Lenze EVF8201-E 8200 Vector 0.37 kW Frequency Inverter

Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze EVF8201-E is a compact 0.37 kW frequency inverter drive from the 8200 Vector series, engineered for speed and torque regulation of standard three-phase AC motors. Operating across a supply voltage range of 180 V to 264 V AC on single-phase or three-phase power lines, this panel-mounted drive provides a rated continuous output current of 2.4 A with an overload capacity up to 150% (3.6 A) for 60 seconds. Housed in an IP20 enclosure with a power dissipation rating of 35 W, the unit supports linear V/f, quadratic V/f, and high-torque sensorless vector control algorithms across an output frequency range of 0 to 480 Hz.
Integrating a replacement EVF8201-E into an existing control cabinet requires matching communication interfaces and transferring parameter configurations. The drive features a modular front interface slot accepting plug-in accessories such as the E82ZBC keypad operating module or dedicated fieldbus cards including PROFIBUS-DP (E82ZAFPC), CANopen (E82ZAFAC), DeviceNet (E82ZAFDC), and LECOM serial options (E82ZAFCC/E82ZAFSC). A spare unit requires parameter transferring; internal EEPROM memory holds four non-volatile parameter sets that must be backed up from the original unit and restored using the E82ZBC keypad or Lenze Global Drive Control (GDC) PC software V4.0+. Where parameter extraction from a damaged drive is difficult, ABC Industrial Parts offers expert technical support to assist with parameter recovery and matching replacement units.
Drive operation and diagnostic feedback are monitored via front-panel status LEDs and accessible memory parameters. A solid green OPER LED indicates active inverter operation driving the motor, while a flashing green signal highlights controller inhibit; a solid or flashing red TRIP / FAULT LED signals an active system trip. Active diagnostic status can be read via parameter P000, while historic fault events are logged in the P168 history buffer or inspected in the GDC oscilloscope workspace. Diagnostic messages like OC1, OU, or LU point to field wiring or supply issues, but hardware codes such as H05 or memory errors EE0/EER signal internal component failures. When internal hardware errors occur, sourcing a tested exchange unit or utilizing repair options through ABC Industrial Parts ensures a rapid return to full production.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | EVF8201-E |
| Model / Type | 8200 Vector 0.37 kW Frequency Inverter |
| Product Family | 8200 Vector |
| Component Type | Frequency Inverter Drive |
| Rated Power | 0.37 kW |
| Supply Voltage Range | 180 V AC - 264 V AC |
| Supply Phase | 1-Phase / 3-Phase |
| Rated Output Current | 2.4 A |
| Maximum Output Current | 3.6 A (150% for 60s) |
| Output Frequency Range | 0 - 480 Hz |
| Switching Frequency | 8 kHz |
| Power Dissipation | 35 W |
| Protection Rating | IP20 |
| Control Methods | Linear V/f, quadratic V/f, sensorless vector control |
Programming and Configuration
Parameter management on the Lenze EVF8201-E relies on four internal non-volatile EEPROM parameter sets. Direct commissioning, monitoring, and parameter adjustment can be executed without a PC by attaching the optional E82ZBC LCD keypad operating module to the front interface slot. The keypad enables full access to the parameter tree, enabling technicians to clone settings between identical drives or perform manual parameter adjustments directly at the cabinet.
For complete drive commissioning and automated parameter backup, the drive connects to a PC running Lenze Global Drive Control (GDC) software version 4.0 or higher. The GDC workspace provides parameter management tools and live tracing capabilities. When preparing a replacement drive or clearing unknown parameter settings, the inverter can be reset to factory default values by setting parameter P009 to 1 before loading the application-specific configuration.
Communication and System Integration
The modular construction of the EVF8201-E allows seamless integration into industrial network environments without changing the base power unit. The integrated front module slot accommodates interchangeable fieldbus interface cards to establish real-time communication with high-level automation controllers and PLCs.
Supported communication modules include PROFIBUS-DP (E82ZAFPC), CANopen (E82ZAFAC), DeviceNet (E82ZAFDC), and LECOM serial modules (E82ZAFCC / E82ZAFSC). When swapping drives during maintenance, the original communication module must be unclipped from the failed unit, installed into the replacement drive, and verified for correct node addressing, baud rate, and bus termination settings.
Diagnostics and Status Indication
The EVF8201-E offers multi-level diagnostic tools to simplify troubleshooting. Front-mounted status LEDs provide visual confirmation of active drive power and fault states. Detailed runtime status is monitored via parameter P000 on the optional keypad display, while parameter P168 retains an internal fault history log of prior trip conditions.
In addition to parameter codes, detailed signal analysis and oscilloscope diagnostics can be performed through the Lenze Global Drive Control software interface, allowing engineers to track speed curves, output currents, and bus voltages during operating cycles.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| OPER | Green - Solid / Flashing | Green Solid: Inverter enabled, motor running. Green Flashing: Inverter ready, controller inhibit active. |
| TRIP / FAULT | Red - Solid / Flashing | Fault condition present (Trip active). Persistent fault state indicates potential internal hardware error or external trip condition. |
Replacement and Spare Part Considerations
When replacing an EVF8201-E inverter, verify that the physical power specifications and mains voltage requirements match the application. The unit accepts single-phase or three-phase 180 V to 264 V AC inputs and delivers a continuous output of 2.4 A at 0.37 kW. Using a drive with incorrect electrical ratings can result in nuisance tripping or improper motor thermal protection.
Replacement drives must be configured with the application's parameter set before putting the equipment back into service. Parameter profiles must be restored from a backup or transferred using an E82ZBC keypad or Global Drive Control (GDC) PC software. Additionally, ensure that any plug-in fieldbus module (such as PROFIBUS E82ZAFPC or CANopen E82ZAFAC) is properly seated in the option slot and network parameters match the machine master configuration.
While the 8200 Vector series has been discontinued and replaced by the modern Lenze i510 and i550 series, direct replacement with a tested EVF8201-E unit avoids the downtime, mechanical cabinet modifications, and PLC re-programming associated with upgrading to a new inverter family.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short circuit / Overcurrent during acceleration | Output current exceeds threshold limit during acceleration phase. | Short circuit or earth fault at drive output, motor cable too long, acceleration time setting too short. | Check motor and output wiring for short circuits; increase acceleration time parameter. |
| OC2 | Overcurrent during deceleration | Output current exceeds threshold limit during deceleration phase. | Deceleration time setting too short, generatoric energy excess. | Increase deceleration time parameter or fit a braking module/resistor. |
| OC5 | Overcurrent during steady operation | Output current exceeds threshold limit during constant speed operation. | Sudden load impulse, motor overload, motor insulation fault. | Inspect mechanical load for binding/jamming; check motor winding insulation. |
| OU | DC bus overvoltage | Intermediate circuit DC bus voltage exceeds upper threshold limit. | Mains voltage too high, regenerative energy returned from motor during deceleration without brake chopper. | Check supply voltage; extend deceleration time or install braking resistor. |
| LU | DC bus undervoltage | Intermediate circuit DC bus voltage drops below lower threshold limit. | Supply mains voltage too low, line power supply drop or phase failure. | Check line mains voltage and input power fuses/connections. |
| OH | Heatsink overtemperature | Drive heatsink temperature exceeds maximum allowable threshold. | Insufficient cabinet ventilation, high ambient temperature, clogged heat sink fins. | Clean heat sink, improve enclosure air flow, reduce ambient temperature. |
| OH4 | Motor overtemperature | Motor temperature sensor (PTC or thermal contact) tripped. | Continuous motor overload, insufficient motor cooling, defective thermal sensor circuit. | Allow motor to cool down; inspect motor loading and external cooling fan. |
| OH7 | Internal drive overtemperature | Internal temperature inside inverter enclosure exceeds safety threshold. | Inadequate airflow around control board or severe internal load condition. | Improve enclosure cooling and ventilation. |
| OFL | Speed feedback loss / Motor slip fault | Motor speed slip or stall detected during operation. | Motor locked/jammed, extreme overload beyond motor maximum torque. | Check mechanical drive train for mechanical blockage; reduce load. |
| CE0 | Communication failure | Loss of communication between drive and option module / host system. | Loose fieldbus connection cable, network master timeout, improper baud rate. | Check communication module seat, bus cabling, and host master controller status. |
| EE0 | Internal EEPROM error | Internal parameter memory checksum or read/write error. | Corrupted EEPROM parameter memory, internal control board hardware fault. | Internal hardware/memory fault - reload factory default settings. If fault persists, unit requires return for repair or replacement. |
| EER | Memory read error | Failure reading parameter set from internal EEPROM. | Corrupted memory area or internal hardware issue. | Internal hardware fault - reload parameter set or replace unit. |
| Pr0 | Parameter set error | Incompatible parameter set or corrupted data during load sequence. | Parameter transfer attempted from incompatible drive power size or firmware version. | Re-initialize drive parameters to factory default setting (P009 = 1) and reconfigure manually. |
| H05 | Internal hardware failure | Control board self-diagnostic failure. | Internal component failure or power supply circuit malfunction. | Internal hardware fault - non-field-serviceable. Return drive for repair or replace the unit. |
| P12 | Analog input open-circuit | Signal loss on analog input set to 4..20 mA range. | Broken wire on analog input signal wire, missing master reference signal. | Check signal wire connections and 4..20 mA current transmitter source. |
Frequently Asked Questions
What control methods are supported by the Lenze EVF8201-E inverter?
The Lenze EVF8201-E supports linear V/f control, quadratic V/f control for fans and pumps, and high-torque sensorless vector control for demanding dynamic loads.
How do I transfer parameters from a faulty drive to a replacement EVF8201-E?
Parameters stored in internal EEPROM memory can be saved and transferred using an E82ZBC LCD keypad or uploaded and downloaded via Lenze Global Drive Control (GDC) software V4.0 or higher.
Which communication option modules fit the EVF8201-E front slot?
The front interface slot accepts PROFIBUS-DP (E82ZAFPC), CANopen (E82ZAFAC), DeviceNet (E82ZAFDC), and LECOM serial interface modules (E82ZAFCC / E82ZAFSC).
What does fault code H05 or EE0 indicate on the EVF8201-E display?
Fault code H05 indicates an internal control board hardware failure, while EE0 indicates internal EEPROM memory corruption. These internal component faults cannot be repaired in the field and require unit repair or replacement.
Which modern Lenze inverter series is the official replacement for the EVF8201-E?
Lenze recommends the i510 and i550 series frequency inverters as modern successors to the discontinued 8200 Vector series.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.