The Lenze E84AVSCE1522SX0 is a panel-mounted 1.5 kW frequency inverter belonging to the 8400 StateLine C series within the Lenze Inverter Drives 8400 family. Operating across a line input voltage range of 180 V to 264 V AC on single-phase or three-phase 230 V networks, this compact drive provides dynamic speed and torque regulation for three-phase AC asynchronous motors. Supporting standard V/f characteristic control and Sensorless Vector Control (SLVC), the unit delivers controlled motion up to an output frequency of 599 Hz with a continuous output current rating of 7 A at an 8 kHz switching frequency. Functional safety is directly integrated into the unit through Safe Torque Off (STO), certified to EN ISO 13849-1 (PL e) and EN 62061 / IEC 61508 (SIL 3) standards to minimize external electromechanical safety hardware.
For physical control and signal interface, the drive features five 24 V DC digital logic inputs, one digital output, a 12-bit configurable analog input (supporting 0–10 V, ±10 V, or 0/4–20 mA), and a 0–10 V analog output. Network connectivity is established natively through an onboard CANopen system interface operating at baud rates up to 1000 kbit/s, along with an MCI extension slot that accommodates optional communication cards such as PROFIBUS (E84AYCPM), PROFINET (E84AYCER), or EtherCAT (E84AYCET). Commissioning or replacing an active unit is simplified by a pluggable EEPROM memory chip containing the complete drive parameter set, allowing rapid hardware swaps without software tools. ABC Industrial Parts can support maintenance teams with tested replacement hardware and compatible system components to keep production equipment running.
Diagnostic monitoring is facilitated by front-mounted status LEDs including DRIVE RDY, DRIVE ERROR, CAN RUN, and CAN ERR, which provide instantaneous status checks for inverter operation and fieldbus activity. Detailed parameter extraction, runtime values, and error memory buffers are accessible via parameters C00150, C00009, and C00160 using the Keypad X400 (E84DDFXP000) or Lenze L-force Engineer software version 2.6 or higher. Common operational trips like DC bus overvoltage (code 0x00230001), motor phase failure (code 0x00240001), or memory module issues (code 0x00510001) can often be addressed through wiring checks, ramp time adjustments, or memory module re-seating. Persistent hardware faults such as power section failures (code 0x00250001) indicate board-level damage where a full unit replacement or repair service through ABC Industrial Parts provides the quickest path to restoring machine operations.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | E84AVSCE1522SX0 |
| Model / Type | 8400 StateLine C |
| Product Family | Inverter Drives 8400 |
| Component Type | Frequency Inverter |
| Rated Power | 1.5 kW |
| Supply Voltage | 1/N/PE AC 230 / 3/PE AC 230 |
| Supply Voltage Range | 180 - 264 V AC |
| Continuous Output Current | 7 A |
| Maximum Output Frequency | 599 Hz |
| Switching Frequency | 8 kHz |
| Control Method | V/f control, Sensorless Vector Control (SLVC) |
| Digital Inputs | 5 |
| Digital Outputs | 1 |
| Analog Inputs | 1 (12-bit, selectable 0-10V, ±10V, 0/4-20mA) |
| Analog Outputs | 1 (0-10 V) |
| Mounting Type | Panel Mount |
| Integrated Safety Function | Safe Torque Off (STO), PL e / SIL 3 |
Programming and Configuration
Drive setup and parameterization for the Lenze E84AVSCE1522SX0 frequency inverter are performed using Lenze L-force Engineer engineering software (version 2.6 or higher). Engineering connections can be established using the USB Diagnostic Adapter (E84EZCEUSB) attached to the front diagnostic port, or parameters can be edited directly on the machine panel using the optional plug-in Keypad X400 (E84DDFXP000). The software interface supports real-time parameter configuration, speed profile tuning, and oscilloscope function trace monitoring.
Complete parameter storage is handled via a front-accessible, pluggable EEPROM memory module chip. The memory chip stores all motor parameters, V/f and vector control profiles, safe torque off configurations, fieldbus addresses, and custom I/O mappings. Because all configuration settings reside on this physical chip, parameter sets can be duplicated or transferred without maintaining active software licenses on local field service computers.
When commissioning a spare inverter unit, parameters stored on the memory module can be loaded into the drive control unit upon power-up. Technicians can also extract or back up dataset structures via L-force Engineer to maintain master archives for facility equipment management.
Communication and System Integration
The 8400 StateLine C drive provides standard system integration capabilities through a built-in CANopen interface capable of bus communication speeds up to 1000 kbit/s. Dedicated front panel LEDs (CAN RUN and CAN ERR) report network operational states, pre-operational modes, and communication bus errors in real time.
For integration into broader higher-level industrial networks, the inverter incorporates an MCI extension slot designed for optional plug-in fieldbus modules. Supported modules include the E84AYCPM PROFIBUS-DP card, E84AYCER PROFINET card, and E84AYCET EtherCAT card, allowing flexible network alignment without altering core drive wiring.
Control terminal connections include five 24 V DC digital logic inputs and one digital logic output for hardware interlocks and control commands. Analog control features one 12-bit multi-range input accepting 0–10 V, ±10 V, or 0/4–20 mA signals, alongside one 0–10 V analog output for actual value feedback.
Diagnostics and Status Indication
Visual status diagnostics are displayed directly on the unit via four dedicated LED indicators covering general drive operation and CANopen fieldbus state. Additional diagnostic tools include the interactive menu system on the optional Keypad X400 and the diagnostic monitor inside L-force Engineer.
System state monitoring and fault tracking utilize specific internal parameters. Parameter C00150 and C00009 provide live status and operating readouts, while parameter C00160 grants direct access to the active fault memory buffer for troubleshooting trip histories.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| DRIVE RDY | Green - Solid / Blinking | Green solid: Drive ready for operation / enabled; Blinking green: Drive initialized / inhibited. |
| DRIVE ERROR | Red - Solid / Flashing | Red solid: Active fault condition / trip error; Flashing red: Warning level active. |
| CAN RUN | Green - Solid / Blinking | Green solid: CANopen bus state Operational; Blinking green: Pre-Operational / Stopped. |
| CAN ERR | Red - Solid | Red solid: CANopen communication error or bus off condition. |
Replacement and Spare Part Considerations
Replacing a damaged Lenze E84AVSCE1522SX0 drive is designed to minimize downtime through the use of the removable EEPROM memory chip. By physically transferring the memory module from the original drive to the replacement unit, all motor, safety, and network parameters are retained without needing to re-commission the drive via software.
Before restoring power to a replacement unit, verify that line power input matches the required 180–264 V AC specification and that motor cable connections (U, V, W) and STO safety circuit input terminals are secured. Any installed MCI fieldbus module, such as a PROFIBUS (E84AYCPM) or PROFINET (E84AYCER) card, must be moved to the replacement drive's MCI slot.
For long-term machinery lifecycle planning, Lenze offers the i550 cabinet series as a recommended successor series. However, maintaining exact Lenze E84AVSCE1522SX0 8400 StateLine C replacement units allows direct form-fit-function replacement without control cabinet modification or PLC project redesign.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| 0x00110011 | OC1 Short Circuit / Earth Fault | Short circuit or earth fault on output phases U, V, W. | Motor cable short circuit, motor winding fault, earth fault on motor leads, excessively long cable without motor filter. | Check motor wiring and isolation resistance; inspect motor windings; test power output stage. If wiring is fine and fault persists on power-up without motor connected, output power module is damaged — internal board-level failure requiring repair or replacement. |
| 0x00210001 | I2t Motor Overload | Calculated motor thermal load exceeded maximum value. | Continuous mechanical overload, motor dimensioned too small, incorrect motor thermal parameters in drive configuration. | Check mechanical load and drive duty cycle; verify motor nameplate data in parameter settings. |
| 0x00220001 | OH Heatsink Overtemperature | Heatsink temperature exceeded allowable threshold limit. | Inadequate control cabinet cooling, fan obstructed or failed, ambient temperature too high, switching frequency set too high for load. | Clean heatsink cooling fins, check cabinet ventilation, verify fan operation, lower switching frequency. |
| 0x00220002 | OH4 Inside Temperature Exceeded | Internal air temperature inside inverter housing exceeds thermal limit. | Ambient temperature too high, internal fan failure. | Check ambient temperature and enclosure ventilation. Replace unit if internal fan/sensor has failed. |
| 0x00230001 | OU DC Bus Overvoltage | Voltage level in DC bus circuit exceeds overvoltage shutdown threshold. | Deceleration ramp time set too short during high load inertia, regenerative energy feedback, missing or defective brake resistor. | Extend deceleration time ramp; install or inspect external brake resistor / brake chopper circuit. |
| 0x00230002 | LU DC Bus Undervoltage | Voltage in DC bus dropped below minimum threshold limit. | Mains voltage supply drop, phase loss, power supply interruption. | Check supply mains line voltage, fused connections, and input wiring. |
| 0x00240001 | Motor Phase Failure | Loss of connection on one or more output motor phases (U, V, W). | Loose cable connection at terminal strip, motor contactor open, broken motor wire. | Inspect motor cabling and terminal connections on inverter output stage. |
| 0x00250001 | Power Section Hardware Fault | Internal hardware failure detected in power section circuit. | Gate driver circuit error, internal power module fault, overcurrent hardware detection logic tripped. | Internal board-level hardware fault — not field serviceable. Replace the inverter unit. |
| 0x00310001 | Safe Torque Off (STO) Active | Integrated safety function Safe Torque Off activated. | Safety circuit open, safety relay or e-stop button tripped. | Check external safety circuit logic and safety input terminals on drive. |
| 0x00510001 | Memory Module Error | Memory chip missing, unreadable, or invalid dataset detected upon startup. | Memory module improperly seated, corrupted parameter dataset, hardware defect on memory chip. | Re-insert memory module securely; re-write parameter file using L-force Engineer. Replace memory chip if corrupted. |
| 0x00610001 | Internal System Fault | Internal microprocessor system failure or microcontroller watch-dog trip. | Firmware corruption, electronic component breakdown. | Cycle power to drive. If error persists, internal hardware fault exists — replace unit. |
Frequently Asked Questions
How do I transfer drive settings to a replacement Lenze E84AVSCE1522SX0 unit?
You can transfer all configuration data by removing the EEPROM memory chip from the old drive and inserting it into the replacement unit. This transfers all parameters without requiring a PC or software tools.
What software and accessories are used to program the drive?
The inverter is configured using Lenze L-force Engineer software version 2.6 or higher. Local connections can be made using the USB Diagnostic Adapter (E84EZCEUSB) or the Keypad X400 (E84DDFXP000).
Does the E84AVSCE1522SX0 include built-in safety functions?
Yes, the drive includes integrated Safe Torque Off (STO) functional safety certified to EN ISO 13849-1 (PL e) and EN 62061 / IEC 61508 (SIL 3).
Can this drive be connected to PROFIBUS or PROFINET networks?
Yes. While CANopen is integrated onboard, optional MCI expansion modules can be plugged into the drive slot to support PROFIBUS (E84AYCPM), PROFINET (E84AYCER), or EtherCAT (E84AYCET).
What action should be taken if error code 0x00250001 occurs?
Error code 0x00250001 indicates an internal power section hardware fault within the power module or gate driver circuit. This condition is not field-serviceable and requires replacing the inverter unit.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.