05 fault code field-serviceable?

No. The H05 fault code indicates an internal hardware failure on the power stage or control board. The unit is not field-serviceable and must be repaired or replaced with a tested exchange unit.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.