Lenze E82EV302_4B 8200 Vector 3.0 kW Frequency Inverter

New 
On request
Refurbished   
6 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 Vector | Series: 8200 Vector

The Lenze E82EV302_4B is a 3.0 kW frequency inverter from the 8200 Vector series, engineered to provide precise variable speed regulation and dynamic torque control for industrial three-phase asynchronous motors. Operating across a three-phase input voltage range of 320 V AC to 528 V AC at 400/480V, this compact IP20-rated inverter delivers a continuous output current of 7.3 A and supports output frequencies from 0 to 480 Hz with an 8 kHz switching frequency. Built with an integrated Class A / Category C2 radio interference filter (indicated by the _4B suffix), the unit suppresses electromagnetic interference directly within the power stage, saving enclosure space by eliminating the requirement for external RFI filter hardware. The inverter supports both sensorless vector control and programmable V/f characteristics, making it suitable for material handling systems, pump and fan control, and packaging machinery.

Featuring a modular system architecture, the E82EV302_4B separates its power section from functional interfaces, allowing customized integration through plug-in modules. Fieldbus and I/O expansion are handled via dedicated slots that accommodate standard I/O modules, CAN system bus, PROFIBUS-DP, INTERBUS, or LECOM serial modules. Commissioning a replacement unit requires restoring the process configuration, as the drive stores up to four independent, online-switchable parameter sets within internal EEPROM memory. Parameter configurations can be backed up and reloaded using the plug-in EMZ8201BB keypad module or via PC using Global Drive Control (GDC) software. When replacing a failed unit, technicians must swap the existing plug-in communication module to the spare unit and copy the parameter set to match the machine's operating parameters. ABC Industrial Parts can support maintenance teams with tested spare units and parameter extraction assistance to minimize production downtime.

Diagnostic feedback on the E82EV302_4B is provided through front-panel LEDs and digital fault reporting. A solid green indicator signals operational readiness, while a red LED illuminates continuously or flashes during active TRIP fault conditions. Detailed TRIP codes, such as OC1 (output short circuit), OU (DC bus overvoltage), OH (heatsink overtemperature), and CE0 (CAN communication error), can be read directly using the EMZ8201BB keypad or monitored live through Global Drive Control software. Internal non-volatile memory logs historical TRIP events for rapid root-cause analysis. Initial troubleshooting should include checking main supply fuses across input terminals L1, L2, and L3, inspecting motor cable insulation on U, V, and W terminals, and verifying that plug-in modules are firmly seated. Persistent power stage faults or EEPROM memory corruptions (code EER) indicate internal hardware damage that cannot be serviced in the field; in such cases, sourcing a refurbished replacement or arranging unit repair through ABC Industrial Parts provides a fast route back to full operation.

Technical Specifications

ManufacturerLenze
Part NumberE82EV302_4B
Model / Type8200 Vector E82EV302_4B
Product Family8200 Vector
Component TypeFrequency Inverter
Rated Power3.0 kW
Supply Voltage Range320 - 528 V AC
Rated Input Current7.3 A
Continuous Output Current7.3 A
Output Voltage400 V AC
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz
Control MethodSensorless Vector Control / V/f characteristic
EMC / RFI FilterIntegrated Class A / Category C2 Filter
Enclosure Protection RatingIP20

Programming and Configuration

The Lenze E82EV302_4B frequency inverter features internal non-volatile EEPROM memory for storing all operating parameters and drive settings. Up to four separate parameter sets can be saved internally and switched online during operation, allowing a single inverter to adapt to different motor profiles or process requirements without interrupting control execution.

Configuration and parameter setup are performed using either the plug-in EMZ8201BB keypad module or the Global Drive Control (GDC) PC tool. The keypad attaches directly to the front operating slot for local parameter adjustments, menu navigation, and parameter set cloning. Alternatively, GDC software connects via PC to provide complete parameter management, offline drive configuration, parameter set uploading/downloading, and real-time monitoring.

When installing a spare drive, parameter sets can be copied directly from the original unit using the keypad transfer function or loaded from a saved GDC project file on a PC. Restoring the exact motor parameters, ramp times, and fieldbus node configuration ensures that the replacement inverter matches the existing machine requirements.

Communication and System Integration

The modular architecture of the Lenze 8200 Vector series separates control and fieldbus communications from the main drive hardware. The E82EV302_4B features plug-in function slots that support various option modules, allowing the unit to adapt to multi-vendor automation architectures.

Available interface modules include the E82ZAFSC Standard I/O module for hardwired digital and analog control signals, the E82ZAFCC System Bus CAN module for integrated CANopen system networking, and the E82ZAFPC module for PROFIBUS-DP network connection. Serial communications are also supported via LECOM RS-232/485 interfaces or INTERBUS modules.

When swapping out a faulty drive, the plug-in function module can be unbolted and transferred directly to the replacement E82EV302_4B unit. Network parameters such as bus node addresses, DIP switch settings, and baud rates remain on the external module or must be verified in the parameter sets after mechanical installation.

Diagnostics and Status Indication

The front panel of the Lenze E82EV302_4B includes dual-color LED indicators for immediate visual diagnosis of operational states. A solid green LED confirms that the drive supply is normal and the inverter is ready for enable signals. A red LED illuminates solid or flashes when a TRIP fault condition occurs, signaling an active fault that disables drive output.

Detailed fault analysis is conducted via the optional EMZ8201BB keypad, which displays specific alphanumeric TRIP codes, or via Global Drive Control software connected to a PC. Historical fault logs stored in the inverter's internal EEPROM record past error codes, enabling maintenance technicians to trace intermittent trips and evaluate power supply stability, thermal loading, or motor output conditions.

Status LED Indicators

LEDColor/StatusMeaning
Ready/Operation IndicatorGreen - SolidOperational state active and ready for drive enable
Fault/TRIP IndicatorRed - Flashing or SolidActive fault or TRIP condition present

Replacement and Spare Part Considerations

When replacing an existing Lenze E82EV302_4B drive, ensure the part number matches precisely, specifically verifying the _4B suffix. This suffix confirms the presence of the integrated Class A / Category C2 RFI filter. Installing an unfiltered variant in a cabinet designed for integrated filtering may cause electromagnetic noise issues on adjacent control wiring.

A replacement unit cannot be operated directly out of the box without configuration. Maintenance personnel must transfer the existing plug-in option module (such as the E82ZAFSC Standard I/O or E82ZAFCC CAN module) to the new inverter base unit. Screws holding the module must be tightened securely to prevent function slot communication errors (code CE1).

Parameter restoration is required before powering up motor loads. Parameters can be copied using the EMZ8201BB keypad module or uploaded from a computer using Global Drive Control software. Ensure that parameters such as motor rated current (C0087), acceleration/deceleration ramps (C0012/C0013), and fieldbus configurations are fully transferred.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short CircuitShort circuit or ground fault detected on output motor terminals.Short circuit in motor cable or motor windings; earth fault; capacitive earth currents in long motor cables.Check motor and motor cables for insulation and short circuit; check output wiring. If fault persists with motor disconnected, internal power stage failure — contact service or replace unit.
OC2Overcurrent during AccelerationOutput current limit exceeded during acceleration phase.Acceleration time ramp set too short; motor undersized for load; excessive load torque.Increase acceleration time (C0012); check motor dimensioning and mechanical load.
OC3Overcurrent at Constant SpeedOutput current limit exceeded during constant speed operation.Sudden load impulse or jam; severe load fluctuation.Check mechanical application for blockage or dynamic load surges; verify motor parameters.
OC4Overcurrent during DecelerationOutput current limit exceeded during deceleration phase.Deceleration time set too short; high load inertia.Increase deceleration time ramp (C0013); fit dynamic braking resistor if required.
OC5I x t OverloadContinuous overload of inverter power stage (I x t thermal load dynamic calculated limit reached).Drive operated above rated continuous current for extended duration.Reduce motor load; verify drive current selection against process torque requirement.
OUOvervoltage DC BusDC bus voltage exceeded upper threshold limit.Regenerative energy from motor during deceleration; deceleration time too short; missing brake chopper/resistor; mains supply voltage too high.Extend deceleration time (C0013); install braking chopper and resistor; check mains supply voltage.
LUUndervoltage DC BusDC bus voltage fell below minimum allowable operating threshold.Mains supply failure; supply voltage too low; transient power drop.Check mains voltage input terminals; verify fuse and input supply continuity.
OHHeatsink OvertemperatureHeatsink temperature exceeded internal maximum threshold (> 90 °C).Insufficient cooling airflow; ambient temperature too high; cooling fan fault or clogged heatsink fins.Improve enclosure ventilation; clean heatsink cooling fins; verify cooling fan operation.
OH4Motor OvertemperatureMotor temperature switch / PTC thermistor sensor tripped on motor terminals T1, T2.Motor overheating; motor overloaded; thermal switch open; PTC thermistor tripped.Allow motor to cool down; check motor thermal loading; check motor sensor wiring.
OH7Motor Thermal Model (I x t) TRIPCalculated motor thermal overload limit reached via software motor protection model.Continuous low-speed operation under heavy load; incorrect motor rated current configured.Check parameter setting for motor rated current (C0087); check motor cooling capability at reduced speed.
CE0Communication Error - System Bus (CAN)Time-out or failure on CAN system bus interface.CAN network cable disconnected; bus termination missing; baud rate mismatch; CAN master stopped.Check CAN cabling and shielding; verify terminating resistors (120 Ohm); check master cyclic communications.
CE1Communication Error - Function Module SlotCommunication breakdown between inverter basic unit and plug-in function module.Function module loose or improperly seated; bad contact; defective module.Power down, reseat function module in slot, secure screws, re-apply power. If problem persists, hardware fault — replace function module or main unit.
EEREEPROM Memory ErrorChecksum or read/write failure in internal EEPROM parameter storage.Corrupted parameter memory; power interruption during parameter saving; hardware EEPROM fault.Reload factory default settings (C0002) and write parameters again. If EER error cannot be cleared, internal hardware failure — replace unit.
LP1Motor Phase FailureOutput motor phase loss detected.Loose connection on output U, V, W terminals; motor cable cut; high resistance contactor between inverter and motor.Check wiring between inverter output terminals U, V, W and motor terminals; check contactors and fuses.
P13Mains Phase FailurePhase missing or unsymmetrical AC supply voltage on input L1, L2, L3.Mains input fuse blown; loose supply phase wire; mains voltage supply imbalance.Check input line fuses and supply voltages across L1, L2, L3.
NMAXSpeed Limit ExceededActual motor speed exceeded maximum allowable limit.Field weakening range misconfigured; drive overspeed condition due to external driving load.Check speed limit parameters; verify load dynamics and field weakening parameters.

Frequently Asked Questions

What is the function of the _4B suffix in the part number E82EV302_4B?

The _4B suffix designates that the frequency inverter includes an integrated Class A / Category C2 radio interference filter, suppressing electromagnetic noise directly within the drive and avoiding the need for an external RFI filter.

Is the Lenze E82EV302_4B inverter a direct plug-and-play replacement?

No, a replacement unit requires parameter configuration and module transfer before operation. You must transfer the plug-in function module (such as I/O or CAN module) from the old unit and restore the parameter set using the EMZ8201BB keypad or Global Drive Control (GDC) software.

How are parameter sets transferred to a spare E82EV302_4B drive?

Parameters can be saved and copied using the plug-in EMZ8201BB keypad module or downloaded directly from a saved project file using Global Drive Control (GDC) PC software.

What does error code OC1 indicate on the Lenze E82EV302_4B?

Error code OC1 indicates a short circuit or earth fault on output terminals U, V, W. If the fault persists even with the motor disconnected, it points to an internal power stage failure requiring unit replacement or professional repair.

What do the green and red LEDs on the front panel signify?

A solid green LED indicates that the drive is powered and ready for operation. A solid or flashing red LED indicates an active TRIP fault condition that disables output power.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.