Lenze 324515 765-E36 Handheld Operating Terminal

New 
On request
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

The Lenze 324515 (Model 765-E36) is a portable handheld operating terminal engineered for standalone parameterization, operation, and monitoring of Lenze drive systems. Belonging to the 765 Series Operating Terminals, this compact keypad unit features an illuminated 2-line by 16-character LCD display and an IP20 rated enclosure, eliminating the requirement for a laptop or dedicated engineering software during field service. Designed specifically for legacy industrial automation environments, the terminal is compatible with Lenze 8100 Series Frequency Inverters, Lenze 8200 Series Frequency Inverters, and Lenze 5300 Series Drive Controllers. Power is delivered directly via a 5 V DC bus connection from the host inverter's diagnostic port, removing the need for internal batteries or external power adapters.

Physical connection to host drive controllers is established through an integrated 9-pin male Sub-D RS232 serial interface communicating via the native Lenze System Bus Protocol. A primary functional feature of the 765-E36 is its integrated non-volatile EEPROM memory, which holds one complete parameter set. Service personnel can back up drive parameters directly onto the keypad, transfer the terminal to a replacement drive controller, and upload the saved settings in seconds. When replacing a failed terminal or commissioning a replacement drive, obtaining parameter backup and hardware support through ABC Industrial Parts helps minimize downtime during equipment overhauls.

Diagnostic routines and operational monitoring are executed directly through the illuminated display, which presents live operational metrics such as output frequency, motor current, DC-bus voltage, and drive state. Technicians can also inspect the internal history buffer to examine logged fault messages and drive trips directly at the machine panel. If serial signal degradation or improper cabling occurs, the terminal displays explicit communication alarms on screen. When internal component faults or physical connector damage occur on host or terminal ports, sourcing a tested replacement unit or repair through ABC Industrial Parts provides a fast route back to production.

Technical Specifications

ManufacturerLenze
Part Number324515
Model/Type765-E36
Component TypeHandheld Operating Terminal
Product Family765 Series Operating Terminals
Supply Voltage5 V DC
Display TypeIlluminated LCD
Display Resolution2 lines x 16 characters
Configuration MemoryInternal Non-Volatile EEPROM (1 Parameter Set)
Serial Interface PortRS232 (9-pin Sub-D Male)
Communication ProtocolLenze System Bus Protocol
Ingress Protection RatingIP20

Programming and Configuration

The 765-E36 handheld operating terminal provides comprehensive on-site drive parameterization and tuning without requiring a PC or external software cables. Operating personnel can adjust drive parameters, tune motor control loops, and modify operational settings directly using the integrated keypad and 2-line by 16-character illuminated LCD.

For rapid drive duplication and spare replacement routines, the terminal incorporates an internal non-volatile EEPROM memory module capable of storing one full parameter set. Service personnel can extract an existing parameter profile from a running drive into the keypad memory, connect the unit to a new drive, and write the stored profile directly to memory, eliminating manual parameter re-entry.

Communication and System Integration

The Lenze 324515 (765-E36) unit connects directly to drive controllers via a built-in 9-pin male Sub-D RS232 serial interface port. Standard data exchange utilizes Lenze System Bus Protocol to ensure real-time point-to-point parameter transfer and telemetry readout.

Operating power is drawn directly through the host drive's serial diagnostic port at 5 V DC. Because communication and power delivery share the serial interface line, no external power cables, secondary power supplies, or internal batteries are required during panel or field operation.

Diagnostics and Status Indication

Live parameter monitoring is performed directly on the backlit LCD screen. The terminal provides continuous real-time readout of crucial operating variables, including actual output frequency, motor current, DC-bus voltage, and current drive state.

Fault diagnostic capabilities include real-time fault code display and readout of an internal history buffer. Maintenance technicians can access logged fault history directly on the machine floor to troubleshoot intermittent drive trips and verify operating history.

Replacement and Spare Part Considerations

When selecting a replacement terminal, verify that the 324515 part number and 765-E36 model designation match the original unit. Ensure compatibility with host drive families, which include Lenze 8100, Lenze 8200, and Lenze 5300 series controllers.

Before replacing a faulty inverter, utilize the 765-E36 terminal to backup the existing drive parameter set to the internal EEPROM. Once the replacement inverter is physically installed and energized, download the saved parameter set to restore complete machine functionality immediately.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
COMM ERRORCommunication ErrorSerial communication timeout or failure between 765-E36 operating unit and frequency inverter.Damaged interface cable, wrong baud rate setting, defective serial port on inverter, loose connector, or inverter powered off.Check cable connection, verify power to frequency inverter, inspect SUB-D pins for damage.

Frequently Asked Questions

Which drive controllers are compatible with the Lenze 324515 765-E36 terminal?

The Lenze 324515 (765-E36) handheld terminal is compatible with Lenze 8100 Series Frequency Inverters, Lenze 8200 Series Frequency Inverters, and Lenze 5300 Series Drive Controllers.

Does the Lenze 765-E36 operating terminal require batteries or external power?

No external power supply or internal battery is required. The terminal receives its 5 V DC operating power directly from the host inverter through the 9-pin Sub-D RS232 connection.

How does parameter copying work on the 765-E36 keypad?

The unit features internal non-volatile EEPROM memory that stores one parameter set. Service personnel can upload settings from an operational drive, move the terminal to a replacement drive, and transfer the configuration directly.

What causes a COMM ERROR message on the 765-E36 display?

A COMM ERROR indicates a serial communication failure between the terminal and inverter. Typical causes include loose connectors, damaged 9-pin Sub-D pins, unpowered inverters, or incorrect baud rate settings.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.