Lenze E84AVTCE1524SX0 8400 TopLine C Frequency Inverter 1.5kW

New 
1 available within 2 - 3 business days
Refurbished   
On request
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: Inverter Drives 8400

The Lenze E84AVTCE1524SX0 is a 1.5 kW frequency inverter belonging to the 8400 TopLine C model line within the Inverter Drives 8400 family. Designed for cabinet mounting with an IP20 protection rating, this drive operates on a 3-phase input voltage range from 320 V to 528 V AC. It provides a rated continuous output current of 3.9 A with dynamic overload capacity reaching up to 5.85 A for 60 seconds. Capable of generating output frequencies from 0 to 599 Hz across an output voltage range of 0 to 400 V AC at an 8 kHz switching frequency, it supports dynamic positioning, trajectory generation, and synchronized motion control. The device features integrated Safe Torque Off (STO) functional safety circuitry, eliminating the need for separate external safety relays in compliant machine installations.

For network control and sensor integration, the E84AVTCE1524SX0 comes equipped with an onboard CANopen system bus interface and a 15-pin Sub-D connector that supports universal encoder feedback, including Resolvers, HTL, TTL, SinCos, and SSI absolute encoders. Modular networking is expanded through an integrated MCI extension slot, accommodating option modules such as PROFINET (E84AYCER), PROFIBUS (E84AYCPM), and EtherCAT (E84AYCET). Commissioning a replacement unit is streamlined via the pluggable EAM918 EEPROM memory module, which holds the device parameter set, CAN network IDs, and custom logic. This memory chip can be removed directly from a faulty unit and inserted into a replacement drive for tool-free parameter transfer without requiring software tools. Online parameter backup, commissioning, and drive configuration can also be executed using Lenze EASY Starter or L-force Engineer software. ABC Industrial Parts can support maintenance teams with replacement units and matching hardware accessories to keep production systems operating.

Diagnostic indication is provided on the front panel by dedicated status LEDs covering drive ready, drive busy, and CANopen communication states. Detailed diagnostic messaging and error codes can be reviewed using an optional EZAEBK100 Keypad XT diagnostic tool or through EASY Starter software. When persistent error conditions occur—such as output short circuits (OC1), DC-bus overvoltage (OU), undervoltage (LU), or parameter set corruption (PI)—first-line checks on power wiring, fieldbus cables, and external braking resistors can isolate external faults. Hardware self-test failures, such as internal error H01, point to internal electronic component damage that cannot be serviced on site; in these situations, securing a tested exchange unit or utilizing professional repair services from ABC Industrial Parts provides a direct solution to restore full drive functionality.

Technical Specifications

ManufacturerLenze
Part NumberE84AVTCE1524SX0
Model / Type8400 TopLine C
Product FamilyInverter Drives 8400
Component TypeFrequency Inverter
Rated Power1.5 kW
Supply Voltage Range320 - 528 V AC
Rated Continuous Current3.9 A
Peak Output Current5.85 A
Output Voltage Range0 - 400 V AC
Output Frequency0 - 599 Hz
Switching Frequency8 kHz
Digital Inputs8
Digital Outputs4
Analog Inputs2
Analog Outputs2
Integrated System BusCANopen
IP RatingIP20

Programming and Configuration

Drive setup and parameterization for the Lenze E84AVTCE1524SX0 are performed using Lenze EASY Starter or L-force Engineer software packages. These engineering tools give technicians access to motor parameter settings, trajectory generation, positioning profiles, and internal I/O mapping across the drive's 8 digital inputs, 4 digital outputs, 2 analog inputs, and 2 analog outputs. Integrated Safe Torque Off (STO) functional safety parameters are also managed within the system logic to ensure safe shutdown performance without external safety relays.

Parameter management is supported locally through the pluggable Lenze EAM918 EEPROM memory module. Complete device configurations—including control parameters, CAN IDs, and customer-specific motion profiles—are written directly to this module during operation. When substituting a unit during maintenance, transferring the existing EAM918 module into the replacement inverter duplicates the full parameter set without connecting a PC or reloading software project files.

Communication and System Integration

The Lenze 8400 TopLine C inverter features an onboard CANopen system bus interface for system-level networking and axis synchronization. In addition to standard CANopen capabilities, the hardware includes a modular MCI extension slot designed to accept fieldbus communication cards. Supported MCI modules include PROFINET (E84AYCER), PROFIBUS (E84AYCPM), and EtherCAT (E84AYCET), allowing the drive to integrate directly into higher-level PLC architectures such as EtherNet/IP or POWERLINK environments.

Feedback integration is handled via a dedicated 15-pin Sub-D multi-encoder interface connector. This universal feedback interface supports a wide variety of motor feedback devices, including Resolvers, HTL, TTL, SinCos, and SSI absolute encoders. This flexibility enables high-accuracy positioning, dynamic trajectory execution, and multi-axis speed synchronization across diverse packaging, logistics, and material handling machinery.

Diagnostics and Status Indication

The front panel of the E84AVTCE1524SX0 drive includes diagnostic status LEDs that provide visual information regarding operational states and fieldbus activity. Drive status is tracked through the DRV-READY and DRV-BUSY indicators, while fieldbus communications on the CANopen network are reported by the CAN-RUN and CAN-ERR LEDs. System status, active parameters, and error history can also be read directly via the optional EZAEBK100 Keypad XT diagnostic unit or through online diagnostics in EASY Starter.

Status LED Indicators

LEDColor/StatusMeaning
DRV-READYGreen - Solid / FlashingGreen: Drive operational and ready for operation. Flashing Green: Drive active / enabled.
DRV-BUSYYellow - SolidYellow: Parameter transfer or internal process active.
CAN-RUNGreen - SolidGreen: CANopen communication state is Operational.
CAN-ERRRed - SolidRed: CANopen bus error / bus off state.

Replacement and Spare Part Considerations

When replacing an existing Lenze E84AVTCE1524SX0 drive, physical and functional matching must be verified prior to power-up. Ensure the replacement unit shares the exact model number and rating (1.5 kW, 320–528 V AC input) to match line protection and motor specifications. If an MCI communication module (such as PROFINET, PROFIBUS, or EtherCAT) is installed on the existing drive, it must be transferred to the replacement unit's MCI slot to maintain control system communication.

To avoid manual re-parameterization, remove the pluggable EAM918 EEPROM memory module from the original drive and insert it into the replacement unit. This transfers the configured parameters, network node settings, and internal safety configuration automatically. After powering up the new drive, verify that the STO functional safety terminals are correctly wired and that communication status LEDs indicate normal operation on the system bus.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuitShort circuit at the output terminals or motor windingShort circuit in motor cable, winding connection, or power transistor stage faultCheck motor cable and motor windings for short circuit. If error persists without motor connected, replace the drive (internal power module failure).
OC5Overcurrent during accelerationMotor current exceeded acceleration threshold limitAcceleration time too short, motor overloaded, or defective motorIncrease acceleration time, check motor load and motor parameters.
OUOvervoltage DC busDC-bus voltage exceeded maximum allowable threshold limitExcessive regenerative energy during deceleration, deceleration time too short, or missing/defective brake resistorIncrease deceleration time, install brake chopper/resistor, or check mains supply voltage.
LUUndervoltage DC busDC-bus voltage fell below lower threshold limitMains supply voltage drop, phase failure, or blown input fuseCheck mains voltage, supply fuses, and power wiring.
OHHeatsink overtemperatureInverter heatsink temperature exceeded upper temperature limitInadequate control cabinet cooling, clogged fan, or ambient temperature too highClean heatsink/fan, check cabinet ventilation and ambient conditions.
OH4Motor overtemperature (PTC/TK)Motor temperature sensor reported excessive motor temperatureMotor thermal overload, blocked cooling air, or defective temperature sensor wiringAllow motor to cool, check motor load and PTC sensor connections.
CE0Communication faultCommunication interruption on system bus / fieldbus interfaceFieldbus cable disconnected, wrong baud rate, or missing termination resistorCheck fieldbus cabling, bus termination, and master controller status.
PIParameter set errorCorrupted or invalid parameter dataset stored in memory moduleIncompatible memory module or power interrupted during parameter savingReload default parameter settings or re-download parameters via EASY Starter.
H01Internal hardware errorControl board hardware self-test failureInternal electronic components failureInternal hardware fault — power cycle drive; if persistent, return unit for repair or replace device.

Frequently Asked Questions

How do I transfer drive parameters to a replacement Lenze E84AVTCE1524SX0?

Parameter sets can be transferred by moving the pluggable EAM918 EEPROM memory module from the original unit directly to the replacement drive. Alternatively, parameters can be uploaded and restored using Lenze EASY Starter or L-force Engineer software.

What feedback options are supported by the multi-encoder interface?

The onboard 15-pin Sub-D multi-encoder connector supports Resolvers, HTL, TTL, SinCos, and SSI absolute encoders.

Which fieldbus interfaces are compatible with the MCI extension slot?

The MCI slot accepts optional fieldbus cards including PROFINET (E84AYCER), PROFIBUS (E84AYCPM), and EtherCAT (E84AYCET), as well as EtherNet/IP and POWERLINK modules.

What does fault code H01 indicate on the 8400 TopLine C drive?

Fault code H01 indicates an internal hardware self-test failure on the control board. If cycling the input power does not clear the error, internal component damage is present, requiring repair or device replacement.

Does the E84AVTCE1524SX0 drive require an external safety relay for STO?

No. The inverter features integrated Safe Torque Off (STO) functional safety circuitry, which satisfies safety shutdown requirements without needing external safety relays.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.