Product Family: 9400 HighLine | Series: 9400 HighLine

The Lenze 15135540 (type E94ASHE0024A22ENNN) is a single-axis servo drive in the Lenze 9400 HighLine family designed for high-precision positioning and multi-axis motion control. Operating on a nominal 3-phase 400/480 V AC supply across a 320 to 528 V AC range, this panel-mounted servo drive delivers a rated output power of 0.75 kW with a continuous current rating of 2.5 A and a peak current capability of 5 A at a 4 kHz switching frequency. To ensure functional safety without additional panel contactors, the unit integrates a Safe Torque Off (STO) module alongside an onboard brake chopper to absorb regenerative energy in dynamic packaging, automated handling, or textile processing machinery.

Integrating a replacement drive into an existing control system relies on matching both fieldbus interfaces and parameter code. The E94ASHE0024A22ENNN provides standard onboard CANopen connectivity over dual RJ45 connectors, supplemented by multi-encoder feedback terminals supporting resolvers, SinCos, Hiperface, EnDat, SSI, TTL, and HTL encoder systems. Two option slots accept modular communication hardware such as the E94AYCER PROFINET, E94AYCET EtherCAT, E94AYCPM PROFIBUS-DP, or E94AYCEO EtherNet/IP interface cards. Putting a spare unit into operation can be completed without a PC or software tools by transferring the removable MM200 or MM300 memory module from the original drive, which holds all drive parameters, application code, and firmware settings. ABC Industrial Parts can assist maintenance teams with spare unit preparation, fieldbus option selection, and hardware verification.

Real-time monitoring and fault isolation are managed through front-panel LEDs and onboard software diagnostics. Status indicators include DRV-RDY for drive readiness, DRV-ERR for fault conditions, CAN RUN for system bus status, and CAN ERR for bus errors or parameter mismatches. Diagnostic data is also captured within a logbook on the memory module and accessible through the E94AZKCE keypad, E94AZCUS USB adapter, or L-force Engineer and EASY Starter software. Common field issues include mains undervoltage, motor earth faults, feedback cable disconnection, or STO input discrepancies. If the DRV-ERR LED remains solid red or code 0x0020 occurs after a full power reset, an internal hardware failure has occurred that is not field-serviceable, requiring drive repair or replacement through ABC Industrial Parts.

Technical Specifications

Rated Power0.75 kW
Rated Current2.5 A
Peak Output Current5 A
Nominal Supply Voltage3x 400/480 V AC
Operational Voltage Range320 - 528 V AC
Switching Frequency4 kHz
Onboard FieldbusCANopen
Encoder FeedbackResolver, Multi-Encoder (SinCos, Hiperface, SSI, TTL, HTL, EnDat)
Mounting TypePanel Mount
Integrated SafetySafe Torque Off (STO)

Programming and Configuration

Drive commissioning, parameter adjustments, and program development for the Lenze 15135540 E94ASHE0024A22ENNN servo drive are managed through the Lenze L-force Engineer and EASY Starter software suites. Connecting a PC to the drive for real-time monitoring and parameter transfer can be accomplished using the E94AZCUS USB diagnostic adapter or via an attached fieldbus network. Handheld local configuration is also supported using the pluggable E94AZKCE keypad.

Rapid unit replacement without software tools is enabled by the removable MM200 or MM300 memory module. All operational parameters, customer application programs, and firmware configurations reside on this memory card. Transferring an existing card to a replacement drive restores identical operating parameters and network node configurations immediately upon power-up.

Communication and System Integration

The Lenze 15135540 features standard onboard CANopen system bus capability accessed through dual RJ45 ports, allowing multi-axis bus synchronization and real-time motion control integration. Bus status is monitored directly via dedicated CAN RUN and CAN ERR status indicators on the front panel.

For broader control architecture integration, the 9400 HighLine drive includes two modular option slots. These slots accommodate fieldbus expansion modules including E94AYCER for PROFINET, E94AYCET for EtherCAT, E94AYCPM for PROFIBUS-DP, and E94AYCEO for EtherNet/IP. Universal encoder inputs handle feedback signals from resolvers, SinCos, Hiperface, SSI, EnDat, TTL, and HTL feedback units.

Diagnostics and Status Indication

Diagnostic feedback for the E94ASHE0024A22ENNN drive is provided via visual indicators, software diagnostic mapping, and an internal diagnostic logbook recorded on the plug-in memory card. Technicians can view system state information using the E94AZKCE handheld keypad display, L-force Engineer, or EASY Starter software.

Status LED Indicators

LEDColor/StatusMeaning
DRV-RDYGreen - Solid / FlashingGreen: Controller is ready for operation. Flashing: Initialization active or waiting for enable.
DRV-ERRRed - Solid / FlashingRed solid/flashing: Active fault or error condition. Internal hardware fault if persistent after power reset.
CAN RUNGreen - SolidCANopen system bus operational.
CAN ERRRed - Solid / FlashingCANopen bus error or configuration mismatch.

Replacement and Spare Part Considerations

Replacing a Lenze 15135540 9400 HighLine drive requires matching the hardware model number E94ASHE0024A22ENNN to ensure equivalent 0.75 kW power ratings, continuous 2.5 A current limits, and integrated STO functional safety capabilities. Verify that installed communication options—such as PROFINET or EtherCAT modules—are moved to the replacement drive's expansion slots prior to mounting.

Drive commissioning during unit replacement is streamlined by moving the MM200 or MM300 memory module from the original drive directly into the spare unit. This transfers all stored motion parameters, safety configurations, and network addresses without requiring a PC connection. Before placing the machine back into service, check line voltage supplies, motor encoder cabling, and safety circuit signals to verify proper operating conditions.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
0x0001Earth fault / Short circuitShort circuit or ground fault detected at motor terminalsMotor winding failure, damaged motor cable, or internal power section short circuitCheck motor wiring and insulation. If fault persists with motor disconnected, internal hardware fault — replace or repair unit.
0x0002DC bus overvoltageDC bus voltage exceeded upper safety thresholdBraking energy too high, brake chopper resistor disconnected or defective, deceleration ramp too shortCheck brake resistor connection and value, extend deceleration time, or check mains supply voltage.
0x0003DC bus undervoltageDC bus voltage fell below lower operational thresholdMains supply power failure, blown line fuse, line phase loss, or main contactor openVerify line input voltage across all phases and check fuses and supply line contactors.
0x0004Motor overtemperatureMotor temperature sensor threshold exceeded (i2t or thermal sensor)Motor overload, mechanical blockage, defective cooling fan, incorrect sensor parameterizationCheck motor mechanical load, cooling flow, sensor wiring, and thermal motor limits in parameters.
0x0005Heatsink overtemperaturePower section heatsink temperature limit exceededInadequate cabinet ventilation, clogged heatsink cooling fins, internal fan failure, ambient temp too highClean heatsink fins, verify cabinet fan operation and ambient airflow.
0x0006Internal temperature highDrive internal control unit temperature limit exceededControl section ambient temperature exceeds limits, cabinet cooling insufficientCheck electrical cabinet cooling performance.
0x0007Motor phase failureOutput phase interruption detectedLoose motor wire, damaged motor cable, open motor windingInspect motor cabling and terminal tightness.
0x0008Mains phase failureOne line input phase missing or line unbalance too highBlown input fuse, loose line connection, supply line phase lossMeasure input phase-to-phase voltages under load.
0x0012Encoder feedback faultResolver or encoder signal fault / communication timeoutDamaged encoder cable, loose D-sub connector, missing shield grounding, defective encoderCheck encoder wiring, shield connection, and test encoder hardware.
0x0020Internal system faultInternal micro-controller hardware failure or firmware watchdog tripInternal memory corruption, ASIC or board component failureInternal hardware failure — power cycle unit; if error persists, return unit for repair or replace.
0x0050Safe Torque Off (STO) faultSafety circuit condition fault or channel discrepancy detectedDiscrepancy between safety input channel 1 and channel 2, damaged STO wiringVerify STO input dual-channel signals and reset safety circuit.

Frequently Asked Questions

How do you replace a Lenze 15135540 drive without using software?

Transfer the MM200 or MM300 memory module from the existing unit to the replacement drive. The card contains all parameters, application code, and firmware settings, allowing plug-and-play commissioning without a PC.

What fieldbus networks are supported by the E94ASHE0024A22ENNN?

Onboard CANopen is supported natively via dual RJ45 connectors. Expansion modules can be added for PROFINET (E94AYCER), EtherCAT (E94AYCET), PROFIBUS-DP (E94AYCPM), and EtherNet/IP (E94AYCEO).

Which motor encoder types can be connected to this servo drive?

The drive features multi-encoder support compatible with resolvers, SinCos, Hiperface, EnDat, SSI, TTL, and HTL encoder feedback devices.

What does a solid red DRV-ERR LED indicate on the Lenze 9400 drive?

A solid red DRV-ERR LED signals an active fault condition. If the indicator remains red after cycling control power, an internal hardware fault has occurred that requires unit repair or replacement.

What causes fault code 0x0001 on the Lenze 15135540 drive?

Fault code 0x0001 indicates an earth fault or short circuit at the motor terminals, caused by damaged motor wiring, winding failure, or internal power component short circuits.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.