Lenze E82EV751_4B 8200 Vector Frequency Inverter 0.75 kW

New 
On request
Refurbished   
3 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 Vector | Series: 8200 Vector

The Lenze E82EV751_4B (model type E82EV751K4B) is a 0.75 kW frequency inverter belonging to the 8200 Vector drive series, engineered for precise variable speed control of standard asynchronous AC motors. Operating across a 3-phase mains supply voltage range of 320 V to 550 V AC, this compact IP20 panel-mountable drive delivers a continuous output current of 2.4 A with a peak overload capacity of 3.6 A (150%) for up to 60 seconds. Featuring an 8 kHz switching frequency and low internal thermal dissipation of 40 W, the unit supports V/f characteristic control, sensorless vector control, and open-loop torque control across an output frequency range of 0 to 480 Hz. Dedicated motor protection is integrated directly via thermal PTC thermistor connection terminals T1 and T2.

Integrating a replacement drive into an operational machine requires proper physical module alignment and parameter configuration. The modular architecture of the 8200 Vector series separates the main power section from control options, enabling direct installation of optional communication modules such as the CANopen module (E82ZAFCC) or PROFIBUS module (E82ZAFPC), alongside standard I/O function modules. Drive commissioning involves loading parameters across the unit's four internal parameter sets using either the pluggable Keypad XT (E82ZBC) interface or Lenze Global Drive Control (GDC) PC software. When restoring machine operation from a failed drive, ABC Industrial Parts provides assistance with replacement unit preparation and parameter extraction from donor or failing hardware.

Real-time monitoring and field troubleshooting rely on three front-panel status LEDs and structured diagnostic parameter menus. System operational state is signaled via the green LED for normal operation or impulse inhibit, the yellow LED for warning thresholds, and the red TRIP LED for fault conditions requiring a reset. Active fault codes are stored in parameter C0183, while parameter C0168 maintains a timestamped history log of the four most recent error events. Common field trips such as OC1 overcurrent, OU DC-bus overvoltage, or LU undervoltage can usually be addressed by inspecting motor wiring, supply fuses, and deceleration ramp timing. Internal electronics or memory failures such as EE08 or H05 indicate non-serviceable internal board issues, where securing a tested replacement unit or utilizing repair services from ABC Industrial Parts offers the most direct path to minimize line downtime.

Technical Specifications

ManufacturerLenze
Part NumberE82EV751_4B
Model / TypeE82EV751K4B
Product Family8200 Vector
Component TypeFrequency Inverter
Rated Power0.75 kW
Supply Voltage Range320 V - 550 V AC (3-Phase)
Continuous Output Current2.4 A
Maximum Output Current (60s)3.6 A
Mains Input Current (Without Choke)3.3 A
Mains Input Current (With Choke)2.2 A
Output Frequency Range0 Hz - 480 Hz
Switching Frequency8 kHz
Power Dissipation40 W
Control MethodV/f characteristic control, sensorless vector control, torque control
IP RatingIP20
Mounting TypePanel mounting / cabinet installation

Programming and Configuration

Parameter management on the Lenze E82EV751_4B inverter is conducted using either the pluggable Keypad XT (E82ZBC) or Lenze Global Drive Control (GDC) engineering software via a connected PC interface. The inverter contains four internal parameter sets, allowing engineers to store alternate machine configurations or process profiles directly within the drive hardware. Key setup parameters govern crucial motor dynamics, including acceleration ramp time (parameter C0012), deceleration ramp time (parameter C0013), and thermal motor monitoring thresholds (parameters C0075 and C0076).

When swapping out an old or damaged unit, parameter backup files can be downloaded from GDC software or saved directly onto the Keypad XT memory module. Re-commissioning a new spare involves snapping the pre-programmed Keypad XT onto the fresh power unit or performing a direct parameter download via GDC. If corruption occurs during initialization, memory parameters can be reset to factory default values before re-uploading the operational parameter profile.

Communication and System Integration

The 8200 Vector series features a modular physical interface architecture that decouples the primary power section from fieldbus networking interfaces. Communication options attach directly to the front slot of the base unit, enabling seamless system integration into existing fieldbus architectures without requiring changes to the main drive wiring.

Supported fieldbus modules include the CANopen Function Module (E82ZAFCC) and the PROFIBUS Module (E82ZAFPC), alongside options for INTERBUS and DeviceNet protocols. The drive also supports internal CAN system bus networking for high-speed cross-communication between multiple Lenze drives. When replacing an inverter, the existing communication module can be unclipped from the donor drive and installed directly onto the replacement unit.

Diagnostics and Status Indication

The E82EV751_4B inverter features three LED status indicators located on the front panel to provide immediate operational feedback to maintenance personnel. Supplementary digital diagnostics are accessible through the Keypad XT display interface or via parameter monitoring in Global Drive Control (GDC) software.

Parameter C0183 provides real-time active fault code readouts, while parameter C0168 logs the four most recent fault events complete with operating time stamps for root-cause analysis. Diagnostic traces can also be captured in real time through GDC software to evaluate dynamic load conditions, voltage drops, or current spikes.

Status LED Indicators

LEDColor/StatusMeaning
Red LED (TRIP / Fault indicator)Red - Solid or FlashingFlashes or lights solid when a fault condition occurs. Solid light indicates an active fault/trip requiring a reset.
Green LED (Operation / Ready indicator)Green - Solid or FlashingLights solid during normal operation; flashes when impulse inhibit is active or drive is preparing for operation.
Yellow LED (Warning / Impulse inhibit)Yellow - Solid or FlashingLights or flashes when warning limit is reached or impulse inhibit is active.

Replacement and Spare Part Considerations

When replacing an E82EV751_4B inverter, ensure that both the main power unit part number and installed option modules match the original installation. Communication cards such as the CANopen (E82ZAFCC) or PROFIBUS (E82ZAFPC) modules, along with keypad interfaces like the Keypad XT (E82ZBC), are transferable to the replacement base unit.

The spare unit will not operate correctly until the original parameter backup is loaded onto its memory. Transfer parameters using the Keypad XT module or upload the configuration file via Global Drive Control (GDC) software. For modernizing equipment or complete machine overhauls, Lenze i510 and i550 series cabinet frequency inverters serve as recommended replacement series.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuit / Earth faultInstantaneous overcurrent caused by short circuit at output or earth fault in motor/cableShort circuit between motor phases; ground fault in motor or wiring; motor cable too long; acceleration time too shortCheck motor and wiring for short circuit and insulation integrity; check cable length and shielding; increase acceleration time
OC2Overcurrent during accelerationDrive current limit exceeded during acceleration phaseAcceleration time set too short; motor mechanically jammed or load inertia too high; incorrect motor data enteredIncrease acceleration time (C0012); check mechanical drive train for stiffness; verify motor parameters
OC3Overcurrent during decelerationDrive current limit exceeded during deceleration phaseDeceleration time set too short; braking energy too highIncrease deceleration time (C0013); fit optional brake chopper / brake resistor
OC5I x t overload (Inverter)Thermal overload of frequency inverter power section due to continuous high currentContinuous operation above rated continuous output current; duty cycle too severeReduce drive load; check switching frequency setting; select larger inverter rating
OC6I²t overload (Motor)Thermal overload calculation for motor exceeded allowed limitMotor operated at low speed under high load for extended duration without external coolingCheck motor loading; verify I²t settings (C0075/C0076); use forced cooling motor fan
OUOvervoltage in DC busDC bus voltage exceeds maximum allowed voltage limitExcessive regenerative energy during deceleration; mains supply voltage too highIncrease deceleration time; install braking module/resistor; check mains voltage
LUUndervoltage in DC busDC bus voltage dropped below minimum threshold limitMains supply failure; phase loss; input supply voltage too low; transient power dropCheck mains voltage; check supply wiring and fuses; verify line choke
OHHeatsink overtemperatureHeatsink temperature exceeds maximum permitted limitInsufficient cooling airflow; ambient temperature too high; fan defect or clogged cooling finsClean heatsink cooling fins; check control cabinet ventilation; reduce ambient temperature
OH3Motor thermal overload (PTC)Motor temperature sensor connected to T1/T2 terminals triggered tripMotor overheating due to overload or blocked cooling air flowAllow motor to cool down; eliminate motor overload; check motor ventilation
OH4Inverter inside overtemperatureInternal air temperature inside inverter control board exceeds limitExcessive cabinet temperature; fan failureImprove cabinet cooling and airflow
EE08EEPROM memory faultInternal EEPROM data corruption or reading error during startupInternal memory corruption; hardware fault on control boardRe-initialize parameters to factory defaults; if error persists, internal hardware fault — return unit for repair
CE0Communication fault (Function module)Communication failure between basic inverter unit and installed function moduleFunction module improperly seated or defective; loose connectionCheck seating of option module; replace option module; replace main unit if persistent
CE1System bus (CAN) communication faultCommunication interruption or error on CAN system bus interfaceBus cable disconnected; incorrect bus termination; baud rate mismatchCheck CAN wiring, termination resistors, and node configuration settings
LP1Motor phase failureLoss of single motor phase detected at output terminalsMotor cable disconnected or broken phase line; motor winding openCheck motor cables and connection terminal block; test motor resistance
P12Mains phase failureLoss of input phase detected on 3-phase AC input supplyBlown supply fuse; phase loss in mains distributionCheck input fuses and mains voltage stability across all 3 phases
H05Internal hardware faultInternal microprocessor or hardware defect detected during self-testInternal board component breakdownInternal hardware failure — replace unit or return to manufacturer service

Frequently Asked Questions

What software is used to program the Lenze E82EV751_4B drive?

The drive is configured using Lenze Global Drive Control (GDC) PC software or configured directly using the pluggable Keypad XT (E82ZBC) module.

Can I transfer parameters to a replacement drive without a PC connection?

Yes, parameters saved onto a Keypad XT (E82ZBC) digital display module can be plugged into a replacement drive to transfer configuration profiles across all four parameter sets.

How do I clear an EE08 memory fault on startup?

An EE08 fault indicates EEPROM corruption. Re-initialize parameters back to factory defaults. If the fault persists after re-initialization, the drive has suffered an internal hardware fault and requires repair or replacement.

Which fieldbus modules can be used with the E82EV751_4B inverter?

The modular drive architecture supports CANopen (E82ZAFCC) and PROFIBUS (E82ZAFPC) modules, as well as INTERBUS and DeviceNet option modules.

What modern Lenze drive series is recommended to replace legacy 8200 Vector inverters?

Lenze i510 and i550 cabinet frequency inverters are recommended as replacement series for legacy 8200 Vector drives.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.