Lenze EVF8211-E 8200 Series 0.75 kW Frequency Inverter

Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze EVF8211-E is a compact frequency inverter within the 8200 Series family, engineered for precise speed and torque control of three-phase AC motors rated at 0.75 kW. Operating on a 3-phase mains supply voltage of 400 V to 480 V AC (with an operating voltage range of 320 V to 550 V AC at 45 to 65 Hz), this drive delivers up to 2.4 A of continuous output current with a maximum output voltage of 480 V AC. Featuring an IP20 protection enclosure, the unit supports both linear or quadratic V/f characteristic control and sensorless vector control modes across an output frequency range of 0 to 480 Hz with an 8 kHz switching frequency.
Integrating a spare drive into an existing control system requires aligning drive parameters and network options to match the original application. The EVF8211-E features an integrated automation slot that accepts plug-in fieldbus extension cards—including the EMF2133IB PROFIBUS-DP, EMF2173IB CANopen, and LECOM modules—alongside the EMZ8201BB keypad operating module. Parameterization and commissioning can be managed using Lenze Global Drive Control (GDC) software or directly via the handheld keypad. Internal non-volatile EEPROM memory stores up to four complete parameter sets, allowing saved drive configurations to be transferred efficiently to replacement units to restore machine operation. ABC Industrial Parts can assist with sourcing compatible replacement units and parameter handling options.
Diagnostic information is made available directly on the front panel and through parameter registers. Dual status LEDs provide immediate feedback: a solid green LED indicates normal operation with the controller enabled, a blinking green LED signals ready status with controller inhibit active, and a solid red LED indicates an active TRIP fault state. When equipped with an EMZ8201BB keypad module, specific fault codes such as OC1 (short circuit), OU (DC bus overvoltage), or LU (undervoltage) are displayed, while historical trip data can be retrieved from parameter registers C0168 and C0170. If diagnostics point to internal board failures, such as internal thermal sensor fault OH7 or control hardware fault H05, board-level repairs or a fully tested exchange drive from ABC Industrial Parts provide a reliable path to resume production.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | EVF8211-E |
| Model / Type | EVF8211-E |
| Product Family | 8200 Series |
| Component Type | Frequency Inverter |
| Rated Power | 0.75 kW |
| Supply Voltage | 400 / 480 V AC (Range: 320 - 550 V AC) |
| Supply Frequency | 45 - 65 Hz |
| Continuous Output Current | 2.4 A |
| Max Output Voltage | 480 V AC |
| Output Frequency Range | 0 - 480 Hz |
| Switching Frequency | 8 kHz |
| Control Method | V/f Characteristic or Sensorless Vector Control |
| Protection Rating | IP20 |
Programming and Configuration
Drive setup and parameter management for the Lenze EVF8211-E are accomplished using Lenze Global Drive Control (GDC) engineering software or the plug-in EMZ8201BB keypad module. Parameters govern critical operational behaviors including acceleration and deceleration ramp times (parameters C0012 and C0013), motor current limits, and thermal monitoring settings such as parameter C0075 for I2t motor protection.
The inverter features non-volatile EEPROM memory capable of storing up to four complete parameter sets simultaneously. This multi-dataset architecture allows alternate operating configurations to be maintained within a single drive. During commissioning or unit replacement, stored configurations can be uploaded via GDC software or keypad modules to replicate original machine settings without requiring manual re-entry. Factory default settings can be restored when necessary by executing parameter reset code C0002=1.
Communication and System Integration
The EVF8211-E utilizes a modular communication interface centered around an integrated automation slot. This slot accepts dedicated fieldbus communication modules to integrate the inverter into higher-level industrial automation networks. Supported options include the EMF2133IB module for PROFIBUS-DP networks, the EMF2173IB module for CANopen fieldbus systems, and LECOM communication interfaces.
Network modules allow the drive to receive speed references, control commands, and enable signals directly from a master controller or PLC, while transmitting real-time operating data and fault conditions back to the network. When integrating a replacement drive onto a fieldbus, network station addresses, bus termination, and communication timeout parameters (monitored via communication trip code CE0) must be matched to the existing system architecture.
Diagnostics and Status Indication
The drive includes front-panel LED status indicators and parameter-based diagnostic monitoring tools. Visual indication is provided by status LEDs: the green LED shows operational readiness or active drive operation, while the red LED alerts operators to active TRIP conditions. Detailed diagnostic lookup is available through keypad module EMZ8201BB or software access to fault history memory registers C0168 and C0170.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Green LED (Ready / Operation) | Green - Solid / Blinking | Solid green indicates controller enabled and drive running; Blinking green indicates drive ready with power on and controller inhibit active. |
| Red LED (TRIP / Fault) | Red - Solid | Continuous red indicates an active TRIP fault state. |
Replacement and Spare Part Considerations
Replacing a legacy Lenze EVF8211-E 8200 Series inverter requires ensuring exact hardware identity and parameter replication. Because the EVF8211-E drives motor behavior based on application-specific parameter settings stored in memory, installing a replacement unit without transferring settings will result in improper drive behavior or fault conditions.
Before putting a spare drive into operation, transfer parameter sets from the original drive using the EMZ8201BB keypad memory transfer function or Global Drive Control (GDC) software. Fieldbus cards such as the EMF2133IB PROFIBUS-DP or EMF2173IB CANopen module must be moved from the original drive to the replacement unit or configured with identical node addresses and termination settings. Checking power connections, motor wiring insulation, and control terminal jumper settings prior to applying mains voltage prevents damage and ensures system compatibility.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short circuit | Short circuit on output terminal phases or ground fault during acceleration/operation | Short circuit in motor cable or motor windings; phase-to-phase insulation failure | Check motor wiring and insulation, test motor windings, check drive output terminals for shorts |
| OC2 | Earth fault / Ground fault | Earth current detected on output terminals | Ground fault in motor lead or motor frame; excessive capacitive earth leakage current in long motor cable | Check motor cable for damaged insulation, measure motor grounding insulation resistance |
| OC5 | Ixt overload | Drive current limit exceeded during acceleration or steady state | Excessive mechanical load; acceleration ramp time set too short; motor undersized | Increase acceleration time (parameter C0012), reduce load, check mechanical system for binding |
| OCH | Motor overload (I2t thermal monitoring) | Calculated thermal overload limit of motor exceeded | Continuous operation at high current at low motor speeds; improper I2t setting in parameter C0075 | Check motor current rating settings, allow motor to cool, verify cooling fan operation |
| OU | DC bus overvoltage | DC bus voltage exceeds maximum upper threshold level | Regenerative energy from driven load during deceleration; deceleration time set too fast; missing braking resistor | Increase deceleration time (parameter C0013), connect external braking module/resistor if installed |
| LU | DC bus undervoltage | DC bus voltage drops below lower operating threshold | Mains supply line drop, blown input fuse, phase loss, or power supply disconnection | Check mains input voltage levels, fuses, supply contactors, and input wiring |
| OH | Heatsink overtemperature | Drive internal heatsink temperature exceeded maximum safety threshold limit | Inadequate control cabinet ventilation, ambient temperature too high, dirty/clogged heatsink fins, internal fan failure | Clean heatsink, lower cabinet temperature, verify cabinet fan airflow, allow drive to cool |
| OH4 | Motor temperature sensor trip | Motor PTC or thermal switch connected to control terminals triggered trip state | Motor overheating due to overload or restricted cooling airflow | Check motor mechanical load and ventilation, verify PTC sensor terminal wiring |
| OH7 | Internal thermal sensor failure | Drive internal heatsink temperature sensor circuit open or shorted | Internal hardware failure on inverter power/control board | Internal hardware fault — requires service or return unit for repair |
| EER | EEPROM memory fault | Checksum fault or read/write error in internal EEPROM memory | Data corruption or internal non-volatile EEPROM chip failure | Perform parameter factory reset (C0002=1); if fault persists, internal board error requires unit repair or replacement |
| H05 | Internal control board hardware fault | Microprocessor or internal control board electronics fault | Internal hardware component failure or extreme electromagnetic interference | Internal hardware fault — power cycle drive; if fault persists, replace unit or contact repair service |
| CE0 | Communication timeout / error | Interruption in communication via automation slot or system interface | Loose cable connection, master PLC timed out, noise on communication line | Check fieldbus cable connections, termination resistors, and fieldbus master configuration |
Frequently Asked Questions
What software is used to program and configure the Lenze EVF8211-E?
Lenze Global Drive Control (GDC) software or the optional plug-in EMZ8201BB keypad operating module can be used to set parameters, adjust ramp times, and manage configuration files.
What do the status LEDs on the Lenze EVF8211-E indicate?
A solid green LED indicates the controller is enabled and the drive is running. A blinking green LED indicates power is on and the drive is ready with controller inhibit active. A solid red LED indicates an active TRIP fault condition.
How are parameter settings transferred to a replacement EVF8211-E drive?
Parameter sets stored in internal EEPROM memory (up to four complete sets) can be backed up and transferred using an EMZ8201BB keypad operating module or uploaded and downloaded using Lenze Global Drive Control (GDC) engineering software.
What fieldbus networks does the Lenze EVF8211-E support?
Through its integrated automation slot, the EVF8211-E supports optional communication modules including the EMF2133IB for PROFIBUS-DP, the EMF2173IB for CANopen, and LECOM interfaces.
What action should be taken if fault code H05 or OH7 is displayed?
Fault code H05 indicates an internal control board hardware fault, while code OH7 indicates an internal thermal sensor failure. Both point to internal hardware component issues that cannot be resolved through parameter adjustments and require unit repair or replacement.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.