Lenze EVF9330-EVV004 EVF9330-EV V004 9300 Vector Frequency Inverter

New 
On request
Refurbished   
2 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Vector | Series: 9300 Series

The Lenze EVF9330-EVV004 is a panel-mounted frequency inverter from the 9300 Vector series, engineered for speed and torque control of three-phase AC motors in heavy-duty industrial applications. Operating from a supply voltage range of 400 V AC to 480 V AC (with operational supply limits between 320 V AC and 528 V AC), this drive delivers a continuous output current of 145 A and a rated input current of 140 A to support 75 kW motor loads. The inverter supports multiple control modes including V/f characteristic control, sensorless vector control, and closed-loop vector control with encoder feedback across an output frequency range of 0 to 480 Hz at a default 8 kHz switching frequency. Built as the V004 design variant, this unit is constructed without an internal RFI interference suppression filter, making it purpose-built for panel installations utilizing centralized EMC line filtering.

Integration into automated drive systems is provided by an onboard high-speed CAN system bus operating up to 500 kbit/s, alongside a 33-pin Automation Interface (AIF) slot. The AIF slot accepts expansion cards for fieldbus integration, including PROFIBUS-DP (EMF2133IB), CANopen (EMF2173IB), DeviceNet, and INTERBUS, or an RS232 LECOM-A adapter (EMF2101IB). Hardwired terminal interfaces include 5 digital inputs, 2 digital outputs, 2 analog inputs, and 2 analog outputs. Commissioning a replacement unit requires configuring parameters to match the motor and application settings, as up to four complete parameter sets can be stored in internal EEPROM memory. Parameter configuration and backup transfer can be performed using Lenze Global Drive Control (GDC) software or an optional XT Keypad (EMF2102IB). When replacing a faulty drive, extracting parameter sets directly from donor hardware with assistance from ABC Industrial Parts helps ensure correct parameters and bus addresses prior to restoring power.

Operational status and fault diagnostic feedback are provided via front-panel LEDs and status relay outputs on terminals K11, K12, and K14. The green READY LED blinks when the drive is ready and remains solid ON when the inverter is enabled and running, while the red TRIP LED remains solid during active fault conditions. Detailed diagnostic readouts and fault history codes stored in parameters C0168 and C0170 can be accessed via the XT Keypad or GDC diagnostic monitor. Common field trips include short circuits or overcurrent (OC1, OC2, OC5), DC bus voltage faults (OU, LU), heatsink and motor overtemperature (OH, OH3, OH4, OH7), phase failure (LP1), or fieldbus communications errors (CE0, CE1, CE2). Basic checks should verify input line voltages on L1, L2, L3, thermistor wiring on terminals T1 and T2, and 120 Ohm termination on CAN lines. When internal hardware faults such as H05 or system processor errors SYS occur, board-level failures cannot be serviced in the field, making tested exchange units or repair services through ABC Industrial Parts the most efficient path back to production.

Technical Specifications

ManufacturerLenze
Part NumberEVF9330-EVV004
Model / TypeEVF9330-EV V004
Product Family9300 Vector
Component TypeFrequency Inverter
Rated Power75 kW
Supply Voltage Range400 - 480 V AC
Minimum Supply Voltage320 V AC
Maximum Supply Voltage528 V AC
Rated Input Current140 A
Continuous Output Current145 A
Output Frequency Range0 - 480 Hz
Default Switching Frequency8 kHz
EMC Filter VariantV004 (Without internal RFI filter)
Digital Inputs5
Digital Outputs2
Analog Inputs2
Analog Outputs2
Mounting TypePanel Mount

Programming and Configuration

Configuring the Lenze EVF9330-EVV004 vector frequency inverter is performed using Lenze Global Drive Control (GDC) software or via the optional pluggable XT Keypad module (EMF2102IB). The drive incorporates internal EEPROM memory capable of holding up to four complete, independent parameter sets. This capability supports multi-mode operation or fast parameter set switching for specialized industrial tasks.

Parameterization defines motor parameters, control modes (V/f curve, sensorless vector, or closed-loop encoder control), ramp times, current limits, and fieldbus node parameters. Drive parameter sets stored in internal EEPROM can be saved, backed up, and uploaded using GDC software connected via a LECOM-A RS232 adapter (EMF2101IB) or directly transferred using the XT Keypad module.

Communication and System Integration

The EVF9330-EVV004 comes equipped with an integrated high-speed CAN system bus interface operating at bit rates up to 500 kbit/s. This system bus provides direct drive-to-drive cross-communication and synchronization in multi-axis machinery without placing additional load on higher-level fieldbus systems. Reliable CAN operation requires verified shielding, node address settings, and 120 Ohm termination resistors at both ends of the bus.

For integration into major fieldbus networks, the drive includes a 33-pin Automation Interface (AIF) slot. This interface supports option cards including PROFIBUS-DP (EMF2133IB), CANopen (EMF2173IB), DeviceNet, and INTERBUS modules. I/O connections feature 5 digital inputs, 2 digital outputs, 2 analog inputs, 2 analog outputs, and programmable status relays across terminals K11, K12, and K14.

Diagnostics and Status Indication

The drive provides continuous status and fault monitoring through front-panel LEDs, relay outputs, and internal status parameters. Physical relay outputs on terminals K11, K12, and K14 allow remote signaling of drive ready and trip conditions directly to a supervisory PLC interface.

Comprehensive diagnostic history can be evaluated using Lenze GDC software or the XT Keypad display. Current fault states and past trip history logs are recorded in parameters C0168 and C0170, enabling rapid identification of electrical, thermal, or communication issues.

Status LED Indicators

LEDColor/StatusMeaning
Red LED (TRIP)Red - SolidActive drive fault / Trip condition present
Green LED (READY)Green - Blinking / SolidBlinking: Drive ready for operation; Solid ON: Inverter enabled and running

Replacement and Spare Part Considerations

When selecting a replacement for the EVF9330-EVV004, ensure the V004 variant code is specifically matched. Because the V004 variant is manufactured without internal RFI suppression filtering, installing this drive into a cabinet without central EMC line filters will lead to non-compliance with noise emission standards and potential interference issues.

A replacement drive cannot be operated immediately out of the box without transferring configuration parameters. Before connecting to power and motor terminals, transfer all parameter sets stored in the internal EEPROM from the existing unit using Lenze GDC software or the XT Keypad module. Ensure motor control settings, encoder feedback configurations, and network settings (such as CAN node address or PROFIBUS slave addresses) are verified prior to commissioning.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuitShort circuit on output phases or motor windingShort circuit in motor or motor cable; excessive cable capacitance; motor cable length exceededCheck motor cable and motor for short circuit; verify motor cable length and cross section.
OC2Earth faultGround fault on output phaseEarth short circuit in motor or motor wiringCheck motor and motor cable insulation resistance to ground.
OC5Ixt overloadDrive output current overload (I x t integration limit exceeded)Excessive motor load; acceleration time too short; motor undersized for loadCheck drive loading; extend acceleration ramp time; verify motor sizing.
OUOvervoltage DC busDC bus voltage exceeded upper threshold limitExcessive regenerative energy during deceleration; deceleration ramp too short; missing brake resistorExtend deceleration time (dec ramp); install brake chopper/resistor; check mains supply voltage.
LUUndervoltage DC busDC bus voltage dropped below minimum operating limitMains supply voltage too low; main power failure; mains fuse blownCheck input mains voltage, input fuses, and power connections.
OHHeatsink overtemperaturePower section heatsink temperature exceeded 90 °C limitAmbient temperature too high; cooling fan failure; heatsink clogged or restricted airflowClean heatsink cooling fins; verify operation of internal fan; improve enclosure ventilation.
OH3Motor overtemperatureMotor thermistor sensor (PTC/TK) detected thermal overloadMotor thermal overload; insufficient motor cooling; PTC sensor cable brokenAllow motor to cool down; check motor load and cooling fan; check PTC connections on terminals T1, T2.
OH4Drive internal temperature warningInternal control board / enclosure temperature exceeded limitControl section environment too hotCheck cabinet ambient temperature and cooling system.
OH7Motor temperature sensor open circuitMotor temperature sensor circuit broken or disconnectedSensor wire broken or PTC terminals T1/T2 disconnectedCheck motor thermistor cable and connections.
LP1Mains phase failurePhase unbalance or loss of one input mains phaseBlown mains supply fuse; loose mains input phase conductorCheck supply lines L1, L2, L3 and upstream supply fuses.
CE0AIF communication errorCommunication interruption with module in AIF slotFieldbus communication module loose or fieldbus cable faultCheck fieldbus module seated properly in AIF slot and fieldbus cabling.
CE1System bus communication errorCAN system bus communication failureSystem bus cable fault; missing termination resistor; wrong baud rate settingCheck CAN wiring, terminal connections, and termination resistors (120 Ohm).
CE2System bus bus-off stateCAN controller entered Bus-Off state due to frame errorsExcessive noise on CAN bus cable; incorrect baud rate; loose shield connectionCheck CAN shielding, grounding, and node addresses.
EErExternal trip errorExternal fault triggered via digital inputDigital input configured for External Fault activated by external trip deviceCheck external fault circuit and connected monitoring devices.
H05Internal hardware faultInternal power or control card hardware failureInternal component degradation, power supply failure on control board, or memory errorInternal hardware fault — unit requires factory service or replacement.
SYSSystem faultProcessor or software system errorMicroprocessor program execution error or severe EMC interferencePower cycle drive; if fault persists, unit is defective and requires replacement.
NMAXMaximum speed exceededMotor speed exceeded parameter Nmax limitIncorrect speed controller parameters or overhauling loadCheck load dynamics and speed limit parameter settings.

Frequently Asked Questions

How are parameters transferred to a replacement EVF9330-EVV004 drive?

Parameter sets can be backed up and downloaded using Lenze Global Drive Control (GDC) software via a LECOM-A RS232 adapter (EMF2101IB), or transferred using the optional XT Keypad module (EMF2102IB). Up to four complete parameter sets are stored in the drive internal EEPROM.

What does the V004 designation signify in the EVF9330-EVV004 model number?

The V004 designation identifies the drive variant constructed without an internal RFI interference suppression filter. This variant is designed for installation in control cabinet systems that utilize dedicated central EMC line filtering.

What control modes does the EVF9330-EVV004 frequency inverter support?

The inverter supports standard V/f characteristic control, sensorless vector control, and closed-loop vector control with encoder feedback across an output frequency range of 0 to 480 Hz.

Which communication interfaces are available on the EVF9330-EVV004?

The unit features an integrated CAN system bus operating up to 500 kbit/s and a 33-pin Automation Interface (AIF) slot supporting optional modules for PROFIBUS-DP (EMF2133IB), CANopen (EMF2173IB), DeviceNet, and INTERBUS.

What does a solid red TRIP LED indicate on the front panel?

A solid red TRIP LED indicates an active drive trip or fault condition. Specific active fault codes and trip history can be reviewed in parameters C0168 and C0170 using the XT Keypad or GDC software.

What action is required if fault code H05 or SYS appears on the drive?

Fault codes H05 (internal hardware fault) and SYS (processor/system fault) indicate internal power or control card failures. These internal hardware faults are not field-serviceable and require drive replacement or specialized repair.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.