Product Information

Product Family: Lenze 8100 | Series: 8100

The Lenze 8102_E.4G.12 is a 0.75 kW frequency inverter from the Lenze 8100 series, engineered to provide precise variable speed control for standard 3-phase AC induction motors. Designated under model type 8102 E, this compact drive operates across a 3-phase supply voltage range of 320 V AC to 528 V AC (400 V nominal) and delivers a continuous output current of 2.5 A. With an adjustable output frequency from 0 Hz to 480 Hz, it is suited for conveyor systems, material handling drive axes, centrifugal pumps, and industrial fan regulation. Physical connectivity is handled via integrated screw control terminals for digital, analog, and relay contact interfaces, alongside a front option slot for add-on modules.

Integrating a replacement drive into an existing automation line requires matching terminal layouts, verifying fieldbus interfaces, and configuring drive parameters. The Lenze 8102_E.4G.12 supports modular communication via optional LECOM RS-232/RS-485 or CAN system bus modules inserted into the front slot. Commissioning a spare unit is not a simple plug-and-run procedure; parameter sets must be transferred to the replacement unit using either a plug-in keypad module or Lenze Global Drive Control (GDC) PC software. When parameter extraction from a faulty donor unit is challenging, technical assistance from ABC Industrial Parts can support configuration recovery and spare unit preparation.

Real-time monitoring and fault identification are facilitated through the optional plug-in operating keypad display, parameter C003 in GDC software, or the physical status relay output. The inverter actively monitors operating conditions and triggers distinct fault codes for overcurrent events, DC bus overvoltage or undervoltage, phase loss, and motor or heatsink thermal limits. While field-level checks can resolve external line voltage or wiring errors, internal hardware issues such as memory errors or output stage breakdown cannot be repaired on-site. In these cases, procuring a tested exchange unit or utilizing repair services from ABC Industrial Parts offers a dependable path back to full production.

Technical Specifications

ManufacturerLenze
Part Number8102_E.4G.12
Model / Type8102 E
Product FamilyLenze 8100
Component TypeFrequency Inverter
Rated Power0.75 kW
Nominal Supply Voltage400 V AC (3-Phase)
Supply Voltage Range320–528 V AC
Continuous Output Current2.5 A
Output Frequency Range0–480 Hz
Control ConnectionIntegrated Screw Terminals
Module SlotFront Slot for Keypad / LECOM / CANopen Modules

Programming and Configuration

Drive configuration for the Lenze 8102_E.4G.12 is performed using Lenze Global Drive Control (GDC) PC software or directly via a plug-in operating module keypad. Parameterization includes setting acceleration and deceleration times, motor thermal protection limits, and terminal mapping for analog and digital I/O.

For rapid maintenance turnover, parameter sets can be cloned directly between drives using the plug-in keypad module or exported and reloaded using GDC software. In the event of EEPROM parameter corruption (fault code EE), executing a factory reset restores default parameters, allowing full re-commissioning of the unit.

Communication and System Integration

The Lenze 8102_E.4G.12 integrates into distributed control networks through dedicated communication interface modules fitted into its front panel slot.

Available module options include Lenze LECOM modules supporting RS-232 or RS-485 serial communications and Lenze CAN system bus modules. Correct protocol setup, address selection, and matching baud rates are required to maintain continuous data exchange and prevent communication timeout faults.

Diagnostics and Status Indication

Diagnostic indications on the Lenze 8102_E.4G.12 are provided locally via the plug-in operating module keypad display, through parameter C003 in GDC software, and via the hardwired status relay contact output.

The inverter continuously performs self-diagnostic routines to protect against overcurrent, internal ground faults, DC bus voltage fluctuations, phase loss, and overtemperature conditions, giving maintenance teams precise fault indications during operational interruptions.

Status LED Indicators

LEDColor/StatusMeaning
Ready / FaultGreen / Red - Solid / FlashingOperating status and fault indicators on optional plug-in operating panel

Replacement and Spare Part Considerations

Before installing a spare Lenze 8102_E.4G.12 inverter, ensure that the power rating (0.75 kW, 2.5 A) and voltage supply match the existing installation. Because drive behavior relies on application-specific parameter settings, running a spare drive requires copying the parameter set from the original unit prior to startup.

Parameter transfer can be accomplished via the plug-in keypad module or GDC software. If complete line modernizations are planned, Lenze 8400 or i500 series inverters serve as modern replacement alternatives for long-term upgrades.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Overcurrent during accelerationOutput current exceeded overcurrent threshold during acceleration rampAcceleration time too short, motor overload, short circuit in motor cable, incorrect motor parametersIncrease acceleration time, check motor wiring for short circuits, verify motor parameter configuration
OC2Overcurrent during decelerationOutput current exceeded overcurrent threshold during deceleration rampDeceleration time too short, generatoric overload, braking chopper faultIncrease deceleration time, install or check external braking resistor, check motor insulation
OC3Overcurrent at constant speedOutput current exceeded overcurrent threshold during steady-state operationSudden load change, motor stalled, short circuit or ground faultCheck mechanical load for jam, inspect motor cables and terminal connections
OC5Earth fault / Short circuitGround fault or phase-to-phase short circuit detected at inverter outputMotor cable insulation breakdown, ground fault in motor windings, defective output power stageDisconnect motor cables and measure insulation resistance. If fault persists with cables disconnected, internal hardware fault — return unit for repair.
OUOvervoltage DC busDC bus voltage exceeded maximum allowable thresholdMains supply voltage too high, regenerative energy during braking too high without active braking moduleCheck supply voltage, extend deceleration time, connect external brake resistor
LUUndervoltage DC busDC bus voltage dropped below minimum operating limitMains supply voltage too low, supply phase loss, power supply interruptionCheck mains voltage and supply line fuses
OHHeatsink overtemperatureInverter heatsink temperature exceeded maximum operating thresholdInadequate cooling / ventilation, ambient temperature too high, fan failure, dirty heatsinkClean cooling fins, verify cabinet ventilation and fan operation, allow drive to cool down
OH4Motor overtemperatureMotor temperature sensor (PTC/TK) detected thermal overloadMotor continuous overload, insufficient motor cooling, defective sensor wireReduce motor load, inspect motor cooling fan and thermal contact wiring
LP1Mains phase failurePhase loss detected on incoming AC mains supplyBlown input fuse, loose connection on line terminal, line voltage unbalanceCheck incoming power mains lines, fuses, and terminal block connections
EEEEPROM memory errorChecksum fault or corruption in internal EEPROM parameter storageElectromagnetic interference during write process, corrupted memory hardwarePerform factory parameter reset (load default settings) and re-commission drive. Internal hardware fault if error cannot be reset — return unit for repair.
EErEEPROM read errorError occurred while reading parameter data from non-volatile storageHardware memory cell failure, internal control board failureCycle input power. Internal hardware fault — return unit for repair if persistent.
CE0Communication error / LECOM interruptionCommunication failure over LECOM interface or plug-in moduleCable fault, protocol timeout, disconnected communication interface moduleCheck communication cable, verify baud rate and address settings, check module connection
P13Transducer fault / Internal errorInternal current or voltage measurement sensor errorInternal measurement circuit fault, corrupted factory calibrationInternal hardware fault — return unit for repair.

Frequently Asked Questions

What engineering software is used to configure the Lenze 8102_E.4G.12 inverter?

The Lenze 8102_E.4G.12 is configured using Lenze Global Drive Control (GDC) PC software or locally via a plug-in keypad module.

How do I transfer parameters to a replacement Lenze 8102_E.4G.12 drive?

Parameter sets can be copied directly using a plug-in keypad module or uploaded and downloaded using Lenze Global Drive Control (GDC) software.

What does an OC5 fault code indicate on this inverter?

An OC5 fault code indicates an earth fault or phase-to-phase short circuit at the inverter output, which can be caused by motor cable failure, motor winding ground faults, or damaged internal output electronics.

What communication interfaces are supported by the Lenze 8102_E.4G.12?

The drive features a front module slot that accepts optional LECOM (RS-232/RS-485) communication modules or Lenze CAN system bus modules.

What modern drive options exist for upgrading from this legacy Lenze drive?

Lenze recommends upgrading to the 8400 or i500 inverter series when modernizing installations equipped with legacy 8100 series drives.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.