Lenze 339405 8606_E.1B.11 Systembus CAN Communication Module

New 
On request
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: Systembus Modules

The Lenze 339405 is a 8606_E.1B.11 Systembus communication module designed to enable high-speed CAN-based networking across industrial drive systems. Operating on the ISO 11898 CAN physical layer, this module integrates into Lenze 8600 series frequency inverters and Lenze 2100 series servo drives to establish masterless, peer-to-peer data interchange between drives and controllers. The unit installs directly into the host drive function interface (FIF / Automation Slot), receiving its required 5 V DC operational power internally through the slot interface without external power wiring. Physical connection to the network is accomplished via plug-in terminal blocks or Sub-D socket connectors.

Putting a replacement 339405 module into service requires setting the hardware configuration to match the original network node. Hardware DIP switches located on the module are used to set the node address and transmission speed within a range of 20 kbit/s to 500 kbit/s prior to installation. Proper integration into the host drive system involves checking watchdog monitoring parameters and bus timing using Lenze Global Drive Control (GDC) software or a Lenze XT keypad module. When replacing a failed communication card, matching DIP switch configurations allows ABC Industrial Parts to supply ready-to-integrate replacement units that restore fieldbus communications promptly.

Diagnostic feedback is provided on the front panel by RUN (green) and ERR (red) LED indicators. A solid green RUN LED confirms active, correct communication on the Systembus, while a solid or flashing red ERR LED points to network issues such as bus-off conditions, wiring errors, baud rate mismatches, or collisions. In addition to visual indications, the host drive records specific CAN monitoring fault codes ranging from CE0 for bus-off events to CE1 through CE4 for process data watchdog timeouts. Standard field maintenance includes checking cable integrity, shield grounding, and line termination resistors (120 Ohm). If an ERR LED remains continuously illuminated without network traffic, internal hardware faults may be present, where fully tested replacement or repair units from ABC Industrial Parts provide a swift path back to operational capability.

Technical Specifications

ManufacturerLenze
Part number339405
Model / Type8606_E.1B.11
Component typeCommunication Module
Product familySystembus Modules
Supply voltage5 V DC (internal host slot power)
Bus systemLenze Systembus (CAN ISO 11898)
Baud rate range20 - 500 kbit/s
Interface connectorPlug-in terminal block / Sub-D socket
Mounting typePlug-in module (FIF / Automation Slot)
Lifecycle statusDiscontinued (Successor: EMF2171IB)

Programming and Configuration

Configuration of the Lenze 339405 (8606_E.1B.11) module is handled through a combination of physical hardware switches and software tools. Onboard hardware DIP switches allow engineers and technicians to assign the node ID and establish the transmission rate between 20 kbit/s and 500 kbit/s prior to powering up the module. Hardware settings must be configured correctly before inserting the module into the host drive's function interface slot to prevent network communication errors.

Software-based parameter management and advanced diagnostic monitoring are conducted using Lenze Global Drive Control (GDC) software or a host drive mounted Lenze XT keypad. Through these interfaces, engineers can adjust Systembus monitoring parameters, set watchdog timeouts, and monitor process data objects (CAN-IN1 through CAN-IN4). Proper synchronization between the host drive's internal settings and the module's DIP switch setup ensures reliable data exchange across the fieldbus network.

Communication and System Integration

The 339405 Systembus module operates on the ISO 11898 CAN physical layer standard, enabling masterless peer-to-peer data exchange across Lenze frequency inverters and servo controllers. By allowing direct drive-to-drive speed and torque synchronization without relying on a central master PLC, the module significantly reduces network overhead and control system latency. Physical fieldbus connections are terminated using plug-in terminal blocks or Sub-D socket connectors.

System integration requires adherence to standard CAN bus architecture, including proper shield grounding and correct network termination. A 120 Ohm terminating resistor must be installed at both physical ends of the Systembus network line to maintain signal integrity and prevent bus reflection errors. The module supports flexible baud rates ranging from 20 kbit/s up to 500 kbit/s, which must be uniformly configured across all connected nodes on the bus segment.

Diagnostics and Status Indication

Visual monitoring of the 339405 communication module is performed via two integrated LED indicators labeled RUN and ERR. The green RUN LED illuminates continuously when Systembus operation is active and telegrams are transmitting correctly. Conversely, the red ERR LED indicates communication disturbances, including bus-off states, wiring errors, baud rate mismatches, or bus collisions. If the red ERR LED stays continuously lit in the absence of bus activity, an internal hardware fault is indicated.

Extended diagnostic monitoring is accessible directly through the host drive using a Lenze XT keypad or via Lenze Global Drive Control (GDC) software. Systembus diagnostic registers maintain error counters and report specific fault states, enabling technicians to pinpoint connection losses or watchdog timeout conditions across individual process data objects.

Status LED Indicators

LEDColor/StatusMeaning
RUN / Green LEDGreen - Solid / ActiveSystembus operation active; communication running correctly.
ERR / Red LEDRed - Solid / FlashingSystembus fault present (bus-off condition, wiring error, baud rate mismatch, or collision). Hardware fault if LED remains continuously red without bus traffic.

Replacement and Spare Part Considerations

The Lenze 339405 (8606_E.1B.11) Systembus module has reached discontinued status by the manufacturer. While it remains vital for maintaining existing machinery operating with Lenze 8600 series inverters and 2100 series servo drives, direct replacement requires careful verification of node addresses and baud rate settings on the onboard DIP switches prior to installation into the host FIF slot.

When replacing a faulty module, match all hardware DIP switch settings to the existing unit to maintain network parity. Verify that the bus termination resistors (120 Ohm) are intact at the end nodes of the segment. For new system designs or extensive retrofits, the EMF2171IB serves as the manufacturer's recommended functional successor series.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
CE0CAN Communication Error / Bus OffSystembus CAN module detected severe bus communication disturbance or bus-off state.Incorrect baud rate, defective cable/shielding, missing terminating resistor, excessive bus load.Check CAN wiring, shield grounding, termination resistors (120 Ohm), and node baud rate settings.
CE1Systembus Monitoring Timeout (CAN-IN1)Process data object 1 was not received within the configured watchdog monitoring time.Transmitting node stopped sending, network interruption, node failure.Check transmitting node state, cable integrity, and monitoring time parameter settings.
CE2Systembus Monitoring Timeout (CAN-IN2)Process data object 2 was not received within the configured watchdog time.Transmitting node timeout, connection lost.Verify transmitter node status and network connection.
CE3Systembus Monitoring Timeout (CAN-IN3)Process data object 3 was not received within the configured watchdog time.Transmitting node timeout, CAN frame lost.Verify transmitter node status and communication load.
CE4Systembus Monitoring Timeout (CAN-IN4)Process data object 4 was not received within the configured watchdog time.Transmitting node timeout.Verify transmitter node status and fieldbus network health.

Frequently Asked Questions

How is the node address and transmission speed configured on the Lenze 339405 module?

Hardware DIP switches located directly on the 339405 module are used to set the node address and baud rate between 20 kbit/s and 500 kbit/s prior to inserting the module into the host drive slot.

What does a red ERR LED indicate on the Lenze 339405 Systembus module?

A solid or flashing red ERR LED indicates a Systembus fault, such as a bus-off condition, wiring error, baud rate mismatch, missing termination resistor, or collision. If it stays red without network activity, a hardware fault is indicated.

How is the Lenze 339405 module powered?

The module receives 5 V DC power directly from the host Lenze drive through the function interface slot (FIF / Automation Slot), requiring no external power supply wiring.

What software can be used to diagnose communication issues with the 339405 module?

Diagnostic data and watchdog monitoring settings can be accessed using Lenze Global Drive Control (GDC) software or directly on the host drive using a Lenze XT keypad.

What are the primary causes for fault code CE0 on this module?

Fault code CE0 indicates a CAN Communication Error or Bus Off state caused by incorrect baud rates, damaged cabling or shielding, missing 120 Ohm termination resistors, or high bus load.

What is the recommended successor model for the discontinued 339405 module?

The manufacturer designates the EMF2171IB series as the recommended functional successor for new implementations or system upgrades.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.