Lenze EVF8202-E-V002 8200 Vector Frequency Inverter 0.75kW 230V

New 
On request
Refurbished   
2 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 Series | Series: 8200 Vector

The Lenze EVF8202-E-V002 is a 0.75 kW (1.0 HP) variable speed frequency inverter belonging to the Lenze 8200 Vector product line within the 8200 Series. Designed for panel mounting in industrial control cabinets, this drive accepts a single-phase or three-phase mains input supply from 180 V to 264 V AC and delivers a 3-phase output voltage from 0 to 230 V AC with a rated continuous output current of 4.0 A and an output frequency range of 0 to 480 Hz. The V002 variant features an integrated radio interference suppression filter for built-in EMC compliance, eliminating the need for external filtering accessories while providing motor control through adjustable V/f characteristic curves or sensorless vector control.

For integration into automated machinery, the drive includes a modular Automation Interface (AIF) slot that accepts plug-in communication modules to link with higher-level control systems. Commissioning a replacement unit requires configuring the motor parameters and operational logic to match the existing machine setup. All four internal parameter sets can be downloaded or cloned using the XT Keypad E82ZBB001 or Lenze Global Drive Control (GDC) software, allowing a replacement drive to be prepared without re-engineering the control system. ABC Industrial Parts can assist maintenance teams with parameter extraction and drive configuration to ensure a smooth transition when installing a spare unit.

Diagnostic feedback is provided via an integrated dual-color status LED located on the drive, displaying operational states such as active operation, inhibited state, active faults, or warnings through solid or flashing green and red light patterns. Detailed diagnostics and error history codes, stored in internal code C0168, can be read using the XT Keypad, GDC software, or via a fieldbus status register. First-line troubleshooting for conditions such as overcurrent or bus voltage faults involves inspecting motor wiring, checking load mechanics, and verifying mains power. Internal memory errors or temperature sensor defects indicate hardware failures that are not field-serviceable, requiring unit repair or replacement through ABC Industrial Parts to restore production.

Technical Specifications

Rated Power0.75 kW
Supply Voltage Range180 - 264 V AC
Mains Input Phases1-phase / 3-phase
Rated Input Current9.0 A
Output Voltage0 - 230 V AC
Rated Output Current4.0 A
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz
Control MethodV/f Characteristic / Sensorless Vector Control
Power Loss45 W
Mounting TypePanel Mount
Integrated FilterRadio Interference Suppression Filter (V002)

Programming and Configuration

The Lenze EVF8202-E-V002 frequency inverter is configured using Lenze Global Drive Control (GDC) software or the optional XT Keypad E82ZBB001. Drive setup involves defining motor parameters, choosing between sensorless vector control and V/f characteristic control, configuring acceleration and deceleration ramps, and establishing overload protection thresholds.

The drive manages up to four internal parameter sets, enabling flexible operational profile switching for complex machinery. During drive maintenance or replacement, parameter sets can be cloned directly using the XT Keypad or saved and transferred electronically using GDC software. The internal parameter code C0168 maintains an active history log of diagnostic error codes to simplify operational troubleshooting and drive tuning.

Communication and System Integration

The EVF8202-E-V002 utilizes a modular architecture built around an integrated Automation Interface (AIF) slot. This interface physically separates the core 0.75 kW power processing hardware from fieldbus communication logic, allowing the drive to adapt to different network topologies without changing the base unit.

By installing Lenze E82ZAF series plug-in function and communication modules into the AIF slot, the drive connects directly to major industrial networks including CANopen, PROFIBUS-DP, DeviceNet, Modbus RTU, and InterBus. The pluggable module slot also enables drive status register readouts and control command transmission across the fieldbus network.

Diagnostics and Status Indication

Visual status indication is provided by a dual-color Ready / Fault LED on the front panel. Visual signals immediately indicate whether the drive is operational, in an inhibited state, experiencing a warning, or halted due to an active TRIP fault condition.

Extended diagnostics are accessible using the XT Keypad E82ZBB001 error code readouts or online monitoring with Lenze Global Drive Control (GDC) software. Fault codes logged in memory location C0168 supply real-time operational status and historical error data, while connected fieldbus interface modules expose drive status registers to supervisory controllers.

Status LED Indicators

LEDColor/StatusMeaning
Ready / Fault LEDGreen / Red - Solid Green / Flashing Green / Solid Red / Flashing RedGreen Solid: Drive operational; Green Flashing: Operation inhibited; Red Solid: Fault active (TRIP condition); Red Flashing: Warning active

Replacement and Spare Part Considerations

When replacing an EVF8202-E-V002 inverter, matching the exact part number ensures panel space compatibility and built-in EMC filter performance. The V002 designation indicates the inclusion of an integrated radio interference suppression filter, avoiding the need to install external noise suppression hardware in the cabinet.

Because the base drive is decoupled from fieldbus communications, existing E82ZAF series fieldbus modules can be transferred directly to the replacement unit via the Automation Interface slot. Prior to putting a replacement drive into operation, all four internal parameter sets must be loaded onto the unit using the XT Keypad E82ZBB001 or Global Drive Control software to align motor values, operational profiles, and network configurations.

As the Lenze 8200 Vector series has reached end-of-life status, direct replacement units remain the most effective solution for restoring operational availability without rewiring control cabinets. For future system redesigns or plant upgrades, Lenze recommends migrating to the i510 or i550 cabinet inverter series.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Overcurrent during accelerationOvercurrent detected in motor output during acceleration phase.Short circuit or earth fault on motor cable; acceleration time set too short; motor locked or overloaded.Check motor and output wiring for insulation failure; increase acceleration time; check motor mechanics.
OC2Overcurrent during decelerationOvercurrent detected in motor output during deceleration phase.Deceleration time set too short; excessive load inertia.Increase deceleration time; install or check braking resistor.
OC3Overcurrent at constant speedOvercurrent detected in motor output during constant speed operation.Sudden load impulse; mechanical blockage; motor undersized.Check motor load and mechanical system; verify drive capacity.
OC5I2t motor overloadCalculated motor thermal load exceeds maximum threshold.Continuous motor overload; improper motor data parameterization.Check motor operating current against rated motor current; check I2t parameter settings.
OUOvervoltage DC busIntermediate circuit DC bus voltage exceeds upper shutdown threshold.Mains voltage too high; regenerative energy from motor too high during braking; deceleration ramp too steep.Extend deceleration time; check mains voltage; install or check braking chopper and external resistor.
LUUndervoltage DC busIntermediate circuit DC bus voltage fell below lower shutdown threshold.Mains input supply failure; supply voltage too low; mains phase failure.Check mains voltage; check fuses and supply lines.
OHHeatsink overtemperatureInverter heatsink temperature exceeds limit.Ambient temperature too high; inadequate ventilation or fan failure; heatsink clogged.Clean heatsink fins; improve enclosure ventilation; check ambient temperature.
OH4Motor thermal overload (PTC)Motor temperature sensor connected to terminals T1/T2 activated.Motor overheating due to continuous overload or restricted motor cooling.Allow motor to cool down; check motor cooling fan and mechanical load.
OH7Heatsink temperature sensor faultInternal temperature sensor failure or open circuit.Internal temperature sensor broken or defective internal circuit.Internal hardware fault — return unit for repair.
EEREEPROM memory errorChecksum error reading non-volatile internal parameter memory.Internal EEPROM memory corruption or hardware defect.Internal hardware fault — perform parameter reset to default; if error persists, return unit for repair.
CE0Communication failure AIFCommunication interruption between inverter and plug-in automation module.Pluggable module loose or damaged; fieldbus network cable disconnected.Check module mechanical mounting; check fieldbus connection cable.
LP1Mains phase failurePhase failure detected on incoming mains supply.One input mains phase missing or blown fuse.Check incoming supply lines, fuses, and line contactor.

Frequently Asked Questions

How do I transfer parameters to a replacement Lenze EVF8202-E-V002 drive?

All four internal parameter sets can be cloned directly using the XT Keypad E82ZBB001 or transferred electronically using Lenze Global Drive Control (GDC) software.

What feature does the V002 designation indicate on this drive?

The V002 suffix specifies an integrated radio interference suppression filter (RFI/EMC filter) built directly into the unit to meet industrial noise standards without requiring external filter hardware.

Which fieldbus networks are supported by the EVF8202-E-V002?

Through its Automation Interface (AIF) slot and compatible Lenze E82ZAF series fieldbus modules, the drive supports CANopen, PROFIBUS-DP, DeviceNet, Modbus RTU, and InterBus protocols.

What does a solid red LED indicate on the EVF8202-E-V002?

A solid red LED indicates an active TRIP fault condition, which halts drive operation until the fault cause is cleared and reset.

What action should be taken if fault code EER or OH7 occurs?

Fault code EER indicates internal EEPROM memory error, while OH7 indicates a heatsink temperature sensor fault. Both represent non-field-serviceable internal hardware faults that require parameter resetting or sending the unit for repair.

What is the recommended modern replacement for the Lenze 8200 Vector series?

For new installations or machinery retrofits, Lenze recommends transitioning to the i510 or i550 cabinet inverter series.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.