Lenze E84AVSCE5512SB0 8400 StateLine C Frequency Inverter 0.55kW

New 
1 available within 2 - 3 business days
Refurbished   
On request
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8400 Series | Series: StateLine C

The Lenze E84AVSCE5512SB0 is an industrial frequency inverter from the 8400 StateLine C product line within the Lenze 8400 Series. Designed for speed-controlled three-phase AC motor drive applications in conveyor systems, pumps, fans, and packaging machinery, this compact panel-mount unit operates on a 230 V AC supply voltage with an operating range of 180 V to 264 V AC. It delivers a rated output power of 0.55 kW with a 3 A continuous output current and a 6 A mains input current. Motor control is driven through linear or quadratic V/f characteristic control or Sensorless Vector Control (SLVC), supporting an output frequency range from 0 to 599 Hz with switching frequencies up to 16 kHz for quiet motor operation. Functional safety is integrated directly into the hardware through Safe Torque Off (STO), certified to SIL 3 per EN 62061 and PL e per EN ISO 13849-1, eliminating the requirement for external safety contactors in emergency stop loops.

For network and field control, the E84AVSCE5512SB0 incorporates an onboard CANopen system bus capable of communication rates up to 500 kbit/s, along with hardwired terminals providing 5 digital inputs, 1 digital output, 1 relay output, 1 analog input, and 1 analog output. Industrial communication capabilities can be expanded using optional plug-in modules, such as the E84AYCPM PROFIBUS module, E84AYCER PROFINET module, or E84AYCET EtherCAT module, as well as EtherNet/IP and Modbus TCP units. Engineering setup is supported via Lenze EASY Starter or L-force Engineer software, or directly at the drive using the pluggable L-force Diagnostics Keypad X100 (EZAEBK1001). Commissioning a replacement unit is straightforward thanks to the removable Lenze E84AYM200 EEPROM memory module. Transferring the original memory card into a replacement drive copies the complete parameter set instantly without software tools or PC connectivity. When configuring or recovering parameter files, ABC Industrial Parts provides technical support and tested replacement hardware to get machines back into operation.

Drive diagnostic states are shown on the front panel via status LEDs, including DRV-READY for operational status, DRV-ERR for active trip faults and warnings, CAN-RUN for CANbus network status, and CAN-ERR for bus communication errors. Active status registers and the fault buffer can also be interrogated over fieldbus connections or read out using EASY Starter software or the X100 keypad. When a fault occurs—such as short circuit/overcurrent (OC1), DC bus overvoltage (OU), or heatsink overtemperature (OH)—initial checks should focus on motor winding insulation, mains input voltage, and cabinet ventilation. For non-recoverable internal micro-controller or hardware supervisory failures represented by code 0x00110001, internal components cannot be serviced in the field. In situations where internal board faults persist after power cycling, obtaining a fully tested replacement drive or utilizing exchange units through ABC Industrial Parts ensures rapid recovery of machine operations.

Technical Specifications

ManufacturerLenze
Part NumberE84AVSCE5512SB0
Model / Type8400 StateLine C
Product Family8400 Series
Component TypeFrequency Inverter
Rated Power0.55 kW
Supply Voltage230 V AC
Supply Voltage Range180 - 264 V AC
Rated Output Current3 A
Mains Input Current6 A
Output Frequency Range0 - 599 Hz
Switching Frequency8 kHz
Control ModeV/f Characteristic Control / Sensorless Vector Control (SLVC)
Integrated SafetySafe Torque Off (STO) PL e / SIL 3
Integrated FieldbusCANopen / CAN System Bus
Protection RatingIP20
Mounting TypePanel Mount
Digital Inputs5
Digital Outputs1
Relay Outputs1
Analog Inputs1
Analog Outputs1

Programming and Configuration

Drive setup and parameter adjustments for the Lenze E84AVSCE5512SB0 are managed using Lenze EASY Starter or L-force Engineer commissioning tools. These software packages allow technicians to configure motor parameter sets, adjust acceleration and deceleration ramp times, define V/f or Sensorless Vector Control (SLVC) curves, and assign function logic to the onboard digital and analog terminals.

Parameter management and offline backups rely on the pluggable Lenze E84AYM200 EEPROM memory module. All operational parameters are stored directly on this module, allowing full device parameters to be preserved independently of the main controller hardware. Local parameter monitoring and parameter adjustments can also be executed at the machine enclosure using the optional Lenze L-force Diagnostics Keypad X100 (EZAEBK1001), which mounts onto the drive front interface.

Communication and System Integration

The E84AVSCE5512SB0 includes an integrated CANopen system bus interface operating up to 500 kbit/s. This built-in protocol provides direct real-time communication, operational command transfer, and parameter exchange across CANbus automation networks without requiring optional network cards.

To integrate into higher-level industrial network structures, the 8400 StateLine C inverter accepts plug-in fieldbus extension modules. Supported options include the E84AYCPM PROFIBUS DP module, E84AYCER PROFINET module, and E84AYCET EtherCAT module, as well as modules for EtherNet/IP and Modbus TCP. Hardwired control signals interface via 5 digital inputs, 1 digital output, 1 relay output, 1 analog input, and 1 analog output.

Diagnostics and Status Indication

Operational status and network conditions are monitored through four status LEDs located on the inverter front panel. These LEDs provide real-time status reporting for the drive power stage, general fault conditions, and active CANopen bus communication.

Comprehensive diagnostic routines can be performed by interrogating the drive error buffer using EASY Starter software or the L-force Diagnostics Keypad X100 (EZAEBK1001). Status words and fault memory logs are also continuously accessible via the CANopen system bus or installed fieldbus extension modules.

Status LED Indicators

LEDColor/StatusMeaning
DRV-READYGreen - Solid / FlashingSolid Green = Ready / Running; Flashing Green = Drive enabled / operation active
DRV-ERRRed - Solid / FlashingSolid Red = Active trip fault / lockout; Flashing Red = Warning or minor fault
CAN-RUNGreen - OperationalIndicates CANbus network operational state
CAN-ERRRed - ErrorIndicates CANbus network communication error

Replacement and Spare Part Considerations

When selecting a spare drive for the E84AVSCE5512SB0, verify that the replacement matches the specific part number and power rating of 0.55 kW with a 230 V AC supply. Because full device configurations are stored on the pluggable E84AYM200 memory card, physical unit replacements can be completed by moving the memory module from the original drive to the spare unit, restoring operational parameters without requiring engineering software.

If the unit uses optional fieldbus modules—such as PROFIBUS (E84AYCPM), PROFINET (E84AYCER), or EtherCAT (E84AYCET)—unclip these cards from the existing drive and transfer them to the replacement unit, ensuring any DIP address switches or rotary selectors are aligned with original network settings. For long-term equipment lifecycle planning, the Lenze i550 cabinet inverter series (part number i55AE155B00000000S) serves as the functional successor to this series.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
0x00210001OC1 (Short circuit / Overcurrent)Short circuit or severe overcurrent condition on inverter output motor terminals.Short circuit in motor winding or cable; earth fault; acceleration time too short; motor undersized.Check motor cable and winding insulation; increase acceleration time; check drive sizing.
0x00210002OC2 (Acceleration Overcurrent)Overcurrent detected during motor acceleration phase.Ramp time too short; heavy mechanical load / block; incorrect V/f characteristic setting.Increase acceleration time (Ti); check motor load and mechanical binding; check motor data parameters.
0x00210005OC5 (I2t Motor Overload)Motor overload calculation (I2t) exceeded permitted threshold.Continuous motor operation at high current / low speed without force cooling; mechanical overload.Reduce motor mechanical load; check motor current rating; allow motor to cool.
0x00220001OU (DC Bus Overvoltage)DC bus voltage exceeded upper safety shutdown limit.Braking energy feedback from motor during deceleration; deceleration time too short; mains supply voltage too high.Increase deceleration ramp time; install brake chopper / brake resistor; check mains supply voltage.
0x00230001LU (DC Bus Undervoltage)DC bus voltage fell below lower operational threshold.Mains power supply interruption; supply phase failure; input supply voltage too low.Check mains input voltage and power lines; verify fuses and main contractor connection.
0x00240001OH (Heatsink Overtemperature)Inverter heatsink temperature exceeded maximum allowed limit.Insufficient cooling airflow; ambient temperature too high; cooling fan failure / clogged heat sink fins.Clean heatsink cooling fins; verify control cabinet ventilation; reduce ambient temperature or switching frequency.
0x00240004OH4 (Motor Overtemperature)Motor temperature switch or PTC sensor triggered overtemperature alarm.Motor thermal overload; defective motor cooling fan; incorrect motor thermal switch connection.Allow motor to cool down; check motor ventilation; verify PTC / TKO terminal connection.
0x00210006EF (Earth Fault)Earth fault / ground current detected on motor phases.Motor phase insulation breakdown to ground; ground leak in motor wiring.Test motor phase-to-ground insulation with insulation tester; inspect motor cable for damage.
0x00310001PI (Parameter Fault / Memory Module Error)Parameter data in Memory Module corrupted or incompatible.Memory module removed during write operation; corrupt parameter dataset; incompatible firmware build.Re-download parameter set using EASY Starter; replace memory module; perform factory reset.
0x00110001System Fault / Hardware FailureInternal hardware or micro-controller supervisory fault.Internal power supply or processor failure; internal board component failure.Internal hardware fault — power cycle unit. If fault persists, return unit for service or replace inverter.

Frequently Asked Questions

How are parameter settings transferred to a replacement E84AVSCE5512SB0 drive?

Parameter settings can be transferred directly without software tools by swapping the removable Lenze E84AYM200 EEPROM memory module from the original drive into the replacement unit. Parameter sets can also be uploaded and downloaded using Lenze EASY Starter software or the L-force Diagnostics Keypad X100.

What functional safety capability is built into the E84AVSCE5512SB0?

The frequency inverter features integrated Safe Torque Off (STO) functional safety certified to SIL 3 according to EN 62061 and Performance Level e (PL e) according to EN ISO 13849-1. This feature safely disables motor torque without requiring external safety contactors.

Which fieldbus options can be used with the Lenze 8400 StateLine C inverter?

The inverter includes a built-in CANopen system bus operating up to 500 kbit/s. Optional plug-in communication modules add support for PROFINET (E84AYCER), PROFIBUS DP (E84AYCPM), EtherCAT (E84AYCET), EtherNet/IP, and Modbus TCP.

What engineering software is compatible with this drive for setup and diagnostics?

Drive configuration, parameterization, and error memory extraction can be performed using Lenze EASY Starter or L-force Engineer software. Offline handheld adjustments can also be executed using the L-force Diagnostics Keypad X100.

What is the official successor model for the E84AVSCE5512SB0 frequency inverter?

The official successor model for this 0.55 kW 230 V AC unit is the Lenze i550 cabinet inverter series, specifically part number i55AE155B00000000S.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.