Lenze EVS9326-EIV907 9300 Servo PLC Controller 11 kW

New 
On request
Refurbished   
10+ available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo | Series: 9300

The Lenze EVS9326-EIV907 is an 11 kW panel-mount servo controller from the 9300 Servo PLC family, designed to combine motion control and programmable logic inside a single IP20 housing. Operating on a 3-phase AC supply voltage between 320 V and 528 V AC, the drive delivers a continuous output current of 23.5 A at an 8 kHz switching frequency and supports a 150% peak current overload of 35.3 A for up to 60 seconds. By incorporating an IEC 61131-3 compliant internal PLC directly into the inverter structure, the EVS9326-EI V907 handles multi-axis positioning, synchronized web processing, and dynamic packaging automation without requiring separate central controller hardware.

Interfacing the unit into a machine control architecture involves standard terminal connections alongside dedicated feedback ports, including Sub-D connectors for resolver and master incremental encoder inputs, as well as 8 digital inputs, 4 digital outputs, 2 bipolar analog inputs, and 2 bipolar analog outputs. High-speed inter-drive network traffic is supported over an onboard CANopen system bus via terminal strip X14 at speeds up to 500 kbps, while an Automation Interface (AIF) slot accommodates optional fieldbus modules such as the EMF2133IB PROFIBUS-DP module. Commissioning a replacement unit requires restoring the parameter settings—up to four complete parameter sets can be stored in internal memory—and reloading the compiled PLC program code developed in Drive PLC Developer Studio (DDS) using Global Drive Control (GDC) software or an EMF2102IB Keypad XT operator module. Where existing files are unavailable, technical teams at ABC Industrial Parts can assist in extracting configuration data from a damaged unit to ensure identical motion profiles and parameter alignment on the replacement drive.

Real-time diagnostic feedback is provided by three front-panel status LEDs, indicating drive ready status with a solid green DRV-READY light, pulse inhibit via a yellow IMP light, and active fault conditions with a red DRV-ERR light. System diagnostics can also be interrogated through the optional Keypad XT module, CANopen status registers, or live monitoring in GDC and DDS software environments. Fault codes such as LU (DC bus undervoltage), OU (DC bus overvoltage), OH (heatsink overtemperature), and OC1 (acceleration overcurrent) indicate external power line, thermal, or wiring anomalies that can be resolved by checking supply voltages, cabinet ventilation, and motor cabling. Communication errors like CE0 or CE1 highlight CAN termination or AIF option module seating issues, whereas internal diagnostic codes like H05 hardware faults or persistent EEr memory errors signal board-level issues that are not field-serviceable. In these instances, obtaining a tested replacement unit or utilizing repair services through ABC Industrial Parts provides a rapid resolution to restore machine operation.

Technical Specifications

ManufacturerLenze
Part NumberEVS9326-EIV907
Model / TypeEVS9326-EI V907
Product Family9300 Servo
Component TypeServo Controller
Rated Power11 kW
Supply Voltage Range320 - 528 V AC (3-phase)
Continuous Output Current23.5 A
Maximum Output Current35.3 A
Switching Frequency8 kHz
Digital Inputs8 (24 V DC)
Digital Outputs4
Analog Inputs2 (bipolar)
Analog Outputs2 (bipolar)
Ingress Protection RatingIP20
System Bus InterfaceOnboard CANopen (terminal strip X14, up to 500 kbps)
Feedback InterfacesResolver (Sub-D X7) and Master Incremental Encoder

Programming and Configuration

The Lenze EVS9326-EIV907 combines logic execution and servo control through an integrated IEC 61131-3 compliant Drive PLC. Engineering and application development are executed using Lenze Drive PLC Developer Studio (DDS) software, which allows custom application code, positioning tasks, and logic routines to be written and compiled directly for the controller runtime environment. Drive commissioning, standard parameter assignment, and real-time trace functions are performed via Global Drive Control (GDC) software connected through a PC System Bus Adapter such as the EMF2177IB or EMF2173IB.

The controller features internal non-volatile memory capable of retaining up to four distinct parameter sets along with the compiled DDS logic program. Parameters can be copied, edited, and saved using the optional EMF2102IB Keypad XT operator module plugged directly into the drive interface slot, allowing fast field parameterization without requiring a laptop connection.

When replacing a unit in production, both the parameter sets and the DDS application project code must be restored to match the physical machine configuration. If a PR0 fault code appears during operation, it indicates a runtime logic error inside the internal PLC code, requiring application engineers to connect via DDS, debug the runtime exception, and re-download the corrected project code to the drive memory.

Communication and System Integration

System integration for the EVS9326-EIV907 is facilitated through an integrated CANopen system bus interface accessible on terminal strip X14. Operating at transmission rates up to 500 kbps, this system bus enables fast inter-drive synchronization, multi-axis master-slave arrangements, and direct peer-to-peer data interchange across complex automated machinery. Proper network layout requires standard 120-ohm termination resistors at each physical end of the CAN network.

For broader factory automation networks, the drive includes a pluggable Automation Interface (AIF) slot designed for fieldbus communication modules. Installing an optional EMF2133IB module enables direct connectivity to PROFIBUS-DP networks, while alternative option modules allow integration into DeviceNet or INTERBUS control systems. These modules interface directly with the internal drive control registers and PLC runtime variables.

Physical signal integration is handled through terminal connections providing 8 freely programmable 24 V DC digital inputs, 4 digital outputs, 2 bipolar analog inputs, and 2 bipolar analog outputs. Closed-loop position and velocity feedback connections are provided via dedicated Sub-D connectors, supporting standard resolver feedback on connector X7 as well as master incremental encoder inputs.

Diagnostics and Status Indication

The EVS9326-EIV907 provides clear visual and digital diagnostic feedback to simplify troubleshooting during installation and normal operation. The front cover features three status LEDs that immediately show the operational status of the power stage, logic runtime, and fault conditions. Detailed status registers and error history logs are accessible over the CANopen bus or through the online diagnostic monitor within Global Drive Control (GDC) and Drive PLC Developer Studio (DDS) software.

When fitted with an optional EMF2102IB Keypad XT module, specific diagnostic codes and error messages are rendered directly on the display. In addition to monitoring real-time operating variables like DC bus voltage and motor speed, the keypad displays clear error codes when fault conditions trip the drive's protective functions.

Status LED Indicators

LEDColor/StatusMeaning
DRV-ERRRed - Solid/FlashingFault state / Active error present in the controller
DRV-READYGreen - SolidController ready for operation / Inverter enabled
IMPYellow - SolidPulse inhibit active (power stage disabled)

Replacement and Spare Part Considerations

When substituting an existing drive with a replacement Lenze EVS9326-EIV907 unit, verification of both hardware model type and power ratings is critical. The replacement drive must match the EVS9326-EI V907 designation to guarantee compatibility with the 11 kW output stage, 23.5 A continuous output current rating, and 320–528 V AC input supply range.

Because the unit integrates an onboard PLC, a bare replacement drive will not operate in the machine until both the device parameters and the IEC 61131-3 logic program are downloaded. Any optional fieldbus cards, such as the EMF2133IB PROFIBUS-DP module, must be transferred from the original unit to the replacement drive's AIF slot, ensuring address settings and bus wiring match the host network master configuration.

Before restoring power to the replacement unit, verify proper grounding and cable shield connections on resolver input X7 and motor power terminals. Ensure that line voltage levels are within limits and verify that the 120-ohm CAN bus termination resistors are correctly engaged on terminal strip X14 if the drive forms part of a multi-axis system bus topology.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OHHeatsink OvertemperatureController heatsink temperature exceeded maximum thresholdInadequate cooling, fan failure, ambient temperature too high, continuous overloadCheck cabinet ventilation, clean heatsink, check cabinet fans and duty cycle
OH4Motor OvertemperatureMotor temperature sensor trip (PTC or thermal contact input)Motor overloaded, cooling fan on motor failed, sensor wire brokenAllow motor to cool down, inspect motor fan and load conditions
LUUndervoltage DC BusDC bus voltage dropped below minimum operating limitMains supply interrupted, line phase failure, supply voltage too lowCheck AC line supply voltage and input fuses
OUOvervoltage DC BusDC bus voltage exceeded maximum allowable thresholdExcessive regenerative energy during deceleration, brake chopper resistor disconnected or faultyIncrease deceleration time, check external braking resistor and braking transistor
OC1Short Circuit / Overcurrent AccelerationShort circuit or extreme overcurrent during acceleration phaseMotor cable short circuit, ground fault, acceleration time too short, motor stallCheck motor wiring and insulation, test motor for winding short circuit, increase acceleration ramp time
OC2Short Circuit / Overcurrent DecelerationShort circuit or peak overcurrent during decelerationDeceleration ramp too short, motor cable insulation faultIncrease deceleration ramp time, check motor and output cables
OC5I x t OverloadContinuous overload threshold reached for controller output stageDrive undersized for mechanical load, mechanical bindingCheck load mechanics for binding, verify motor and drive sizing
CE0System Bus Communication ErrorCAN system bus communication failure or bus offCAN bus wiring fault, missing bus termination resistor, wrong baud rate settingInspect CAN wiring, check 120 ohm termination resistors and baud rate settings
CE1AIF Communication FaultCommunication failure with module installed in Automation Interface slotFieldbus communication timeout, bad connector, module unseatedRe-seat option module, check fieldbus cabling and master controller status
EErEEPROM FaultChecksum fault when accessing internal parameter memoryInternal EEPROM failure or corrupted parametersReload factory parameters. Internal hardware failure — return unit for repair if fault persists.
H05Internal Hardware FaultPower board or control board internal diagnostic errorInternal electronic failureInternal hardware fault — return unit for repair
NMAXSpeed Limit ExceededActual motor speed exceeded maximum configured velocity limitSpeed loop instability, encoder wiring fault, runaway loadCheck feedback sensor signals, verify gain settings in speed controller
PR0PLC Program FaultRuntime error or crash in internal Drive PLC application codeDivide by zero, invalid pointer, cycle time overflow in DDS program codeCheck DDS application project code and download corrected PLC application
P12Resolver Signal ErrorFault detected in resolver feedback signalResolver cable damaged, loose plug at X7, bad resolver sensorCheck resolver connection cable and shield grounding
P13Resolver Open CircuitBroken wire / signal loss on resolver connectionFeedback cable disconnected or severedInspect X7 terminal cable for continuity and correct wiring

Frequently Asked Questions

What software is required to program and configure the Lenze EVS9326-EIV907?

Drive commissioning and parameter setup are handled using Global Drive Control (GDC) software, while the integrated IEC 61131-3 PLC application is created, compiled, and downloaded using Drive PLC Developer Studio (DDS) software. Parameter adjustments can also be made directly using the optional EMF2102IB Keypad XT module.

How do I transfer parameters and programs to a spare EVS9326-EIV907 drive?

Parameters and compiled PLC code can be downloaded from a PC running GDC and DDS software using an EMF2177IB or EMF2173IB PC System Bus Adapter connected to the CAN system bus. Alternatively, individual parameter sets can be copied and transferred using an EMF2102IB Keypad XT operator module.

What causes a PR0 fault code on the EVS9326-EIV907?

A PR0 fault code indicates a runtime exception or crash in the internal Drive PLC application code, such as an arithmetic overflow or program cycle timeout. Resolving this requires connecting with Drive PLC Developer Studio (DDS), debugging the application logic, and downloading the corrected project code.

What external option modules are supported for fieldbus communication?

The EVS9326-EIV907 features a pluggable Automation Interface (AIF) slot that supports option modules such as the EMF2133IB PROFIBUS-DP module, as well as DeviceNet and INTERBUS communication cards.

What does the yellow IMP LED indicate on the front panel?

A solid yellow IMP LED indicates that pulse inhibit is active, meaning the controller output stage is disabled and no voltage is being delivered to the motor terminals.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.