Lenze EVF9330-EH 9300 Vector Frequency Inverter 75 kW 145 A

New 
On request
Refurbished   
2 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Vector | Series: 9300

The Lenze EVF9330-EH is a 75 kW vector frequency inverter from the 9300 Vector series, engineered to control speed and torque in heavy-duty three-phase AC motor applications. Operating across an AC supply range of 320 V to 528 V AC with a continuous output current rating of 145 A, this AC drive delivers adaptable motor control using sensorless vector control, closed-loop vector control, or V/f characteristic curves up to a maximum output frequency of 480 Hz. The -EH designation indicates an integrated radio interference suppression filter, which provides high EMC compliance without requiring separate external RFI filtering accessories in the cabinet panel layout.

Integrating a replacement EVF9330-EH unit into an existing machine requires matching communication setups and transferring stored drive configurations. The inverter features six digital inputs, four digital outputs, two analog inputs, and two analog outputs alongside an onboard CANopen system bus interface accessed via terminal X4. Optional fieldbus expansion modules—such as the EMF2133IB or EMF2131IB PROFIBUS-DP and EMF2173IB DeviceNet interfaces—can be swapped directly into the automation slot. Commissioning a replacement drive requires reloading the exact application parameters using either the pluggable EMZ9371BC keypad operating module or Lenze Global Drive Control (GDC) software. ABC Industrial Parts can support maintenance teams requiring tested spare units or assistance with parameter extraction from damaged non-volatile EEPROM memory.

Diagnostic conditions on the EVF9330-EH are identified via onboard status LEDs for RUN, TRIP, and Warning conditions, as well as diagnostic code readings on the EMZ9371BC keypad and parameter logs C0161 through C0170 in GDC software. Common application trips, such as overcurrent (OC1, OC2), DC bus overvoltage (OU), or motor overtemperature (OH3, OH7), often point to external issues like ground faults, tight acceleration ramps, or loose thermistor wiring on terminal X10. However, internal hardware errors such as H05 or internal power stage failures designated by PINT indicate hardware damage within the gate driver or control board that cannot be serviced in the field. Under these circumstances, replacing the unit or dispatching it for qualified hardware repair through ABC Industrial Parts is the fastest route to restoring production.

Technical Specifications

Rated Power Output75 kW
Minimum Supply Voltage320 V AC
Maximum Supply Voltage528 V AC
Rated Mains Current145 A
Continuous Output Current145 A
Minimum Output Frequency0 Hz
Maximum Output Frequency480 Hz
Switching Frequency8 kHz
Control MethodVector control / V/f characteristic control
Digital Inputs6
Digital Outputs4
Analog Inputs2
Analog Outputs2
Integrated System BusCANopen (CAN)
Radio Interference SuppressionIntegrated RFI Filter (-EH)

Programming and Configuration

Parameter management and drive commissioning on the Lenze EVF9330-EH are handled using Lenze Global Drive Control (GDC) software or the detachable EMZ9371BC keypad operating module. All operating parameters are stored in non-volatile internal EEPROM memory. The drive architecture supports four independent internal parameter sets, allowing operators to switch between pre-configured operational profiles during product changeovers without full re-commissioning.

When installing a replacement unit, drive parameter settings must be transferred to preserve precise motor control limits, I/O assignments, and fieldbus profiles. Parameters can be copied directly using the EMZ9371BC keypad memory function or downloaded via GDC software. If parameter data becomes corrupted or inconsistent, setting code C0002 to 1 resets the drive to factory default settings, allowing a clean upload of saved application files. Mismatched parameter sets or incomplete EEPROM writes trigger errors such as PR1 or EE, which require parameter re-loading before operation.

Communication and System Integration

The EVF9330-EH features an onboard CANopen system bus interface wired through terminal block X4. This integrated CAN interface allows high-speed system bus communication and cross-drive interlinking. To ensure reliable data transmission across the CAN bus network, terminal lines must be fitted with 120 ohm terminating resistors at both physical ends of the network loop.

For integration into broader industrial automation architecture, the inverter includes a modular expansion slot that accepts 2100 series communication modules. Compatible optional fieldbus hardware includes the EMF2133IB and EMF2131IB PROFIBUS-DP modules, the EMF2173IB DeviceNet module, and INTERBUS interface cards. Communication interruptions on these slots trigger specific diagnostics, such as CE0 for CANbus errors or CE1 for automation slot process data channel faults.

Diagnostics and Status Indication

Real-time operational feedback on the Lenze EVF9330-EH is provided through three status LEDs on the control board: RUN (Green), TRIP (Red), and Warning (Yellow). These LEDs indicate normal running states, active trip conditions, or operational limits such as current or torque boundaries. Comprehensive diagnostic monitoring is also accessible by plugging the EMZ9371BC keypad into the front interface or connecting GDC software to inspect system bus telegrams.

The drive maintains an internal history log spanning parameter codes C0161 through C0170. This fault memory records historical trip conditions to assist technicians in identifying intermittent application issues. Diagnostic views display detailed codes for overvoltage, ground leakage, motor overtemperature, and network timeout conditions.

Status LED Indicators

LEDColor/StatusMeaning
RUNGreen - Solid / FlashingDrive in normal operation mode
TRIPRed - Solid / FlashingDrive fault or trip condition detected
WarningYellow - Solid / FlashingDrive operating near current or torque limit

Replacement and Spare Part Considerations

When swapping a damaged drive for a replacement Lenze EVF9330-EH, confirm that the replacement matching part number contains the -EH suffix. The -EH designation indicates an integrated radio interference suppression filter; substituting a standard variant without internal filtering may lead to EMC non-compliance or require installing additional external panel filters.

Before applying power to the replacement drive, transfer any installed fieldbus cards (such as PROFIBUS EMF2133IB/EMF2131IB or DeviceNet EMF2173IB) into the expansion slot. Ensure motor PTC thermistor wiring is securely landed on terminal block X10 to prevent false OH3 or OH7 trip conditions, and verify that CANbus termination resistors are installed if terminal X4 is used.

Once physical installation is complete, load the matching parameter file from a backup copy via Global Drive Control (GDC) software or use the EMZ9371BC keypad to copy the parameter set. If an internal hardware error like H05 or PINT caused the original failure, repair of internal power boards or gate drivers is required as these faults cannot be cleared through parameter resets.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuit / OvercurrentInstantaneous overcurrent in the output power stageShort circuit between motor phases or earth fault, extremely fast acceleration ramp, damaged motor insulationCheck motor and motor cable for short circuit or earth fault; check acceleration time settings.
OC2Earth fault / Overcurrent during accelerationEarth fault or current threshold exceeded during motor accelerationGround leak in motor winding or cable, acceleration time too shortCheck motor insulation resistance, check wiring to ground, extend acceleration ramp.
OC5Drive overload (I x t)I x t overload threshold of the inverter reachedContinuous motor overload, drive underdimensioned for applicationReduce load on motor, check drive sizing, check mechanical binding.
OUDC bus overvoltageIntermediate circuit DC voltage exceeds maximum threshold limitBraking energy feedback too high during deceleration, deceleration ramp too short, mains supply voltage too highExtend deceleration time, install brake chopper and braking resistor, check supply AC voltage.
LUDC bus undervoltageIntermediate circuit DC voltage dropped below lower threshold limitMains voltage failure, input phase missing, mains supply voltage too lowCheck AC mains supply voltage, check fuses and main contactor.
OHHeat sink overtemperatureHeat sink temperature exceeded 90 °C limitCooling fan failed, air vents blocked, ambient temperature too high, heavy continuous overloadClean heat sink fins, replace internal fan if stopped, check cabinet ventilation.
OH3Motor overtemperatureMotor temperature sensor or PTC thermistor triggered overheat conditionMotor thermal overload, cooling fan on motor failed, PTC sensor cable brokenAllow motor to cool, verify thermal sensor wiring on terminal X10, check motor load.
OH4Inverter interior overtemperatureInternal cabinet / control board temperature inside inverter too highEnclosure ventilation insufficient, internal fan failureImprove enclosure cooling, inspect internal cabinet airflow.
OH7Motor temperature sensor open circuitWire break in motor temperature evaluation inputBroken cable or loose terminal connection at thermistor inputCheck wiring to thermistor / thermal sensor on terminals.
NMAXOverspeed / Maximum speed exceededActual motor speed exceeded configured maximum limitEncoder fault, gain settings incorrect in speed controller, overhauling loadCheck speed feedback sensor/encoder, verify PID speed controller parameters.
CE0System bus communication error (CAN)Interruption in communication over internal/external CAN system busBus wiring fault, bus termination missing, node offline or address conflictCheck CANbus connection terminals X4, verify 120 ohm terminating resistors, check baud rate.
CE1Process data input error 1Communication failure on automation module slot process data channel 1Fieldbus master stopped, communication cable broken, fieldbus module faultCheck fieldbus module connection, check master PLC status and cabling.
EEEEPROM memory errorInternal checksum error or memory corrupted during reading/writing parameter setPower failure during write cycle, corrupt EEPROM chip, internal hardware failureReload factory default settings (C0002 = 1); if fault persists, hardware repair or unit replacement required.
H05Internal hardware errorPower section or control board failure detected during internal diagnostic checkInternal board component failure, gate driver fault, internal supply errorInternal hardware fault — unit is not field-serviceable, return unit to Lenze for service or replace.
LP1Mains phase failureFailure of one line phase in the 3-phase AC inputBlown mains fuse, loose phase connection, heavy supply voltage imbalanceCheck input fuses and mains phase voltages under load.
PINTPower section internal errorCommunication fault or internal trip signal between power board and control boardInternal ribbon cable fault, defective power board or driver stageInternal hardware fault — board replacement or unit return required.
PR1Parameter set errorParameter set stored in EEPROM is invalid or inconsistentIncomplete transfer or mismatch between firmware versionsRestore factory default settings and re-commission drive.

Frequently Asked Questions

What software and accessories are used to configure the Lenze EVF9330-EH?

The EVF9330-EH is configured using Lenze Global Drive Control (GDC) software or directly via the pluggable EMZ9371BC keypad operating module, which allows parameter uploads, downloads, and status monitoring.

What does the -EH suffix mean on the EVF9330-EH inverter?

The -EH suffix indicates that the drive contains an integrated radio interference suppression (RFI) filter. This internal filter provides high EMC compliance without requiring external line filtering components.

How do I clear an EE or PR1 fault code on the EVF9330-EH?

EE and PR1 indicate EEPROM parameter corruption or invalid parameter sets. Reset the inverter to factory defaults by setting parameter code C0002 = 1, then reload the saved application parameter set using GDC software or the EMZ9371BC keypad.

Which fieldbus modules are compatible with the EVF9330-EH expansion slot?

The expansion slot supports 2100 series automation modules, including EMF2133IB and EMF2131IB PROFIBUS-DP cards, EMF2173IB DeviceNet modules, and INTERBUS fieldbus interfaces.

Can an H05 or PINT internal hardware fault be repaired in the field?

No. Fault codes H05 and PINT indicate internal control board, ribbon cable, or power stage component failures. These faults are not field-serviceable and require board-level hardware repair or complete drive replacement.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.