Lenze E84AVTCE2224SB0 8400 TopLine C 2.2 kW Frequency Inverter
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze E84AVTCE2224SB0 is a 2.2 kW frequency inverter from the 8400 TopLine C series designed for dynamic multi-axis positioning and precise motion control applications. Operating on a three-phase supply range from 320 V AC to 528 V AC, this unit delivers a rated output current of 5.6 A and a maximum output current of 8.4 A. Output frequency is configurable from 0 Hz to 599 Hz with an 8 kHz default switching frequency. The drive supports multiple motor control modes, including V/f characteristic control, sensorless vector control, and full servo control for both asynchronous motors (SC-ASM) and permanent magnet synchronous motors (SC-PSM).
For networking and motor feedback, the drive includes an onboard CANopen system bus interface along with a multi-encoder port supporting resolvers, HTL, TTL, SinCos, and SSI feedback types. Broader control cabinet integration is enabled via an MCI extension slot that accepts fieldbus communication modules, including PROFINET (E84AYCER), PROFIBUS (E84AYCPM), and EtherCAT (E84AYCEC). Putting a replacement unit into service is straightforward: parameters can be transferred without software tools using the removable L-force Memory Module (E84AYMBM) inserted into slot X400, or via software using Lenze EASY Starter and Lenze Engineer. Integrated Safe Torque Off (STO) inputs provide functional safety directly on the drive.
Diagnostic monitoring is provided by four front-panel LEDs indicating drive status (DRIVE-READY, DRIVE-ERROR) and CANopen bus states (CAN-RUN, CAN-ERR). Fault events and operating parameters are recorded in an internal fault history buffer and system log. Initial troubleshooting should verify line input voltage, encoder cable connections, STO input signals, and proper seating of the MCI communication card or memory module. If the DRIVE-ERROR LED remains continuously illuminated red during internal self-testing, or if output short-circuit faults persist with no load connected, an internal hardware failure is present where tested exchange units or repair through ABC Industrial Parts can restore system operation.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | E84AVTCE2224SB0 |
| Model / Type | 8400 TopLine C |
| Component Type | Frequency Inverter |
| Rated Power | 2.2 kW |
| Supply Voltage Range | 320 - 528 V AC (3-phase) |
| Rated Output Current | 5.6 A |
| Max Output Current | 8.4 A |
| Output Frequency Range | 0 - 599 Hz |
| Default Switching Frequency | 8 kHz |
| Control Methods | V/f characteristic control, Sensorless Vector Control, Servo Control (SC-ASM, SC-PSM) |
| Digital Inputs | 8 |
| Digital Outputs | 4 |
| Relay Outputs | 1 |
| Analog Inputs | 2 |
| Analog Outputs | 2 |
| Integrated Safety | Safe Torque Off (STO) |
Programming and Configuration
Engineering and parameter adjustment for the Lenze E84AVTCE2224SB0 8400 TopLine C inverter are supported by Lenze EASY Starter and Lenze Engineer software (High-Tech / State-Tech versions). These engineering packages allow commissioning technicians to adjust motor parameters, speed ramps, controller dynamics, and feedback options for synchronous and asynchronous motors.
Hardware-based configuration storage is managed using the removable L-force Memory Module (E84AYMBM) fitted in slot X400. This plug-in module retains the complete unit parameter set, enabling rapid offline backup and configuration transfer. For direct cabinet-level parameter access and local control, the unit supports the optional L-force Keypad XT (E84AYKXR).
Communication and System Integration
The E84AVTCE2224SB0 drive features a built-in CANopen system bus interface for multi-axis coordination and distributed drive control. Position and velocity feedback are handled via the onboard multi-encoder port, which directly accepts resolvers, HTL, TTL, SinCos, and SSI encoders without external signal conditioning modules.
Network connectivity can be tailored to upper-level control architectures using optional MCI fieldbus modules installed in the extension slot. Supported options include PROFINET (E84AYCER), PROFIBUS (E84AYCPM), and EtherCAT (E84AYCEC). Direct machine control wiring is supported through physical I/O interfaces consisting of 8 digital inputs, 4 digital outputs, 1 relay output, 2 analog inputs, and 2 analog outputs.
Diagnostics and Status Indication
Four status LEDs on the drive front panel convey operational and bus state information. Drive readiness and fault statuses are reported by DRIVE-READY and DRIVE-ERROR LEDs, while system bus condition is shown by CAN-RUN and CAN-ERR LEDs.
Detailed troubleshooting is supported through an internal fault history buffer that stores recent fault events alongside operating parameters and timestamps. System events can also be read out through CANopen diagnostic objects or via a connected PC running Lenze EASY Starter.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| CAN-RUN | Green - Solid / Blinking / Single Flash | CANopen network status: ON = Operational, Blinking = Pre-Operational, Single Flash = Stopped |
| CAN-ERR | Red - Off / Single Flash / Double Flash / Solid | CANopen bus error: OFF = No error, Single Flash = Warning limit reached, Double Flash = Heartbeat/Guard event, ON = Bus off state |
| DRIVE-READY | Green - Solid / Blinking | Inverter operational readiness: ON = Inverter enabled / ready, Blinking = Inverter disabled / inhibit active |
| DRIVE-ERROR | Red - Blinking / Solid | Drive fault condition: Blinking = Warning active, ON = Trouble/Fault active (Inverter inhibited). Continuous red on internal self-test failure indicates hardware error requiring service. |
Replacement and Spare Part Considerations
Replacing an E84AVTCE2224SB0 drive can be accomplished quickly without software reprogramming by transferring the original L-force Memory Module (E84AYMBM) from slot X400 to the replacement unit. This transfers all user parameters, motor tuning settings, and fieldbus configurations directly upon power-up.
When swapping the unit, ensure that any installed MCI fieldbus module (such as PROFINET E84AYCER or PROFIBUS E84AYCPM) is transferred to the replacement drive's MCI slot and fully seated. Verify that the dual-channel Safe Torque Off (STO) circuit and motor encoder feedback wiring are reconnected correctly according to the machine wiring diagram prior to enabling the power stage.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| 0x0011 | Earth fault (EarthFault) | Earth fault / ground fault detected at output phase | Short circuit to earth in motor cable or motor winding | Check motor cable and motor windings for short circuit to ground. Replace motor or cable if insulation is damaged. |
| 0x0021 | Motor phase failure (MotorPhaseFail) | Failure of one or more output motor phases detected | Motor cable disconnected, phase wire loose, or motor winding interrupted | Check wiring between inverter and motor, check motor contactor if present. |
| 0x0030 | DC-bus overvoltage (OvervoltageDC) | DC bus voltage exceeded upper limit threshold | Excessive regenerative energy during deceleration, brake chopper inactive or brake resistor damaged/missing | Extend deceleration time, connect or check braking resistor, verify mains line supply voltage. |
| 0x0031 | DC-bus undervoltage (UndervoltageDC) | DC bus voltage fell below lower threshold | Mains supply power outage, mains voltage dip, phase failure on mains supply side | Verify line power supply voltage and fuses. |
| 0x0050 | Heatsink overtemperature (OvertempHeatsink) | Inverter heatsink temperature exceeds maximum safety limit | Cooling fan failed, air filter clogged, ambient temperature too high, or excessive continuous overload | Clean heatsink cooling fins, verify cooling fan operation, reduce load or ambient temperature. |
| 0x0051 | Inside overtemperature (OvertempInside) | Internal air temperature inside inverter housing exceeds safety limit | Inadequate control cabinet ventilation or cooling system failure | Improve control cabinet ventilation and airflow. |
| 0x0061 | Motor overtemperature (OvertempMotor) | Motor thermal sensor or PTC thermistor detected excessive motor temperature | Motor thermal overload, low speed operation without forced cooling fan, sensor wire interrupted | Allow motor to cool down, check motor load, check motor thermal sensor cable. |
| 0x0071 | Short circuit / Overcurrent (ShortCircuit) | Instantaneous overcurrent or phase-to-phase short circuit detected | Short circuit in output cable or motor, acceleration ramp time too short, motor incorrectly dimensioned | Check motor wiring and motor for inter-phase short circuit; extend acceleration time. Internal power stage damage — if fault persists without connected load, internal hardware failure requires repair/unit replacement. |
| 0x00A0 | CAN communication error (CANCommError) | CANopen system bus error or communication timeout | CAN bus cable broken, missing termination resistor, wrong baud rate, master node failure | Check CAN bus wiring, termination resistors (120 Ohm), and node ID/baud rate settings. |
| 0x00C0 | MCI module communication fault (MCICommFault) | Loss of communication between inverter control board and plugged MCI communication module | Loose module connector, fieldbus network fault, module defect | Re-seat communication module in MCI slot. If hardware failure persists, replace module. |
| 0x00D0 | Memory module fault (MemoryModuleFault) | Memory module missing, corrupted, or incompatible firmware version | Memory module removed during operation, invalid data formatting, corrupted EEPROM | Verify memory module is properly inserted in slot X400. Re-format or replace memory module if unrecoverable hardware fault. |
| 0x00E0 | Safety circuit fault (SafetyFault) | Safe Torque Off (STO) safety system channel mismatch or active safety error | Discrepancy between safety input channels, defective safety relay feedback, open STO circuit | Check STO safety dual-channel input wiring and safety switching device. Internal STO failure — return unit for service if internal safety circuit failed. |
Frequently Asked Questions
How do I transfer parameters to a replacement Lenze E84AVTCE2224SB0 inverter?
Parameters can be transferred without software tools by removing the L-force Memory Module (E84AYMBM) from slot X400 of the original unit and inserting it into slot X400 of the replacement drive. Alternatively, parameters can be uploaded and restored using Lenze EASY Starter or Lenze Engineer software.
Which motor feedback types are supported by this drive?
The onboard multi-encoder interface supports resolvers, HTL, TTL, SinCos, and SSI encoders for precise dynamic feedback control on synchronous and asynchronous motors.
How do I add PROFINET or PROFIBUS communication to the E84AVTCE2224SB0?
Fieldbus communication is added by inserting an optional MCI module into the extension slot, such as PROFINET E84AYCER, PROFIBUS E84AYCPM, or EtherCAT E84AYCEC.
What does a solid red DRIVE-ERROR LED mean?
A solid red DRIVE-ERROR LED indicates an active drive fault that inhibits output. If it stays lit continuously red during the startup self-test process, an internal hardware failure has occurred requiring repair or unit replacement.
What should I check if code 0x00E0 SafetyFault occurs?
Code 0x00E0 indicates a discrepancy or channel mismatch in the Safe Torque Off (STO) circuit. Check dual-channel STO input wiring and the safety relay output. If inputs are valid and the fault persists, internal safety circuit failure requires factory service.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.